Huabo Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huabo Xu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Bingyin Xu
School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo, China
1 shared publication- Fan Yang
Power Science Research Institute of State Grid Hubei Electric Power Co., Wuhan 430048, China
1 shared publication - Hechong Chen
Electric Power Research Institute of State Grid Hubei Electric Power Co., Ltd., Wuhan 430077, China
1 shared publication - Heng Chen
College of Electrical and Electronic Engineering, Shandong University of Technology, Zibo 255000, China
1 shared publication - Huihui Song
Harbin Institute of Technology (Weihai)
1 shared publication Pengwei Wang
School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo, China
1 shared publication
Latest Publications
- 19 November 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (1) , 7
GPS-synchronized impedance angle variation-based anti-islanding protection for distributed generators
- 19 November 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (1) , 7
GPS-synchronized impedance angle variation-based anti-islanding protection for distributed generators
- Open Access
An Anti-Islanding Protection Method Based on Voltage-Synchronous Impedance Angle Measurements
Grid-tied distributed generators (DGs) need to be equipped with anti-islanding protection to avoid the impact of unplanned islanding, which would affect system stability, auto-reclosing, and personal safety. Among the active anti-islanding protections, impedance measurements based on signal injection have the advantages of a low non-detection zone (NDZ) and are less prone to maloperation during grid disturbances; however, there are problems with signal interference in multi-DG systems. Hence, the impedance angle measurement method with signals injected synchronously is proposed. In this method, each DG injects phase-coherent signals to detect islanding using zero-cross points of the voltage (ZCPV) to avoid the protection failures caused by signal interference. An islanding identification criterion based on the measured impedance angle is proposed by analyzing the impedance characteristics of grid connection and islanding, which avoids the influence of variation of the DG operation state on islanding detection. Finally, we present a signal injection strategy and performance analysis in combination with an existing DG control platform, avoiding additional hardware investment. RTDS-based simulation verification shows that the proposed method can 100% avoid DG maloperation due to voltage and frequency disturbances during grid-connected operation and exit operation within 2 s when islanding occurs.
Open AccessAn Anti-Islanding Protection Method Based on Voltage-Synchronous Impedance Angle Measurements
Grid-tied distributed generators (DGs) need to be equipped with anti-islanding protection to avoid the impact of unplanned islanding, which would affect system stability, auto-reclosing, and personal safety. Among the active anti-islanding protections, impedance measurements based on signal injection have the advantages of a low non-detection zone (NDZ) and are less prone to maloperation during grid disturbances; however, there are problems with signal interference in multi-DG systems. Hence, the impedance angle measurement method with signals injected synchronously is proposed. In this method, each DG injects phase-coherent signals to detect islanding using zero-cross points of the voltage (ZCPV) to avoid the protection failures caused by signal interference. An islanding identification criterion based on the measured impedance angle is proposed by analyzing the impedance characteristics of grid connection and islanding, which avoids the influence of variation of the DG operation state on islanding detection. Finally, we present a signal injection strategy and performance analysis in combination with an existing DG control platform, avoiding additional hardware investment. RTDS-based simulation verification shows that the proposed method can 100% avoid DG maloperation due to voltage and frequency disturbances during grid-connected operation and exit operation within 2 s when islanding occurs.
- Open Access
Central Bulge Ferrite Core for Efficient Wireless Power Transfer
To improve the efficiency of the wireless power transfer (WPT) system without increasing the system size, a central bulge ferrite core with a novel configuration is proposed. The mutual inductance between magnetic coupling structures is able to increase obviously, which is approved by eigenfunction expansion method. In this paper, the mathematical models of the planar core and the central bulge core are established, respectively, as two types of the mutual inductance are calculated in same condition. The structure parameters of the central bulge ferrite core are further optimized by Maxwell magnetic field simulation. Experiments are conducted to compare the WPT efficiency of two types of ferrite cores in improving the efficiency of WPT system, in which the influence of transmission distance, lateral misalignment, and load variation are taken into account. The results show that central bulge ferrite core has better performance in WPT efficiency than the planar one, even in the case of long power transfer distance and lateral misalignment.
Open AccessCentral Bulge Ferrite Core for Efficient Wireless Power Transfer
To improve the efficiency of the wireless power transfer (WPT) system without increasing the system size, a central bulge ferrite core with a novel configuration is proposed. The mutual inductance between magnetic coupling structures is able to increase obviously, which is approved by eigenfunction expansion method. In this paper, the mathematical models of the planar core and the central bulge core are established, respectively, as two types of the mutual inductance are calculated in same condition. The structure parameters of the central bulge ferrite core are further optimized by Maxwell magnetic field simulation. Experiments are conducted to compare the WPT efficiency of two types of ferrite cores in improving the efficiency of WPT system, in which the influence of transmission distance, lateral misalignment, and load variation are taken into account. The results show that central bulge ferrite core has better performance in WPT efficiency than the planar one, even in the case of long power transfer distance and lateral misalignment.