YTYuya Taguchi

Yuya Taguchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuya Taguchi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cut-off value of mal-apposition volume and depth for resolution at early phase of acute incomplete stent apposition after CoCr-EES implantation

    by Yohei Uchimura, Tomonori Itoh, Hideto Oda, Yuya Taguchi, Wataru Sasaki, Kyosuke Kaneko, Tsubasa Sakamoto, Iwao Goto, Masafumi Sakuma, Masaru Ishida, et al.

    The purpose of this study was to clarify a cut-off value for acute incomplete stent apposition (ISA) volume and maximum-depth to predict ISA resolution at 1- and 3-month follow-up in patients treated with cobalt–chromium everolimus-eluting stents. In total, 95 cases and 103 stents were registered in the MECHANISM-Elective sub-study. Acute ISA-volume was measured by the trapezoid rule. ISA resolution of cut-off value at 1- and 3-month was estimated by ISA-volume and maximum-depth using receiver operatorating characteristic curve analysis. The total number of analysed acute ISAs was 202 in the 1-month group and 225 in the 3-month group. A total of 123 ISAs at 1-month and a total of 169 ISAs at 3-month had been resolved. The cut-off value of ISA resolution by ISA-volume was 0.169 mm3 at 1-month (AUC: 0.725, sensitivity: 72.2%, specificity: 61.0%) and 0.295 mm3 at 3-month (AUC: 0.757, sensitivity: 75.0%, specificity: 60.4%). The cut-off value of ISA resolution by ISA maximum-depth demonstrated was 0.285 mm at 1-month (area under curve (AUC): 0.789, sensitivity: 70.9%, specificity: 69.9%) and 0.305 mm at 3-month (AUC: 0.663, sensitivity: 60.7%, specificity: 66.9%). Incidence of ISA resolution was significantly lower in combination with cut-off values of ISA-volume and maximum-depth (33%, p < 0.001, at 1-month; 56%, p = 0.003, at 3-month). Combining the cut-off value of ISA-volume with the maximum-depth might be helpful to consider the endpoint of the PCI procedure.


  • Coronary risk factors associated with OCT macrophage images and their response after CoCr everolimus-eluting stent implantation in patients with stable coronary artery disease

    by Yuya Taguchi, Tomonori Itoh, Hideto Oda, Yohei Uchimura, Kyosuke Kaneko, Tsubasa Sakamoto, Iwao Goto, Masafumi Sakuma, Masaru Ishida, Daisuke Terashita, et al.


  • Anomalous inferior mesenteric artery supplying the ascending, transverse, descending, and sigmoid colons

    by Tamami Abe, Ayako Ujiie, Yuya Taguchi, Shun Satoh, Takahiro Shibuya, Yan Jun, Sumio Isogai, Yoh-Ichi Satoh

    We have encountered in our anatomical practice the first case and an extremely rare second case in which the ascending, transverse, descending, and sigmoid colons were supplied by the inferior mesenteric artery. The causes of colic artery anomalies are generally explained in conjunction with the development of the superior mesenteric artery, which is intimately related to embryonic elongation and midgut rotation. However, this embryological model was inapplicable to both cases. This difficulty motivated us to seek possible relationships with reported anomalous inferior mesenteric arteries in adults as well as their embryological causes. We consider that the aberrant right colic artery found in 2009 is an “intermesenteric artery” which anastomoses the superior (or its middle colic branch) and inferior mesenteric artery, but secondarily lost its origin from the superior mesenteric artery. The aberrant colic artery found in 2010 is a “middle–inferior mesenteric artery” in which the inferior mesenteric artery formed a common trunk with remnant middle mesenteric artery.