Stéphane Elkouri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stéphane Elkouri has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
Jean-François Blair
11 shared publicationsNathalie Beaudoin
9 shared publicationsLaura M. Drudi
6 shared publicationsPhilippe Charbonneau
4 shared publicationsLuc Bruneau
Service de chirurgie vasculaire, Centre hospitalier de l’université de Montréal, Hôtel-Dieu, Montreal, Canada
3 shared publications- Philippe Charbonneau
Centre Hospitalier de l'Université de Montreal (CHUM) Aortic Center, Montreal, QC, Canada; Division of Vascular Surgery, CHUM, Montreal, QC, Canada
3 shared publications
Latest Publications
- Open Access
- 14 August 2026
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (6)
Ruptured thoracoabdominal aortic aneurysm treated with physician-modified endograft and in situ laser fenestrations to limit aortic coverage
- 14 August 2026
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (6)
Open AccessRuptured thoracoabdominal aortic aneurysm treated with physician-modified endograft and in situ laser fenestrations to limit aortic coverage
- Open Access
- 5 May 2026
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (4) , 102275
Endovascular repair of a type IA endoleak following ALTO endograft placement using a custom-made fenestrated device
- 5 May 2026
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (4) , 102275
Open AccessEndovascular repair of a type IA endoleak following ALTO endograft placement using a custom-made fenestrated device
- 13 October 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (1) , 385-399
High-fidelity virtual endovascular aneurysm repair model as a decision-making tool
Endovascular aneurysm repair (EVAR) is associated with favorable short-term outcomes; however, its long-term durability can be enhanced through effective decision-making tools. Currently, most clinical decision-making relies on pre-operative CT imaging that does not fully account for vascular deformation or endovascular device behavior. To address this limitation, we present a high-fidelity virtual EVAR model designed to predict procedural outcomes and optimize treatment planning. We used only patient imaging data to reconstruct tissue structures, preserving a non-invasive workflow. Finite element simulations captured the crimping of stent grafts (SGs), navigation of endovascular devices, and SG implantation. Deformation and stored energy were continuously tracked at each procedural step. We validated the model’s results against post-operative CT data using an image fusion technique. Compared to the patient’s post-operative data, the model showed strong alignment, with a mean modified Hausdorff distance of 1.71 ± 1.40 mm between the simulated and actual lumen centerlines. Additionally, the 1.65 ± 1.13 mm lumen radius error further supports the model’s validity. This high-fidelity, automated, and cost-effective framework can serve as a complementary tool for current EVAR pre-planning practices, potentially improving device selection, streamlining navigation roadmaps, reducing complications, and ultimately enhancing patient outcomes.
- 13 October 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (1) , 385-399
High-fidelity virtual endovascular aneurysm repair model as a decision-making tool
Endovascular aneurysm repair (EVAR) is associated with favorable short-term outcomes; however, its long-term durability can be enhanced through effective decision-making tools. Currently, most clinical decision-making relies on pre-operative CT imaging that does not fully account for vascular deformation or endovascular device behavior. To address this limitation, we present a high-fidelity virtual EVAR model designed to predict procedural outcomes and optimize treatment planning. We used only patient imaging data to reconstruct tissue structures, preserving a non-invasive workflow. Finite element simulations captured the crimping of stent grafts (SGs), navigation of endovascular devices, and SG implantation. Deformation and stored energy were continuously tracked at each procedural step. We validated the model’s results against post-operative CT data using an image fusion technique. Compared to the patient’s post-operative data, the model showed strong alignment, with a mean modified Hausdorff distance of 1.71 ± 1.40 mm between the simulated and actual lumen centerlines. Additionally, the 1.65 ± 1.13 mm lumen radius error further supports the model’s validity. This high-fidelity, automated, and cost-effective framework can serve as a complementary tool for current EVAR pre-planning practices, potentially improving device selection, streamlining navigation roadmaps, reducing complications, and ultimately enhancing patient outcomes.
