Melvin Nova Gunawanto Barus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Melvin Nova Gunawanto Barus has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Muara Panusunan Lubis
Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine, Universitas Sumatera Utara, Medan, Indonesia
2 shared publications Bugis Mardina Lubis
Department of Pediatric, Faculty of Medicine, Universitas Sumatera Utara, Medan, 20155 Indonesia; Division of Neonatology, Department of Pediatric, H. Adam Malik General Hospital, Medan, Sumatera Utara, 20136 Indonesia
1 shared publication- Deri Edianto
Department of Obstetrics and Gynecology, Faculty of Medicine, Universitas Sumatera Utara, Medan, Indonesia
1 shared publication Desy Handayani
Department of Obstetrics and Gynecology, Faculty of Medicine, Universitas Sumatera Utara, Medan, 20155 Indonesia
1 shared publication- Dudy Aldiansyah
Department of Obstetrics and Gynecology, Fetomaternal Division, Faculty of Medicine, Sumatera Utara University, H. Adam Malik General Hospital, Medan, North Sumatera, Indonesia
1 shared publication Edwin M. Asroel
Department of Obstetrics and Gynecology, Faculty of Medicine, Universitas Sumatera Utara, Medan, 20155 Indonesia; Fetal Therapy Unit, Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, H. Adam Malik General Hospital, Medan, Sumatera Utara, 20136 Indonesia
1 shared publication
Latest Publications
- 1 August 2022
- Published by Bentham Science Publishers Ltd. in Current Women s Health Reviews
- Vol. 18 (3) , 1
Sensitivity Level of Placenta Accreta Index (PAI) Score and Placenta Accreta Spectrum (PAS) Stage as Preoperative Diagnostic Tools for Placenta Accreta Spectrum Disorders (PASD) at Haji Adam Malik General Hospital Medan Indonesia
Background: The incidence of Placenta Accreta Spectrum Disorders (PASD) has increased by 10-fold in 50 years along with the number of cesarean sections. Ultrasound examination using Placenta Accreta Index (PAI) score and Placenta Accreta Spectrum (PAS) stage as a predictor of PASD has been used worldwide at the antenatal screening. The high diagnostic value of these tools will help the physician to diagnose PASD early and minimize the rate of maternal neonatal mortality and morbidity. Objectives: To evaluate the value of PAI score and PAS stage in diagnosing PASD. Methods: This study is a diagnostic test study using the medical records of mothers who gave birth at Haji Adam Malik General Hospital Medan Indonesia between September 2017 to September 2020, who were diagnosed preoperatively as placenta previa suspected PASD through ultrasound examination using PAI score or PAS stage. The results of these two diagnostic tests were compared to clinical diagnostic criteria of PASD from The International Federation of Obstetrics and Gynecology (FIGO) with or without histopathological confirmation. Results: Of the 177 placenta previa cases, there were 142 women with PASD (80.2%). The diagnostic values of PAI score with 4.6 as an optimal cut-off point were 75% sensitivity, 83% specificity, 94% positive predictive values (PPV), and 47% negative predictive values (NPV). The diagnostic values of the PAS stage were 90% sensitivity, 83%, specificity, 96% PPV, and 68% NPV. Conclusion: PAI score and PAS stage have a diagnostic value that looks equally good when used as a diagnostic tool for PASD.
