Amey Kelkar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amey Kelkar has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Norihiro Nishida
Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Japan
7 shared publications - Sudharshan Tripathi
The University of Toledo
7 shared publications - Vijay Kumar Goel
Engineering Center for Orthopedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedic Surgery, University of Toledo, Toledo, OH, USA
6 shared publications - Yogesh Kumaran
Engineering Center for Orthopaedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedics, The University of Toledo, Toledo, OH, USA
6 shared publications - Muzammil Mumtaz
The University of Toledo
5 shared publications - Takashi Sakai
Department of Orthopaedic Surgery, Yamaguchi University Graduate School of Medicine, Ube, Japan
5 shared publications
Latest Publications
- 16 July 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 128, 106622
Does spinopelvic alignment affect fixation stability in pelvic ring fractures?: A finite element study
- 16 July 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 128, 106622
Does spinopelvic alignment affect fixation stability in pelvic ring fractures?: A finite element study
- Open Access
- 2 April 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (4) , 348
Pelvic Ring Fractures: A Biomechanical Comparison of Sacral and Lumbopelvic Fixation Techniques
Background Context: Pelvic ring fractures are becoming more common in the aging population and can prove to be fatal, having mortality rates between 10% and 16%. Stabilization of these fractures is challenging and often require immediate internal fixation. Therefore, it is necessary to have a biomechanical understanding of the different fixation techniques for pelvic ring fractures. Methods: A previously validated three-dimensional finite element model of the lumbar spine, pelvis, and femur was used for this study. A unilateral pelvic ring fracture was simulated by resecting the left side of the sacrum and pelvis. Five different fixation techniques were used to stabilize the fracture. A compressive follower load and pure moment was applied to compare different biomechanical parameters including range of motion (contralateral sacroiliac joint, L1-S1 segment, L5-S1 segment), and stresses (L5-S1 nucleus stresses, instrument stresses) between different fixation techniques. Results: Trans-iliac–trans-sacral screw fixation at S1 and S2 showed the highest stabilization for horizontal and vertical displacement at the sacral fracture site and reduction of contralateral sacroiliac joint for bending and flexion range of motion by 165% and 121%, respectively. DTSF (Double transiliac rod and screw fixation) model showed highest stabilization in horizontal displacement at the pubic rami fracture site, while the L5_PF_W_CC (L5-Ilium posterior screw fixation with cross connectors) and L5_PF_WO_CC (L5-Ilium posterior screw fixation without cross connectors) showed higher rod stresses, reduced L1-S1 (approximately 28%), and L5-S1 (approximately 90%) range of motion. Conclusions: Longer sacral screw fixations were superior in stabilizing sacral and contralateral sacroiliac joint range of motion. Lumbopelvic fixations displayed a higher degree of stabilization in the horizontal displacement compared to vertical displacement of pubic rami fracture, while also indicating the highest rod stresses. When determining the surgical approach for pelvic ring fractures, patient-specific factors should be accounted for to weigh the advantages and disadvantages for each technique.
