Belal Al-Qudsi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Belal Al-Qudsi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Frank Ellinger
Chair for Circuit Design and Network Theory, Technische Universität Dresden, Dresden, Germany
2 shared publicationsMohammed El-Shennawy
Chair for Circuit Design and Network Theory, Technische Universität Dresden, Dresden, Germany
2 shared publicationsNiko Joram
Chair for Circuit Design and Network Theory, Technische Universität Dresden, Dresden, Germany
2 shared publications- Frank Ellinger
Chair for Circuit Design and Network Theory, Technische Universität Dresden, 01069 Dresden, Germany
1 shared publication Marco Gunia
Chair for Circuit Design and Network Theory, Technische Universität Dresden, Dresden, Germany
1 shared publicationMohammed El‐Shennawy
Chair for Circuit Design and Network Theory Technische Universität Dresden 01062 Dresden Germany
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by Institution of Engineering and Technology (IET) in IET Signal Processing
- Vol. 2024 (1)
Critical Design Considerations on Continuous Frequency Modulation Localization Systems
Real‐time locating systems (RTLSs) suffer from clock synchronization inaccuracy among their distributed reference nodes. Conventional systems require periodic time synchronization and typically necessitate a two‐way ranging (TWR) clock synchronization protocol to eliminate their measurement errors. Particularly, frequency‐modulated continuous‐wave (FMCW) time‐based location systems pose unique design considerations on the TWR that have a significant impact on the quality of their measurements. In this paper, a valid operation design diagram is proposed for the case of an FMCW time‐based TWR synchronization protocol. The proposed diagram represents an intersection area of two boundary curves that indicate the functionality of the system at a given frequency bandwidth, spectral length, and clock synchronization ambiguity. It presents an intuitive illustration of the measurement’s expected accuracy by indicating a larger intersection area for relaxed design conditions and vice versa. Furthermore, the absence of a working condition can easily be detected before proceeding with the actual system development. To demonstrate the feasibility of the proposed diagram, four scenarios with different design constraints were evaluated in a Monte‐Carlo model of a basic TWR system. Moreover, an experimental measurement setup demonstrated the validity of the proposed diagram. Both the simulation and experimental outcomes show that the indicated valid conditions and the distribution of the measurements’ accuracy are in very good agreement.
- 1 January 2024
- Published by Institution of Engineering and Technology (IET) in IET Signal Processing
- Vol. 2024 (1)
Open AccessCritical Design Considerations on Continuous Frequency Modulation Localization Systems
Real‐time locating systems (RTLSs) suffer from clock synchronization inaccuracy among their distributed reference nodes. Conventional systems require periodic time synchronization and typically necessitate a two‐way ranging (TWR) clock synchronization protocol to eliminate their measurement errors. Particularly, frequency‐modulated continuous‐wave (FMCW) time‐based location systems pose unique design considerations on the TWR that have a significant impact on the quality of their measurements. In this paper, a valid operation design diagram is proposed for the case of an FMCW time‐based TWR synchronization protocol. The proposed diagram represents an intersection area of two boundary curves that indicate the functionality of the system at a given frequency bandwidth, spectral length, and clock synchronization ambiguity. It presents an intuitive illustration of the measurement’s expected accuracy by indicating a larger intersection area for relaxed design conditions and vice versa. Furthermore, the absence of a working condition can easily be detected before proceeding with the actual system development. To demonstrate the feasibility of the proposed diagram, four scenarios with different design constraints were evaluated in a Monte‐Carlo model of a basic TWR system. Moreover, an experimental measurement setup demonstrated the validity of the proposed diagram. Both the simulation and experimental outcomes show that the indicated valid conditions and the distribution of the measurements’ accuracy are in very good agreement.
- Open Access
- 1 January 2018
- Published by Institution of Engineering and Technology (IET) in IET Radar, Sonar & Navigation
- Vol. 12 (1) , 46-55
Scalable indoor positioning system with multi‐band FMCW
This study presents a multi‐band scalable positioning system that not only provides accurate means of navigation but also seamlessly extends the maximum number of reference and mobile nodes. Time synchronisation is carried out wirelessly, hence minimising the required hardware to easily set up the system. Due to its high precision and immunity to radio frequency interferences, a multi‐band frequency modulated continuous wave (FMCW) radar system is designed particularly to handle the core time measurements. Large parts of the radar front‐end are fully integrated in an application‐specific integrated circuit. Furthermore, in order to withstand the complex indoor conditions, the system engages a particle filter based tracking algorithm as a data fusion platform. The measurements were evaluated in several practical conditions and compared with the state‐of‐the‐art techniques. The evaluation scenarios include areas with line‐of‐sight and non‐line‐of‐sight conditions. A root mean square positioning error of 2 , in both outdoor and indoor conditions, respectively. To the best of the authors’ knowledge, the proposed system outperforms the current commercial systems not only in the aspect of positioning error, but also in the coverage efficiency.
- 1 January 2018
- Published by Institution of Engineering and Technology (IET) in IET Radar, Sonar & Navigation
- Vol. 12 (1) , 46-55
Open AccessScalable indoor positioning system with multi‐band FMCW
This study presents a multi‐band scalable positioning system that not only provides accurate means of navigation but also seamlessly extends the maximum number of reference and mobile nodes. Time synchronisation is carried out wirelessly, hence minimising the required hardware to easily set up the system. Due to its high precision and immunity to radio frequency interferences, a multi‐band frequency modulated continuous wave (FMCW) radar system is designed particularly to handle the core time measurements. Large parts of the radar front‐end are fully integrated in an application‐specific integrated circuit. Furthermore, in order to withstand the complex indoor conditions, the system engages a particle filter based tracking algorithm as a data fusion platform. The measurements were evaluated in several practical conditions and compared with the state‐of‐the‐art techniques. The evaluation scenarios include areas with line‐of‐sight and non‐line‐of‐sight conditions. A root mean square positioning error of 2 , in both outdoor and indoor conditions, respectively. To the best of the authors’ knowledge, the proposed system outperforms the current commercial systems not only in the aspect of positioning error, but also in the coverage efficiency.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A coverage efficient FMCW positioning system
Accurate positioning with a limited number of reference stations is challenging. Several commercial systems achieve good accuracy by increasing the system complexity. Simplifying the system and reducing the number of reference stations is highly desirable. This paper presents a coverage efficient highly integrated local positioning system. The system is optimized for minimum positioning error with maximum effective coverage area. It is highly integrated and relies on the traditional frequency modulated continuous wave (FMCW) radar to provide the position information. Starting from the hardware to the final positioning algorithm, the research provides an intensive insight into the system details. The proposed system was practically tested for reliability and accuracy. To mitigate the multipath propagation issue, the system switches between the 2.4 and 5.8 GHz industrial, scientific and medical (ISM) bands. An overall positioning precision of around 10 cm and accuracy of less than or equal to 0.39 m was achieved with a coverage area of around 48 and 24 m2 per reference station, in both outdoor and indoor conditions, respectively.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A coverage efficient FMCW positioning system
Accurate positioning with a limited number of reference stations is challenging. Several commercial systems achieve good accuracy by increasing the system complexity. Simplifying the system and reducing the number of reference stations is highly desirable. This paper presents a coverage efficient highly integrated local positioning system. The system is optimized for minimum positioning error with maximum effective coverage area. It is highly integrated and relies on the traditional frequency modulated continuous wave (FMCW) radar to provide the position information. Starting from the hardware to the final positioning algorithm, the research provides an intensive insight into the system details. The proposed system was practically tested for reliability and accuracy. To mitigate the multipath propagation issue, the system switches between the 2.4 and 5.8 GHz industrial, scientific and medical (ISM) bands. An overall positioning precision of around 10 cm and accuracy of less than or equal to 0.39 m was achieved with a coverage area of around 48 and 24 m2 per reference station, in both outdoor and indoor conditions, respectively.