MEMarius Simon Enstrup

Marius Simon Enstrup

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marius Simon Enstrup has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Ulrich Kunz

    Institute of Chemical and Electrochemical Process Engineering, Clausthal University of Technology, 38678 Clausthal-Zellerfeld, Germany

    2 shared publications
  • Annika Carolina Hoppe

    Department of Circular Economy Systems, Institute of Energy Process Engineering and Fuel Technology, Clausthal University of Technology, D-38678 Clausthal-Zellerfeld, Germany

    1 shared publication
  • Babak Dangpiaei

    Institute of Chemical and Electrochemical Process Engineering Clausthal University of Technology Leibnizstraße 17 38678 Clausthal-Zellerfeld Germany

    1 shared publication
  • Christine Minke

    Institute of Mineral and Waste Processing, Recycling and Circular Economy Systems, Clausthal University of Technology, 38678 Clausthal-Zellerfeld, Germany

    1 shared publication
  • Dennis Haupt

    CUTEC Research Center for Environmental Technologies, Clausthal University of Technology, 38678 Clausthal-Zellerfeld, Germany

    1 shared publication
  • Fabian Bienen

    Institute of Engineering Thermodynamics, German Aerospace Center, Pfaffenwaldring 38-40, 70569 Stuttgart, Germany

    1 shared publication

Latest Publications

  • Open Access

    Laundry Bleaching: Evaluating the Environmental Benefits of Automatic Dosing Systems with Electrochemical Reactors

    by Marius Simon Enstrup, Nick Blume, Nilay Sari, Lea Michelle Mook, Jan Witte, Annika Carolina Hoppe, Ulrich Kunz, Christine Minke


  • Open Access

    Influence of Water Hardness and Complexing Agents on Electrochemical Hydrogen Peroxide Generation

    by Marius Simon Enstrup, Jan Steinmann, Freyja Galina Daragan, Babak Dangpiaei, Ulrich Kunz

    Recently, many studies have been published regarding electrochemical oxygen reduction reaction for generating hydrogen peroxide (H2O2) using gas diffusion electrodes (GDEs) for various applications. Sodium salts solved in deionized water were usually used as supporting electrolytes. In technical applications, however, tap water‐based electrolytes with hardeners are particularly relevant and have only been considered in a few studies to date. In this work, we investigated the influence of hardeners on H2O2‐generation at 150 mA cm−2 and were able to show that scaling occurs predominantly on the GDE‐surface and not in its pore structure. With the novel method in electrochemical synthesis by using complexing agents to bind hardeners, we were able to significantly reduce the scaling. Even after 10 h of operation, the reactor still achieves a faradaic efficiency (FE) of above 70 % (>67 mg h−1 cm−2), comparable to the experiments without hardeners and complexing agents in the electrolyte. Furthermore, we demonstrate that the complexing agents are not electrochemically converted at the carbon‐based GDE and behave inertly. If the cell is operated with complexing agents and rinsed with acidic liquid (anolyte) between batches, scaling can be completely avoided.


  • Open Access

    Improving the Treatment Efficiency and Lowering the Operating Costs of Electrochemical Advanced Oxidation Processes

    by Thorben Muddemann, Rieke Neuber, Dennis Haupt, Tobias Graßl, Mohammad Issa, Fabian Bienen, Marius Enstrup, Jonatan Möller, Thorsten Matthée, Michael Sievers, et al.

    Electrochemical advanced oxidation processes (EAOP®) are promising technologies for the decentralized treatment of water and will be important elements in achieving a circular economy. To overcome the drawback of the high operational expenses of EAOP® systems, two novel reactors based on a next-generation boron-doped diamond (BDD) anode and a stainless steel cathode or a hydrogen-peroxide-generating gas diffusion electrode (GDE) are presented. This reactor design ensures the long-term stability of BDD anodes. The application potential of the novel reactors is evaluated with artificial wastewater containing phenol (COD of 2000 mg L−1); the reactors are compared to each other and to ozone and peroxone systems. The investigations show that the BDD anode can be optimized for a service life of up to 18 years, reducing the costs for EAOP® significantly. The process comparison shows a degradation efficiency for the BDD–GDE system of up to 135% in comparison to the BDD–stainless steel electrode combination, showing only 75%, 14%, and 8% of the energy consumption of the BDD–stainless steel, ozonation, and peroxonation systems, respectively. Treatment efficiencies of nearly 100% are achieved with both novel electrolysis reactors. Due to the current density adaptation and the GDE integration, which result in energy savings as well as the improvements that significantly extend the lifetime of the BDD electrode, less resources and raw materials are consumed for the power generation and electrode manufacturing processes.