- 2 April 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (4) , 348
Open AccessPelvic Ring Fractures: A Biomechanical Comparison of Sacral and Lumbopelvic Fixation Techniques
Background Context: Pelvic ring fractures are becoming more common in the aging population and can prove to be fatal, having mortality rates between 10% and 16%. Stabilization of these fractures is challenging and often require immediate internal fixation. Therefore, it is necessary to have a biomechanical understanding of the different fixation techniques for pelvic ring fractures. Methods: A previously validated three-dimensional finite element model of the lumbar spine, pelvis, and femur was used for this study. A unilateral pelvic ring fracture was simulated by resecting the left side of the sacrum and pelvis. Five different fixation techniques were used to stabilize the fracture. A compressive follower load and pure moment was applied to compare different biomechanical parameters including range of motion (contralateral sacroiliac joint, L1-S1 segment, L5-S1 segment), and stresses (L5-S1 nucleus stresses, instrument stresses) between different fixation techniques. Results: Trans-iliac–trans-sacral screw fixation at S1 and S2 showed the highest stabilization for horizontal and vertical displacement at the sacral fracture site and reduction of contralateral sacroiliac joint for bending and flexion range of motion by 165% and 121%, respectively. DTSF (Double transiliac rod and screw fixation) model showed highest stabilization in horizontal displacement at the pubic rami fracture site, while the L5_PF_W_CC (L5-Ilium posterior screw fixation with cross connectors) and L5_PF_WO_CC (L5-Ilium posterior screw fixation without cross connectors) showed higher rod stresses, reduced L1-S1 (approximately 28%), and L5-S1 (approximately 90%) range of motion. Conclusions: Longer sacral screw fixations were superior in stabilizing sacral and contralateral sacroiliac joint range of motion. Lumbopelvic fixations displayed a higher degree of stabilization in the horizontal displacement compared to vertical displacement of pubic rami fracture, while also indicating the highest rod stresses. When determining the surgical approach for pelvic ring fractures, patient-specific factors should be accounted for to weigh the advantages and disadvantages for each technique.
- Open Access
- 2 February 2024
- Published by MDPI AG in Preprints.org
Pelvic Ring Fractures: A Biomechanical Comparison of Sacral and Lumbopelvic Fixation Techniques
Background Context Pelvic ring fractures are becoming more common in the aging population and can prove to be fatal, having mortality rates between 10% and 16%. Stabilization of these fractures is challenging and often require immediate internal fixation. Therefore, it is necessary to have a biomechanical understanding of the different fixation techniques for pelvic ring fractures. Methods A previously validated three-dimensional finite element model of the lumbar spine, pelvis, and femur was used for this study. A unilateral pelvic ring fracture was simulated by resecting the left side of the sacrum and pelvis. Five different fixation techniques were used to stabilize the fracture. A compressive follower load and pure moment was applied to compare different biomechanical parameters including range of motion (contralateral sacroiliac joint, L1-S1 segment, L5-S1 segment), and stresses (L5-S1 nucleus stresses, instrument stresses) between different fixation techniques. Results Transiliac -trans sacral screw fixation at S1 and S2 showed the highest stabilization for horizontal and vertical displacement at the sacral fracture site and reduction of contralateral sacroiliac joint for bending and flexion range of motion by 165% and 121%, respectively. DTSF (Double transiliac rod and screw fixation) model showed highest stabilization in horizontal displacement at the pubic rami fracture site, while the L5_PF_W_CC (L5-Ilium posterior screw fixation with cross connectors) and L5_PF_WO_CC ( L5-Ilium posterior screw fixation without cross connectors) showed higher rod stresses, reduced L1-S1 (approximately 28%), and L5-S1 (approximately 90%) range of motion. Conclusions Longer sacral screw fixations were superior in stabilizing sacral and contralateral sacroiliac joint range of motion. Lumbopelvic fixations displayed a higher degree of stabilization in the horizontal displacement compared to vertical displacement of pubic rami fracture, while also indicating the highest rod stresses. When determining the surgical approach for pelvic ring fractures, patient-specific factors should be accounted for to weigh the advantages and disadvantages for each technique.
- 2 February 2024
- Published by MDPI AG in Preprints.org
Open AccessPelvic Ring Fractures: A Biomechanical Comparison of Sacral and Lumbopelvic Fixation Techniques
Background Context Pelvic ring fractures are becoming more common in the aging population and can prove to be fatal, having mortality rates between 10% and 16%. Stabilization of these fractures is challenging and often require immediate internal fixation. Therefore, it is necessary to have a biomechanical understanding of the different fixation techniques for pelvic ring fractures. Methods A previously validated three-dimensional finite element model of the lumbar spine, pelvis, and femur was used for this study. A unilateral pelvic ring fracture was simulated by resecting the left side of the sacrum and pelvis. Five different fixation techniques were used to stabilize the fracture. A compressive follower load and pure moment was applied to compare different biomechanical parameters including range of motion (contralateral sacroiliac joint, L1-S1 segment, L5-S1 segment), and stresses (L5-S1 nucleus stresses, instrument stresses) between different fixation techniques. Results Transiliac -trans sacral screw fixation at S1 and S2 showed the highest stabilization for horizontal and vertical displacement at the sacral fracture site and reduction of contralateral sacroiliac joint for bending and flexion range of motion by 165% and 121%, respectively. DTSF (Double transiliac rod and screw fixation) model showed highest stabilization in horizontal displacement at the pubic rami fracture site, while the L5_PF_W_CC (L5-Ilium posterior screw fixation with cross connectors) and L5_PF_WO_CC ( L5-Ilium posterior screw fixation without cross connectors) showed higher rod stresses, reduced L1-S1 (approximately 28%), and L5-S1 (approximately 90%) range of motion. Conclusions Longer sacral screw fixations were superior in stabilizing sacral and contralateral sacroiliac joint range of motion. Lumbopelvic fixations displayed a higher degree of stabilization in the horizontal displacement compared to vertical displacement of pubic rami fracture, while also indicating the highest rod stresses. When determining the surgical approach for pelvic ring fractures, patient-specific factors should be accounted for to weigh the advantages and disadvantages for each technique.
- Open Access
- 9 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 9089
Laminoplasty on Kyphotic Cervical Alignments Suggests Poor Surgical Outcomes: A Comparative Finite Element Analysis of Laminoplasty on Different Alignments
Cervical laminoplasty is a useful for treatment for cervical myelopathy. However, this procedure has limitations for kyphotic cervical alignments. We used the finite element (FE) analysis and investigated the biomechanical changes in intact and laminoplasty models with lordosis, straight, and kyphosis cervical alignments. A three-dimensional FE model of the cervical spine (C2–C7) with ligaments was created from computer tomography. The model was modified with the following cobb angles (a) intact–lordotic model (intact–L; C2–C7 angle: −10°), (b) intact–straight model (intact–S; C2–C7 angle: 0°), and (c) intact–kyphotic model (intact–K; C2–C7 angle: 10°). The C3–C6 laminoplasty was conducted on the three intact models, represented by the laminoplasty–lordosis model (LM–L), laminoplasty–straight model (LM–S), and laminoplasty–kyphosis model (LM–K), respectively. Pure moment with compressive follower load of 100 N to represent the weight of the head/cranium and cervical muscle stabilization was applied to these models and the range of motion (ROM), annular stress, nucleus stress and facet forces were analyzed. ROM of intact–K and LM–K increased when compared to the other models. The LM–K had the highest mobility with 324% increase in ROM observed under extension, compared to LM–L. In addition, the annular stresses and nucleus stresses in intact–K and LM–K were higher compared to the other models. The maximum increase in annular stresses was about 309% in LM–K compared to the LM–L, observed at the C3–C4 segment. However, the facet contact forces were lower in the intact–K and LM–K, compared to the other models. Cases with cervical kyphosis alignment are at a disadvantage compared to cases with lordosis or straight alignment and should be treated with caution.
- 9 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 9089
Open AccessLaminoplasty on Kyphotic Cervical Alignments Suggests Poor Surgical Outcomes: A Comparative Finite Element Analysis of Laminoplasty on Different Alignments
Cervical laminoplasty is a useful for treatment for cervical myelopathy. However, this procedure has limitations for kyphotic cervical alignments. We used the finite element (FE) analysis and investigated the biomechanical changes in intact and laminoplasty models with lordosis, straight, and kyphosis cervical alignments. A three-dimensional FE model of the cervical spine (C2–C7) with ligaments was created from computer tomography. The model was modified with the following cobb angles (a) intact–lordotic model (intact–L; C2–C7 angle: −10°), (b) intact–straight model (intact–S; C2–C7 angle: 0°), and (c) intact–kyphotic model (intact–K; C2–C7 angle: 10°). The C3–C6 laminoplasty was conducted on the three intact models, represented by the laminoplasty–lordosis model (LM–L), laminoplasty–straight model (LM–S), and laminoplasty–kyphosis model (LM–K), respectively. Pure moment with compressive follower load of 100 N to represent the weight of the head/cranium and cervical muscle stabilization was applied to these models and the range of motion (ROM), annular stress, nucleus stress and facet forces were analyzed. ROM of intact–K and LM–K increased when compared to the other models. The LM–K had the highest mobility with 324% increase in ROM observed under extension, compared to LM–L. In addition, the annular stresses and nucleus stresses in intact–K and LM–K were higher compared to the other models. The maximum increase in annular stresses was about 309% in LM–K compared to the LM–L, observed at the C3–C4 segment. However, the facet contact forces were lower in the intact–K and LM–K, compared to the other models. Cases with cervical kyphosis alignment are at a disadvantage compared to cases with lordosis or straight alignment and should be treated with caution.
- 20 June 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (9) , 1531-1541
Biomechanical analysis of laminectomy, laminoplasty, posterior decompression with instrumented fusion, and anterior decompression with fusion for the kyphotic cervical spine
Purpose Anterior and posterior decompressions for cervical myelopathy and radiculopathy may lead to clinical improvements. However, patients with kyphotic cervical alignment have sometimes shown poor clinical outcomes with posterior decompression. There is a lack on report of mechanical analysis of the decompression procedures for kyphotic cervical alignment. Methods This study employed a three-dimensional finite element (FE) model of the cervical spine (C2-C7) with the pre-operative kyphotic alignment (Pre-OK) model and compared the biomechanical parameters (range of motion (ROM), annular stresses, nucleus stresses, and facet contact forces) for four decompression procedures at two levels (C3-C5); laminectomy (LN), laminoplasty (LP), posterior decompression with fusion (PDF), and anterior decompression with fusion (ADF). Pure moment with compressive follower load was applied to these models. Results PDF and ADF models’ global ROM were 40% at C2-C7 less than the Pre-OK, LN, and LP models. The annular and nucleus stresses decreased more than 10% at the surgery levels for ADF, and PDF, compared to the Pre-OK, LN, and LP models. However, the annular stresses at the adjacent cranial level (C2-C3) of ADF were 20% higher. The nucleus stresses of the caudal adjacent level (C5-C6) of PDF were 20% higher, compared to other models. The PDF and ADF models showed a less than 70% decrease in the facet forces at the surgery levels, compared to the Pre-OK, LN, and LP models. Conclusion The study concluded that posterior decompression, such as LN or LP, increases ROM, disc stress, and facet force and thus can lead to instability. Although there is the risk of adjacent segment disease (ASD), PDF and ADF can stabilize the cervical spine even for kyphotic alignments.
- 20 June 2022
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 17 (9) , 1531-1541
Biomechanical analysis of laminectomy, laminoplasty, posterior decompression with instrumented fusion, and anterior decompression with fusion for the kyphotic cervical spine
Purpose Anterior and posterior decompressions for cervical myelopathy and radiculopathy may lead to clinical improvements. However, patients with kyphotic cervical alignment have sometimes shown poor clinical outcomes with posterior decompression. There is a lack on report of mechanical analysis of the decompression procedures for kyphotic cervical alignment. Methods This study employed a three-dimensional finite element (FE) model of the cervical spine (C2-C7) with the pre-operative kyphotic alignment (Pre-OK) model and compared the biomechanical parameters (range of motion (ROM), annular stresses, nucleus stresses, and facet contact forces) for four decompression procedures at two levels (C3-C5); laminectomy (LN), laminoplasty (LP), posterior decompression with fusion (PDF), and anterior decompression with fusion (ADF). Pure moment with compressive follower load was applied to these models. Results PDF and ADF models’ global ROM were 40% at C2-C7 less than the Pre-OK, LN, and LP models. The annular and nucleus stresses decreased more than 10% at the surgery levels for ADF, and PDF, compared to the Pre-OK, LN, and LP models. However, the annular stresses at the adjacent cranial level (C2-C3) of ADF were 20% higher. The nucleus stresses of the caudal adjacent level (C5-C6) of PDF were 20% higher, compared to other models. The PDF and ADF models showed a less than 70% decrease in the facet forces at the surgery levels, compared to the Pre-OK, LN, and LP models. Conclusion The study concluded that posterior decompression, such as LN or LP, increases ROM, disc stress, and facet force and thus can lead to instability. Although there is the risk of adjacent segment disease (ASD), PDF and ADF can stabilize the cervical spine even for kyphotic alignments.
- Open Access
- 31 March 2022
- Published by MDPI AG in Preprints.org
Comparison of Laminoplasty on Lordotic, Straight and Kyphotic Cervical Alignments Suggest Poor Outcomes for Kyphotic Cervical Alignment: Finite Element Analysis
Background: Cervical laminoplasty is a useful for treatment of cervical myelopathy. However, this procedure has limitations for kyphotic cervical alignments. We used the finite element (FE) analysis and investigated the biomechanical changes in an intact and laminoplasty models with lordosis, straight, and kyphosis cervical alignments. Methods: A three-dimensional FE model of the cervical spine (C2-C7) with ligaments was created from computed tomography. The model was modified with the following cobb angles and the C3-C6 laminoplasty was conducted; a) laminoplasty-lordotic model (LM-L; C2-C7 angle: -10°), b) laminoplasty-straight model (LM-S; C2-C7 angle: 0°), and c) laminoplasty-kyphotic model (LM-K; C2-C7 angle: 10°). A pure moment with a compressive follower load of 100N to represent the weight of the head/cranium and cervical muscle stabilization was applied to these models. The range of motion (ROM), annular stress, nucleus stress and facet forces were analyzed. Results: ROM of LM-K increased when compared to the other models except for flexion. The LM-K had the highest mobility with 49% increase in ROM observed under extension, compared to the intact model. In all motion except for flexion, LM-L models’ ROM decreased by more than 10%, and LM-S and LM-K models’ ROM increased by more than 10% at C2-C7 compared to the intact model. The annular stresses and nucleus stresses in LM-K were higher compared to the other models. The maximum increase in annular stresses was about 194% in LM-K compared to the intact model, observed at the C3-C4 segment. The facet contact forces were lowest in the LM-K, compared to the other models.Conclusions: Patients with a cervical kyphosis alignment are at a disadvantage of increased kyphosis compared to cases with lordosis or straight alignment and should be treated with caution.
- 31 March 2022
- Published by MDPI AG in Preprints.org
Open AccessComparison of Laminoplasty on Lordotic, Straight and Kyphotic Cervical Alignments Suggest Poor Outcomes for Kyphotic Cervical Alignment: Finite Element Analysis
Background: Cervical laminoplasty is a useful for treatment of cervical myelopathy. However, this procedure has limitations for kyphotic cervical alignments. We used the finite element (FE) analysis and investigated the biomechanical changes in an intact and laminoplasty models with lordosis, straight, and kyphosis cervical alignments. Methods: A three-dimensional FE model of the cervical spine (C2-C7) with ligaments was created from computed tomography. The model was modified with the following cobb angles and the C3-C6 laminoplasty was conducted; a) laminoplasty-lordotic model (LM-L; C2-C7 angle: -10°), b) laminoplasty-straight model (LM-S; C2-C7 angle: 0°), and c) laminoplasty-kyphotic model (LM-K; C2-C7 angle: 10°). A pure moment with a compressive follower load of 100N to represent the weight of the head/cranium and cervical muscle stabilization was applied to these models. The range of motion (ROM), annular stress, nucleus stress and facet forces were analyzed. Results: ROM of LM-K increased when compared to the other models except for flexion. The LM-K had the highest mobility with 49% increase in ROM observed under extension, compared to the intact model. In all motion except for flexion, LM-L models’ ROM decreased by more than 10%, and LM-S and LM-K models’ ROM increased by more than 10% at C2-C7 compared to the intact model. The annular stresses and nucleus stresses in LM-K were higher compared to the other models. The maximum increase in annular stresses was about 194% in LM-K compared to the intact model, observed at the C3-C4 segment. The facet contact forces were lowest in the LM-K, compared to the other models.Conclusions: Patients with a cervical kyphosis alignment are at a disadvantage of increased kyphosis compared to cases with lordosis or straight alignment and should be treated with caution.
- Open Access
- 20 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (16) , 7645
Biomechanical Analysis of Posterior Ligaments of Cervical Spine and Laminoplasty
Cervical laminoplasty is a valuable procedure for myelopathy but it is associated with complications such as increased kyphosis. The effect of ligament damage during cervical laminoplasty on biomechanics is not well understood. We developed the C2–C7 cervical spine finite element model and simulated C3–C6 double-door laminoplasty. Three models were created (a) intact, (b) laminoplasty-pre (model assuming that the ligamentum flavum (LF) between C3–C6 was preserved during surgery), and (c) laminoplasty-res (model assuming that the LF between C3–C6 was resected during surgery). The models were subjected to physiological loading, and the range of motion (ROM), intervertebral nucleus stress, and facet contact forces were analyzed under flexion/extension, lateral bending, and axial rotation. The maximum change in ROM was observed under flexion motion. Under flexion, ROM in the laminoplasty-pre model increased by 100.2%, 111.8%, and 98.6% compared to the intact model at C3–C4, C4–C5, and C5–C6, respectively. The ROM in laminoplasty-res further increased by 105.2%, 116.8%, and 101.8% compared to the intact model at C3–C4, C4–C5, and C5–C6, respectively. The maximum stress in the annulus/nucleus was observed under left bending at the C4–C5 segment where an increase of 139.5% and 229.6% compared to the intact model was observed for laminoplasty-pre and laminoplasty-res model, respectively. The highest facet contact forces were observed at C4–C5 under axial rotation, where an increase of 500.7% and 500.7% was observed compared to the intact model for laminoplasty-pre and laminoplasty-res, respectively. The posterior ligaments of the cervical spine play a vital role in restoring/stabilizing the cervical spine. When laminoplasty is performed, the surgeon needs to be careful not to injure the posterior soft tissue, including ligaments such as LF.
- 20 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (16) , 7645
Open AccessBiomechanical Analysis of Posterior Ligaments of Cervical Spine and Laminoplasty
Cervical laminoplasty is a valuable procedure for myelopathy but it is associated with complications such as increased kyphosis. The effect of ligament damage during cervical laminoplasty on biomechanics is not well understood. We developed the C2–C7 cervical spine finite element model and simulated C3–C6 double-door laminoplasty. Three models were created (a) intact, (b) laminoplasty-pre (model assuming that the ligamentum flavum (LF) between C3–C6 was preserved during surgery), and (c) laminoplasty-res (model assuming that the LF between C3–C6 was resected during surgery). The models were subjected to physiological loading, and the range of motion (ROM), intervertebral nucleus stress, and facet contact forces were analyzed under flexion/extension, lateral bending, and axial rotation. The maximum change in ROM was observed under flexion motion. Under flexion, ROM in the laminoplasty-pre model increased by 100.2%, 111.8%, and 98.6% compared to the intact model at C3–C4, C4–C5, and C5–C6, respectively. The ROM in laminoplasty-res further increased by 105.2%, 116.8%, and 101.8% compared to the intact model at C3–C4, C4–C5, and C5–C6, respectively. The maximum stress in the annulus/nucleus was observed under left bending at the C4–C5 segment where an increase of 139.5% and 229.6% compared to the intact model was observed for laminoplasty-pre and laminoplasty-res model, respectively. The highest facet contact forces were observed at C4–C5 under axial rotation, where an increase of 500.7% and 500.7% was observed compared to the intact model for laminoplasty-pre and laminoplasty-res, respectively. The posterior ligaments of the cervical spine play a vital role in restoring/stabilizing the cervical spine. When laminoplasty is performed, the surgeon needs to be careful not to injure the posterior soft tissue, including ligaments such as LF.