Ruijun Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ruijun Chen has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Yaw-Shyan Tsay
Department of Architecture, National Cheng Kung University, Tainan, Taiwan
7 shared publications - Yukai Zou
School of Architecture and Urban Planning, Guangzhou University, Guangzhou 510006, China
2 shared publications - Chao Ren
The University of Hong Kong
1 shared publication Chen-Chi Fan
1 shared publicationCuiping Liao
1 shared publication- Gaofeng Deng
State Key Laboratory of Building Safety and Environment, China Academy of Building Research, Beijing 100013, China
1 shared publication
Latest Publications
- 25 September 2026
- Published by Elsevier in Building and Environment
- Vol. 306
Assessing urban heat vulnerability in China's ten furnace cities through social sensing: Linking exposure, responses, and built environment
- 25 September 2026
- Published by Elsevier in Building and Environment
- Vol. 306
Assessing urban heat vulnerability in China's ten furnace cities through social sensing: Linking exposure, responses, and built environment
- Top Cited Papers
- 2 May 2026
- Published by Elsevier in Sustainable Cities and Society
- Vol. 145
Urban heat on the move: How functional zoning and shifting populations intensify day–night exposure hotspots
- 2 May 2026
- Published by Elsevier in Sustainable Cities and Society
- Vol. 145
Top Cited PapersUrban heat on the move: How functional zoning and shifting populations intensify day–night exposure hotspots
- 13 September 2025
- Published by Elsevier in Energy Policy
- Vol. 208
Integrating carbon emissions and sinks for a just transition: A spatial framework for the Guangdong-Hong Kong-Macao Greater Bay Area
- 13 September 2025
- Published by Elsevier in Energy Policy
- Vol. 208
Integrating carbon emissions and sinks for a just transition: A spatial framework for the Guangdong-Hong Kong-Macao Greater Bay Area
- Open Access
Responsibility Management through Responsibility Networks
The safety management is critically important in the workplace. Unfortunately, responsibility issues therein such as inefficient supervision, poor evaluation and inadequate perception have not been properly addressed. To this end, in this paper, we deploy the Internet of Responsibilities (IoR) for responsibility management. Through the building of IoR framework, hierarchical responsibility management, automated responsibility evaluation at all level and efficient responsibility perception are achieved. The practical deployment of IoR system showed its effective responsibility management capability in various workplaces.
Open AccessResponsibility Management through Responsibility Networks
The safety management is critically important in the workplace. Unfortunately, responsibility issues therein such as inefficient supervision, poor evaluation and inadequate perception have not been properly addressed. To this end, in this paper, we deploy the Internet of Responsibilities (IoR) for responsibility management. Through the building of IoR framework, hierarchical responsibility management, automated responsibility evaluation at all level and efficient responsibility perception are achieved. The practical deployment of IoR system showed its effective responsibility management capability in various workplaces.
- Open Access
An Air Conditioning Design Strategy of the Stepped Hall Based on Building Performance Simulation
This study proposed an improved air conditioning design strategy based on building performance simulation for a stepped hall. The air velocity and air change rate of the case were measured on-site, which were compared with the simulation data to verify the reliability of the building simulation model. Then, the fully mixing ventilation scheme and the design schemes proposed in this study were simulated. Finally, the building simulation results were summarized to confirm the applicability of the air conditioning design strategy. The building performance results showed that the air distribution performance index (ADPI) value was 76.95% in the original case. Nevertheless, the effective draft temperature (EDT) in the middle seat area exceeded the standard value, indicating that a local cold shock would occur. Moreover, its scale for ventilation efficiency (SVE6) in the residential area was 2.54. However, the SVE6s in the other schemes were between 0.89 and 0.92. It means that the proposed schemes only needed to take one-third of the time to exhaust air. These three indicators’ visualization results can analyze the advantages and disadvantages of each scheme. Therefore, the improved building performance simulation strategy could inspect the design effect and give suggestions quickly for air conditioning design.
Open AccessAn Air Conditioning Design Strategy of the Stepped Hall Based on Building Performance Simulation
This study proposed an improved air conditioning design strategy based on building performance simulation for a stepped hall. The air velocity and air change rate of the case were measured on-site, which were compared with the simulation data to verify the reliability of the building simulation model. Then, the fully mixing ventilation scheme and the design schemes proposed in this study were simulated. Finally, the building simulation results were summarized to confirm the applicability of the air conditioning design strategy. The building performance results showed that the air distribution performance index (ADPI) value was 76.95% in the original case. Nevertheless, the effective draft temperature (EDT) in the middle seat area exceeded the standard value, indicating that a local cold shock would occur. Moreover, its scale for ventilation efficiency (SVE6) in the residential area was 2.54. However, the SVE6s in the other schemes were between 0.89 and 0.92. It means that the proposed schemes only needed to take one-third of the time to exhaust air. These three indicators’ visualization results can analyze the advantages and disadvantages of each scheme. Therefore, the improved building performance simulation strategy could inspect the design effect and give suggestions quickly for air conditioning design.
- Open Access
- 28 June 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 8093-8107
Carbon emission and thermal comfort prediction model for an office building considering the contribution rate of design parameters
- 28 June 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 8093-8107
Open AccessCarbon emission and thermal comfort prediction model for an office building considering the contribution rate of design parameters
- Open Access
Effect of Color Temperature and Illuminance on Psychology, Physiology, and Productivity: An Experimental Study
In this study, we investigated the impact of the lighting environment on psychological perception, physiology, and productivity and then designed lighting control strategies based on the experimental results. The research was conducted in a smart lighting laboratory, and 67 subjects were tested in different illuminances and correlated color temperatures (CCTs). During the experiment, the physiological data of subjects were continuously recorded, while the psychology and productivity results were evaluated by questionnaires and working tests, respectively. The experimental results found that both illuminance and CCT could significantly influence the feeling of comfort and relaxation of the subjects. Warm CCT and higher illuminance (3000 K–590 lux) made subjects feel more comfortable. Productivity reached its maximum value with illuminance above 500 lux and equivalent melanopic lux (EML) higher than 150. The brain-wave and heart-rate changes did not have a close relationship with either illuminance or CCT, but the heart rate slightly increased in the adjustable lighting mode. Regardless of the initial value setting, the subjects preferred intermediate CCT (4200 K) and bright illumination (500 lux) after self-adjustment. Finally, we proposed three comprehensive lighting control strategies based on psychology, productivity, circadian rhythm, and energy-saving.
Open AccessEffect of Color Temperature and Illuminance on Psychology, Physiology, and Productivity: An Experimental Study
In this study, we investigated the impact of the lighting environment on psychological perception, physiology, and productivity and then designed lighting control strategies based on the experimental results. The research was conducted in a smart lighting laboratory, and 67 subjects were tested in different illuminances and correlated color temperatures (CCTs). During the experiment, the physiological data of subjects were continuously recorded, while the psychology and productivity results were evaluated by questionnaires and working tests, respectively. The experimental results found that both illuminance and CCT could significantly influence the feeling of comfort and relaxation of the subjects. Warm CCT and higher illuminance (3000 K–590 lux) made subjects feel more comfortable. Productivity reached its maximum value with illuminance above 500 lux and equivalent melanopic lux (EML) higher than 150. The brain-wave and heart-rate changes did not have a close relationship with either illuminance or CCT, but the heart rate slightly increased in the adjustable lighting mode. Regardless of the initial value setting, the subjects preferred intermediate CCT (4200 K) and bright illumination (500 lux) after self-adjustment. Finally, we proposed three comprehensive lighting control strategies based on psychology, productivity, circadian rhythm, and energy-saving.