CBChristine M. Bachman

Christine M. Bachman

*This is an algorithmically generated author record based on publicly available information.

Christine M. Bachman has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    New Manual Quantitative Polymerase Chain Reaction Assay Validated on Tongue Swabs Collected and Processed in Uganda Shows Sensitivity That Rivals Sputum-based Molecular Tuberculosis Diagnostics

    by Amy Steadman, Alfred Andama, Alexey Ball, Job Mukwatamundu, Khushboo Khimani, Tessa Mochizuki, Lucy Asege, Alice Bukirwa, John Baptist Kato, David Katumba, et al.

    Background: Sputum-based testing is a barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce sputum, and sputum processing increases assay complexity and cost. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at 2 health centers in Kampala, Uganda. We collected demographic and clinical information, sputum for TB testing (Xpert MTB/RIF Ultra and 2 liquid cultures), and tongue swabs for same-day quantitative polymerase chain reaction (qPCR) testing. We evaluated tongue swab qPCR diagnostic accuracy versus sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared 2 swab types (Copan FLOQSWAB and Steripack spun polyester). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were diagnosed with human immunodeficiency virus, and 32.0% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% (95% confidence interval [CI]: 96.2–99.1) of participants. Tongue swab qPCR sensitivity was 92.6% (95% CI: 86.5 to 96.0) and specificity was 99.1% (95% CI: 96.9 to 99.8) versus microbiological reference standard. A single tongue swab recovered a 7-log range of TB copies, with a decreasing recovery trend among 4 serial swabs. Swab types performed equivalently. Conclusions: Tongue swabs are a promising alternative to sputum for molecular diagnosis of TB, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab–based TB diagnostics.


  • Open Access

    New manual qPCR assay validated on tongue swabs collected and processed in Uganda shows sensitivity that rivals sputum-based molecular TB diagnostics

    by Amy Steadman, Alfred Andama, Alexey Ball, Job Mukwatamundu, Khushboo Khimani, Tessa Mochizuki, Lucy Asege, Alice Bukirwa, John Baptist Kato, David Katumba, et al.

    Background: Reliance on sputum-based testing is a key barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce and sputum processing increases the complexity and cost of molecular assays. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at two health centers in Kampala, Uganda. We collected routine demographic and clinical information, sputum for routine TB testing (one Xpert MTB/RIF Ultra® and two liquid cultures), and up to four tongue swabs for same-day qPCR. We evaluated tongue swab qPCR diagnostic accuracy in reference to sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared two swab types (Copan FLOQSWAB® and Steripack® spun polyester swabs). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were living with HIV (PLHIV) and 32.3% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% [96.2-99.1] of participants. Tongue swab qPCR sensitivity was 91.0% [84.6-94.9] and specificity 98.9% [96.2-99.8] vs. microbiological reference standard (MRS). A single tongue swab recovered a seven-log range of TB copies, with a decreasing recovery trend among four serial swabs. We found no difference between swab types. Conclusions: Tongue swabs show promise as an alternative to sputum for TB diagnosis, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.


  • Open Access

    Plasmodium falciparum serology: A comparison of two protein production methods for analysis of antibody responses by protein microarray

    by Tate Oulton, Joshua Obiero, Isabel Rodriguez, Isaac Ssewanyana, Rebecca A. Dabbs, Christine M. Bachman, Bryan Greenhouse, Chris Drakeley, Phil L. Felgner, Will Stone, et al.

    The evaluation of protein antigens as putative serologic biomarkers of infection has increasingly shifted to high-throughput, multiplex approaches such as the protein microarray. In vitro transcription/translation (IVTT) systems–a similarly high-throughput protein expression method–are already widely utilised in the production of protein microarrays, though purified recombinant proteins derived from more traditional whole cell based expression systems also play an important role in biomarker characterisation. Here we have performed a side-by-side comparison of antigen-matched protein targets from an IVTT and purified recombinant system, on the same protein microarray. The magnitude and range of antibody responses to purified recombinants was found to be greater than that of IVTT proteins, and responses between targets from different expression systems did not clearly correlate. However, responses between amino acid sequence-matched targets from each expression system were more closely correlated. Despite the lack of a clear correlation between antigen-matched targets produced in each expression system, our data indicate that protein microarrays produced using either method can be used confidently, in a context dependent manner, though care should be taken when comparing data derived from contrasting approaches.