- 1 August 2022
- Published by Bentham Science Publishers Ltd. in Current Women s Health Reviews
- Vol. 18 (3) , 1
Sensitivity Level of Placenta Accreta Index (PAI) Score and Placenta Accreta Spectrum (PAS) Stage as Preoperative Diagnostic Tools for Placenta Accreta Spectrum Disorders (PASD) at Haji Adam Malik General Hospital Medan Indonesia
Background: The incidence of Placenta Accreta Spectrum Disorders (PASD) has increased by 10-fold in 50 years along with the number of cesarean sections. Ultrasound examination using Placenta Accreta Index (PAI) score and Placenta Accreta Spectrum (PAS) stage as a predictor of PASD has been used worldwide at the antenatal screening. The high diagnostic value of these tools will help the physician to diagnose PASD early and minimize the rate of maternal neonatal mortality and morbidity. Objectives: To evaluate the value of PAI score and PAS stage in diagnosing PASD. Methods: This study is a diagnostic test study using the medical records of mothers who gave birth at Haji Adam Malik General Hospital Medan Indonesia between September 2017 to September 2020, who were diagnosed preoperatively as placenta previa suspected PASD through ultrasound examination using PAI score or PAS stage. The results of these two diagnostic tests were compared to clinical diagnostic criteria of PASD from The International Federation of Obstetrics and Gynecology (FIGO) with or without histopathological confirmation. Results: Of the 177 placenta previa cases, there were 142 women with PASD (80.2%). The diagnostic values of PAI score with 4.6 as an optimal cut-off point were 75% sensitivity, 83% specificity, 94% positive predictive values (PPV), and 47% negative predictive values (NPV). The diagnostic values of the PAS stage were 90% sensitivity, 83%, specificity, 96% PPV, and 68% NPV. Conclusion: PAI score and PAS stage have a diagnostic value that looks equally good when used as a diagnostic tool for PASD.
- Open Access
- 1 March 2022
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 93 (C) , 106893
Twin reversed arterial perfusion sequence managed by bipolar cord coagulation and amniopatch
Introduction and importance: Twin Reversed Arterial Perfusion (TRAP) Sequence is a rare condition that occurs in monochorionic twin pregnancies, resulting in the coexistence of a normal “pump” twin and an acardiac twin. Indonesia is implementing fetal therapy centers that are starting to treat fetal cases such as TRAP Sequence. Case presentation: An 18 years old pregnant woman with monochorionic diamniotic pregnancy was detected by ultrasonographic examination. A live fetus with normal fetal heart rate estimated fetal weight was 661 g, and consistent with 25 w gestational age. Additionally, an acardiac twin with polyhydramnios and EFW of 1829 g. Bipolar cord coagulation, amniopatch, and amnioinfusion were performed. The patient's condition was stable and managed closely. Clinical discussion: This is the first procedure reported in Indonesia for TRAP sequence case. It reduces cardiac strain on the pump twin and increases the chance of survival. Conclusion: The patient was diagnosed with TRAP Sequence and bipolar cord coagulation to interrupt blood supply to the non-viable twin, amniopatch with autologous platelet concentrate followed by cryoprecipitate amnioinfusion were reported for the first time in Indonesia. Highlights:
- 1 March 2022
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 93 (C) , 106893
Open AccessTwin reversed arterial perfusion sequence managed by bipolar cord coagulation and amniopatch
Introduction and importance: Twin Reversed Arterial Perfusion (TRAP) Sequence is a rare condition that occurs in monochorionic twin pregnancies, resulting in the coexistence of a normal “pump” twin and an acardiac twin. Indonesia is implementing fetal therapy centers that are starting to treat fetal cases such as TRAP Sequence. Case presentation: An 18 years old pregnant woman with monochorionic diamniotic pregnancy was detected by ultrasonographic examination. A live fetus with normal fetal heart rate estimated fetal weight was 661 g, and consistent with 25 w gestational age. Additionally, an acardiac twin with polyhydramnios and EFW of 1829 g. Bipolar cord coagulation, amniopatch, and amnioinfusion were performed. The patient's condition was stable and managed closely. Clinical discussion: This is the first procedure reported in Indonesia for TRAP sequence case. It reduces cardiac strain on the pump twin and increases the chance of survival. Conclusion: The patient was diagnosed with TRAP Sequence and bipolar cord coagulation to interrupt blood supply to the non-viable twin, amniopatch with autologous platelet concentrate followed by cryoprecipitate amnioinfusion were reported for the first time in Indonesia. Highlights: