Joost Th. M. de Wolf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Joost Th. M. de Wolf has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Johanna Cornelia Kluin-Nelemans
Department of Hematology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
4 shared publications Lotte Bosman
From the Department of Hematology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
2 shared publicationsAndre B. Mulder
1 shared publicationAndré B Mulder
Department of Laboratory Medicine, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
1 shared publicationL. Bosman
Department of Hematology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
1 shared publicationN. J. G. M. Veeger
Trial Coordination Center, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
1 shared publication
Latest Publications
- 14 July 2010
- Published by Wiley in Vox Sanguinis
- Vol. 99 (2) , 123-130
Transfused stored platelets have the same haemostatic function as circulating native platelets
As thrombelastography (TEG) measures haemostasis in whole blood, we used this instrument to study whether transfused platelets (PLTs) have the same haemostatic function compared to native circulating PLTs. Further, we studied the effect of storage time on the haemostatic potential of platelet concentrates (PCs). During the decrease in PLT count after chemotherapy, TEG parameters were measured serially until the transfusion trigger was reached in 92 patients. TEG parameters for different ranges of native circulating PLTs could be assessed, which were compared to ranges obtained in the thrombocytopenic period in which the patient received PLT transfusions. Finally, we compared the haemostatic potential of fresh PCs (1-3 days) with PCs with longer storage time (4-5 days). No differences could be found in haemostatic potential between native PLTs and transfused stored PLTs (all P-values > or = 0.1). The transfusion of fresh PLTs demonstrated better haemostatic effects than longer stored PLTs, measured 1 h after transfusion. Both the time until a fixed level of clot firmness was reached (K-time) and the rate of clot growth (alpha angle) were superior for fresh PCs. TEG is able to monitor the haemostatic effects of PLT transfusion, with comparable haemostatic properties of native circulating and transfused stored-PLTs. Further, our data suggest that limited storage time is associated with a better haemostatic capacity. However, before TEG can be applied as a qualitative test in PLT transfusion, further research is needed with focus on clinical outcomes like bleeding episodes.
- 14 July 2010
- Published by Wiley in Vox Sanguinis
- Vol. 99 (2) , 123-130
Transfused stored platelets have the same haemostatic function as circulating native platelets
As thrombelastography (TEG) measures haemostasis in whole blood, we used this instrument to study whether transfused platelets (PLTs) have the same haemostatic function compared to native circulating PLTs. Further, we studied the effect of storage time on the haemostatic potential of platelet concentrates (PCs). During the decrease in PLT count after chemotherapy, TEG parameters were measured serially until the transfusion trigger was reached in 92 patients. TEG parameters for different ranges of native circulating PLTs could be assessed, which were compared to ranges obtained in the thrombocytopenic period in which the patient received PLT transfusions. Finally, we compared the haemostatic potential of fresh PCs (1-3 days) with PCs with longer storage time (4-5 days). No differences could be found in haemostatic potential between native PLTs and transfused stored PLTs (all P-values > or = 0.1). The transfusion of fresh PLTs demonstrated better haemostatic effects than longer stored PLTs, measured 1 h after transfusion. Both the time until a fixed level of clot firmness was reached (K-time) and the rate of clot growth (alpha angle) were superior for fresh PCs. TEG is able to monitor the haemostatic effects of PLT transfusion, with comparable haemostatic properties of native circulating and transfused stored-PLTs. Further, our data suggest that limited storage time is associated with a better haemostatic capacity. However, before TEG can be applied as a qualitative test in PLT transfusion, further research is needed with focus on clinical outcomes like bleeding episodes.
- Open Access
- 1 July 2010
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 21 (5) , 389-397
Thrombocytopenia affects plasmatic coagulation as measured by thrombelastography
Thrombelastography (TEG) is used as a point-of-care test of hemostasis. Different components of the test tracing are considered to reflect various parts of the hemostatic system and to distinguish low platelet count, platelet dysfunction or both from lack of plasmatic coagulation factors. To analyze the influence of one single element of the coagulation system, namely the platelet count, we used TEG serially in patients with well documented transient thrombocytopenia. A total of 189 TEG analyses were performed from 16 patients with a hematological malignancy in remission, receiving consolidation courses of chemotherapy. TEG outcomes using unmanipulated and citrated blood samples at a median of 11 times (range 1–17) in the same patients during the decrease of platelet count in response to chemotherapy were compared with outcomes in 120 healthy adults from various age categories. We found a correlation (r = 0.7, P < 0.001) between TEG clot strength (maximum amplitude) and platelet count. Moreover, platelet count was correlated respectively with the initial rate of clot formation (reaction time and clotting time), the rate of clot growth (alpha angle), and also with maximum thrombus generation, time to maximum thrombus generation and total thrombus generation. We conclude that platelet count not only affects the strength of clot formation, as was expected, but also all other phases of plasmatic coagulation. Citration of the blood sample, aiming at easy storage of the material, masked some of the important biological parameters of coagulation.
- 1 July 2010
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 21 (5) , 389-397
Open AccessThrombocytopenia affects plasmatic coagulation as measured by thrombelastography
Thrombelastography (TEG) is used as a point-of-care test of hemostasis. Different components of the test tracing are considered to reflect various parts of the hemostatic system and to distinguish low platelet count, platelet dysfunction or both from lack of plasmatic coagulation factors. To analyze the influence of one single element of the coagulation system, namely the platelet count, we used TEG serially in patients with well documented transient thrombocytopenia. A total of 189 TEG analyses were performed from 16 patients with a hematological malignancy in remission, receiving consolidation courses of chemotherapy. TEG outcomes using unmanipulated and citrated blood samples at a median of 11 times (range 1–17) in the same patients during the decrease of platelet count in response to chemotherapy were compared with outcomes in 120 healthy adults from various age categories. We found a correlation (r = 0.7, P < 0.001) between TEG clot strength (maximum amplitude) and platelet count. Moreover, platelet count was correlated respectively with the initial rate of clot formation (reaction time and clotting time), the rate of clot growth (alpha angle), and also with maximum thrombus generation, time to maximum thrombus generation and total thrombus generation. We conclude that platelet count not only affects the strength of clot formation, as was expected, but also all other phases of plasmatic coagulation. Citration of the blood sample, aiming at easy storage of the material, masked some of the important biological parameters of coagulation.