  • Open Access

    A Novel Malaria Lateral Flow Assay for Detecting Plasmodium falciparum Lactose Dehydrogenase in Busia, Uganda

    by Christine M. Bachman, David M. Cate, Ben Grant, Stephen Burkot, Jerry Mulondo, Helen V. Hsieh, Martin Chamai, Bakar Odongo, Peter Olwoch, Mayimuna Nalubega, et al.

    Rapid diagnostic tests (RDTs) for Plasmodium falciparum commonly detect histidine-rich protein 2 (HRP-2), but HRP-2 deletions are increasingly recognized. We evaluated a prototype test detecting parasite lactate dehydrogenase (pLDH) and compared it to commercially available RDTs at a health facility in Uganda, using quantitative polymerase chain reaction as a gold standard. The prototype pLDH test had a high sensitivity for infections with at least 100 parasites/µL (98%), comparable to HRP-2, and greater than an existing pLDH RDT (89%). Specificity for the prototype test was 99.5%, which is greater than the HRP-2 tests (93–95%). Therefore, the prototype pLDH test may be an attractive alternative malaria diagnostic.


  • Open Access

    Clinical validation of an open-access SARS-COV-2 antigen detection lateral flow assay, compared to commercially available assays

    by Christine M. Bachman, Benjamin D. Grant, Caitlin E. Anderson, Luis F. Alonzo, Spencer Garing, Sam A. Byrnes, Rafael Rivera, Stephen Burkot, Alexey Ball, James W. Stafford, et al.

    Rapid tests for SARS-COV-2 infection are important tools for pandemic control, but current rapid tests are based on proprietary designs and reagents. We report clinical validation results of an open-access lateral flow assay (OA-LFA) design using commercially available materials and reagents, along with RT-qPCR and commercially available comparators (BinaxNOW® and Sofia®). Adult patients with suspected COVID-19 based on clinical signs and symptoms, and with symptoms ≤7 days duration, underwent anterior nares (AN) sampling for the OA-LFA, Sofia®, BinaxNOW ™, and RT-qPCR, along with nasopharyngeal (NP) RT-qPCR. Results indicate a positive predictive agreement with NP sampling as 69% (60% -78%) OA-LFA, 74% (64% - 82%) Sofia®, and 82% (73% - 88%) BinaxNOW™. The implication for these results is that we provide an open-access LFA design that meets the minimum WHO target product profile for a rapid test, that virtually any diagnostic manufacturer could produce.


  • Open Access

    Measures of self-efficacy and norms for low-fat milk consumption are reliable and related to beverage consumption among 5th graders at school lunch

    by Victoria J Thompson, Christine Bachman, Kathy Watson, Tom Baranowski, Karen W Cullen

    Objective: To determine the reliability and validity of scales measuring low-fat milk consumption self-efficacy and norms during school lunch among a cohort of 5th graders.Design: Two hundred and seventy-five students completed lunch food records and a psychosocial questionnaire measuring self-efficacy and norms for school lunch low-fat milk consumption during the fall and spring semesters of the 1998–1999 academic year. Test–retest reliability was assessed in participants who also completed the questionnaire in the spring semester (n = 262). Principal component analyses identified and confirmatory factor analyses confirmed latent variables. Bivariate correlations measured construct validity.Setting: Houston-area middle school.Subjects: Fifth graders (n = 275) from one middle school in southeast Texas.Results: Two scales measuring psychosocial influences of low-fat milk consumption were identified and proved reliable in this population: milk self-efficacy and milk norms. Milk self-efficacy and norms were positively correlated with milk consumption and negatively correlated with consumption of sweetened beverages.Conclusions: These questionnaires can be used in similar interventions to measure the impact of self-efficacy and norms for drinking low-fat milk during school lunch.