Bartosz Sekuła
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bartosz Sekuła has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Aleksander Aszkiełowicz
Department of Anesthesiology and Intensive Therapy, Faculty of Medicine, Medical University of Gdansk, Gdansk, Poland
1 shared publication - Jakub Kukliński
Department of Anaesthesiology and Intensive Therapy, University Clinical Center, 80-952 Gdansk, Poland
1 shared publication - Karol P. Steckiewicz
Department of Anesthesiology and Intensive Therapy, Faculty of Medicine, Medical University of Gdansk, 80-210 Gdansk, Poland
1 shared publication - Radosław Owczuk
Department of Anesthesiology and Intensive Therapy, Faculty of Medicine, Medical University of Gdansk, Gdansk, Poland
1 shared publication
Latest Publications
- Open Access
- 10 August 2021
- Published by Springer Nature in Perioperative Medicine
- Vol. 10 (1) , 1-6
The influence of fasting and carbohydrate-enriched drink administration on body water amount and distribution: a volunteer randomized study
Background: Fasting prior to anesthesia is considered aspiration prophylaxis. However, prolonged food and drink restrictions may increase the risk of other complications. The aim of this study was to assess whether a carbohydrate-enriched drink (Nutricia™ preOp®), recommended by the enhanced recovery after surgery (ERAS) protocol, can improve body hydration in fasting healthy individuals. Methods: Measurements were done with the bioelectric impedance analysis with a Fresenius body composition monitor. Body composition, total body water, water distribution, and hemodynamic parameters were measured at the beginning of the study and after 10 h and 12 h of fasting. Patients fasted for 10 h and then were divided into two groups: the control (n = 40) and the pre-op group (n = 41). The pre-op group received 400 mL of Nutricia™ preOp®, as suggested in the ERAS guidance. The two-tailed Student’s t test was used to compare two groups with normally distributed data and homogenous variances; if variances were heterogeneous, Welch’s test was used. The Mann-Whitney U test was used to compare two groups with non-normal data distribution. p < 0.05 was considered statistically significant. Results: We found no significant differences between the control and pre-op groups regarding body water distribution and body composition. We did not observe significant losses in the total body water after fasting. Also, blood pressure was not affected by fasting. Conclusion: We have proven that pre-op did not impact either body composition or body water. Trial registration: ClinicalTrials.gov, NCT04665349. Registered on 11 December 2020—retrospectively registered.
- 10 August 2021
- Published by Springer Nature in Perioperative Medicine
- Vol. 10 (1) , 1-6
Open AccessThe influence of fasting and carbohydrate-enriched drink administration on body water amount and distribution: a volunteer randomized study
Background: Fasting prior to anesthesia is considered aspiration prophylaxis. However, prolonged food and drink restrictions may increase the risk of other complications. The aim of this study was to assess whether a carbohydrate-enriched drink (Nutricia™ preOp®), recommended by the enhanced recovery after surgery (ERAS) protocol, can improve body hydration in fasting healthy individuals. Methods: Measurements were done with the bioelectric impedance analysis with a Fresenius body composition monitor. Body composition, total body water, water distribution, and hemodynamic parameters were measured at the beginning of the study and after 10 h and 12 h of fasting. Patients fasted for 10 h and then were divided into two groups: the control (n = 40) and the pre-op group (n = 41). The pre-op group received 400 mL of Nutricia™ preOp®, as suggested in the ERAS guidance. The two-tailed Student’s t test was used to compare two groups with normally distributed data and homogenous variances; if variances were heterogeneous, Welch’s test was used. The Mann-Whitney U test was used to compare two groups with non-normal data distribution. p < 0.05 was considered statistically significant. Results: We found no significant differences between the control and pre-op groups regarding body water distribution and body composition. We did not observe significant losses in the total body water after fasting. Also, blood pressure was not affected by fasting. Conclusion: We have proven that pre-op did not impact either body composition or body water. Trial registration: ClinicalTrials.gov, NCT04665349. Registered on 11 December 2020—retrospectively registered.