- Open Access
- 4 April 2025
- Published by Elsevier in JVS-Vascular Insights
- Vol. 3
Moderate risk of all-cause mortality and stent-related complications in patients undergoing endovascular treatment for chronic mesenteric ischemia
- 4 April 2025
- Published by Elsevier in JVS-Vascular Insights
- Vol. 3
Open AccessModerate risk of all-cause mortality and stent-related complications in patients undergoing endovascular treatment for chronic mesenteric ischemia
- 23 January 2025
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 113, 205-213
Time Until Operation for Elective Endovascular Aortic Aneurysm Repair in Canadian Vascular Centers Using the Canadian Vascular Quality Initiative Registry
- 23 January 2025
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 113, 205-213
Time Until Operation for Elective Endovascular Aortic Aneurysm Repair in Canadian Vascular Centers Using the Canadian Vascular Quality Initiative Registry
- 22 August 2024
- Published by Elsevier in Journal of Surgical Research
- Vol. 302, 555-560
Exploring the Acceptable Delay for Elective Treatment of Patients With an Abdominal Aortic Aneurysm: A Reflection During a Pandemic and an Exploratory Analysis
- 22 August 2024
- Published by Elsevier in Journal of Surgical Research
- Vol. 302, 555-560
Exploring the Acceptable Delay for Elective Treatment of Patients With an Abdominal Aortic Aneurysm: A Reflection During a Pandemic and an Exploratory Analysis
- Open Access
- 20 July 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 68 (6) , 695-702
Editor's Choice – Safety of Shunting Strategies During Carotid Endarterectomy: A Vascular Quality Initiative Data Analysis
- 20 July 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 68 (6) , 695-702
Open AccessEditor's Choice – Safety of Shunting Strategies During Carotid Endarterectomy: A Vascular Quality Initiative Data Analysis
- Open Access
- 8 January 2024
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 40 (1) , 1
Inverted Ovation iX Limb to Treat an Isolated Common Iliac Artery Aneurysm
Said Ashkar, Philippe Charbonneau, and Stephane Elkouri. Vasc Specialist Int 2024;40:. https://doi.org/10.5758/vsi.230086
- 8 January 2024
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 40 (1) , 1
Open AccessInverted Ovation iX Limb to Treat an Isolated Common Iliac Artery Aneurysm
Said Ashkar, Philippe Charbonneau, and Stephane Elkouri. Vasc Specialist Int 2024;40:. https://doi.org/10.5758/vsi.230086
- Open Access
- 3 November 2023
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 10 (1) , 101364
A mycotic aneurysm of a jejunal branch treated by aneurysmectomy without bowel resection
- 3 November 2023
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 10 (1) , 101364
Open AccessA mycotic aneurysm of a jejunal branch treated by aneurysmectomy without bowel resection
- 21 April 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (1) , 251-258
Treating a Large Thoracoabdominal Aneurysm With Aberrant Right Subclavian Artery With a Physician-Modified Graft
We report the treatment of a young patient with Loeys-Dietz syndrome and previous type A aortic dissection repair and extensive thoracoabdominal aortic aneurysm using an aberrant right subclavian as inflow for debranching of the aortic arch. Clinical Impact: Large thoracoabdominal aortic aneurysms due to chronic aortic dissection in patients with connective tissue disorders such as Loeys-Dietz syndrome present a challenging scenario, particularly in cases of variant anatomy and when patients are not candidates for conventional open repair. We demonstrate how by combining and modifying off-the-shelf devices during a hybrid procedure, one can create an endovascular solution tailored to the patient’s complex anatomy, making use of an aberrant right subclavian artery, and allow for good clinical outcomes
- 21 April 2023
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (1) , 251-258
Treating a Large Thoracoabdominal Aneurysm With Aberrant Right Subclavian Artery With a Physician-Modified Graft
We report the treatment of a young patient with Loeys-Dietz syndrome and previous type A aortic dissection repair and extensive thoracoabdominal aortic aneurysm using an aberrant right subclavian as inflow for debranching of the aortic arch. Clinical Impact: Large thoracoabdominal aortic aneurysms due to chronic aortic dissection in patients with connective tissue disorders such as Loeys-Dietz syndrome present a challenging scenario, particularly in cases of variant anatomy and when patients are not candidates for conventional open repair. We demonstrate how by combining and modifying off-the-shelf devices during a hybrid procedure, one can create an endovascular solution tailored to the patient’s complex anatomy, making use of an aberrant right subclavian artery, and allow for good clinical outcomes