- 1 July 2010
- Published by Wiley in Transfusion
- Vol. 50 (7) , 1536-1544
Effects of red blood cells on hemostasis
BACKGROUND: Currently there is no sensitive laboratory test to establish the influence of red blood cells (RBCs) on hemostasis. As thromboelastography (TEG) measures hemostasis in whole blood, taking into account the interactions of all cellular elements, we used this instrument to investigate the role that RBCs play in hemostasis.STUDY DESIGN AND METHODS: In 29 patients with chemotherapy‐induced anemia we studied the effect of progressive anemia on the coagulation profile. In 24 patients with chronic anemia we studied the effect of transfusion of RBCs on coagulation. Finally, in 18 patients we evaluated whether storage time of RBCs has additional effects on hemostasis.RESULTS: We observed a significant negative correlation between hemoglobin and TEG variables related to both clot strength and elasticity (p < 0.05). Moreover, anemia was associated with a delay in the initiation of the coagulation cascade. Correction of anemia by RBC transfusion resulted in significant shortening of this initiation phase with now the opposite effect on clot strength and elasticity. The negative effects on clot quality were significantly worse when fresh RBCs were transfused compared to longer‐stored RBCs. Furthermore, in contrast to the longer‐stored RBCs, fresh RBCs did not enhance initial fibrin formation.CONCLUSIONS: In this study we found that anemia was associated with a delay in the initiation of the coagulation cascade with a finally formed clot with superior strength and viscoelastic properties. Transfusion of RBCs was associated with impaired clot quality, with even worse effects on the initial fibrin build‐up and clot quality by fresh RBCs.
- 1 July 2010
- Published by Wiley in Transfusion
- Vol. 50 (7) , 1536-1544
Effects of red blood cells on hemostasis
BACKGROUND: Currently there is no sensitive laboratory test to establish the influence of red blood cells (RBCs) on hemostasis. As thromboelastography (TEG) measures hemostasis in whole blood, taking into account the interactions of all cellular elements, we used this instrument to investigate the role that RBCs play in hemostasis.STUDY DESIGN AND METHODS: In 29 patients with chemotherapy‐induced anemia we studied the effect of progressive anemia on the coagulation profile. In 24 patients with chronic anemia we studied the effect of transfusion of RBCs on coagulation. Finally, in 18 patients we evaluated whether storage time of RBCs has additional effects on hemostasis.RESULTS: We observed a significant negative correlation between hemoglobin and TEG variables related to both clot strength and elasticity (p < 0.05). Moreover, anemia was associated with a delay in the initiation of the coagulation cascade. Correction of anemia by RBC transfusion resulted in significant shortening of this initiation phase with now the opposite effect on clot strength and elasticity. The negative effects on clot quality were significantly worse when fresh RBCs were transfused compared to longer‐stored RBCs. Furthermore, in contrast to the longer‐stored RBCs, fresh RBCs did not enhance initial fibrin formation.CONCLUSIONS: In this study we found that anemia was associated with a delay in the initiation of the coagulation cascade with a finally formed clot with superior strength and viscoelastic properties. Transfusion of RBCs was associated with impaired clot quality, with even worse effects on the initial fibrin build‐up and clot quality by fresh RBCs.
- 1 April 2010
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 110 (4) , 987-994
In Normal Controls, Both Age and Gender Affect Coagulability as Measured by Thrombelastography
D in native whole blood and in recalcified citrated blood from 120 healthy adults (60 men and 60 women) with various ages and in an additional 29 healthy women using OCs. RESULTS: We observed hypercoagulability in women compared with men and in women using OCs compared with age-matched nonusers. Moreover, we found hypercoagulability with aging. Using the method of Bland and Altman (Lancet 1986;1:307–10), we demonstrated no correlation between TEG® measurements in native and recalcified citrated blood. CONCLUSIONS: Aging, female gender, use of OCs, and low-normal hematocrit levels have significant procoagulant effects. TEG® measurements in native and recalcified citrated blood are not interchangeable, as indicated by differences between the 2 measurements ranging from 20%in maximal amplitude to 246% in clotting time. Furthermore, the limits of agreement strongly exceeded clinical acceptability to conclude interchangeability....
- 1 April 2010
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 110 (4) , 987-994
In Normal Controls, Both Age and Gender Affect Coagulability as Measured by Thrombelastography
D in native whole blood and in recalcified citrated blood from 120 healthy adults (60 men and 60 women) with various ages and in an additional 29 healthy women using OCs. RESULTS: We observed hypercoagulability in women compared with men and in women using OCs compared with age-matched nonusers. Moreover, we found hypercoagulability with aging. Using the method of Bland and Altman (Lancet 1986;1:307–10), we demonstrated no correlation between TEG® measurements in native and recalcified citrated blood. CONCLUSIONS: Aging, female gender, use of OCs, and low-normal hematocrit levels have significant procoagulant effects. TEG® measurements in native and recalcified citrated blood are not interchangeable, as indicated by differences between the 2 measurements ranging from 20%in maximal amplitude to 246% in clotting time. Furthermore, the limits of agreement strongly exceeded clinical acceptability to conclude interchangeability....