MRMichael J. Rust

Michael J. Rust

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael J. Rust has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Andrew W. Browne

    From the *Department of Biomedical Engineering, Western New England University, Springfield, MA; † Internal Medicine, Harvard Medical School, Cambridge Hospital, Cambridge, MA; and ‡LAC+USC Medical Center, University of Southern California Keck School of Medicine, Los Angeles, CA

    1 shared publication
  • James H. PhD Nichols

    From the *Department of Biomedical Engineering, Western New England University; and †Department of Pathology, Tufts University School of Medicine, Baystate Health, Springfield, MA

    1 shared publication
  • Joseph T. Bs Papu

    From the *Department of Biomedical Engineering, Western New England University, Springfield, MA; † Internal Medicine, Harvard Medical School, Cambridge Hospital, Cambridge, MA; and ‡LAC+USC Medical Center, University of Southern California Keck School of Medicine, Los Angeles, CA

    1 shared publication
  • Nicholas A. Bs Carlson

    From the *Department of Biomedical Engineering, Western New England University; and †Department of Pathology, Tufts University School of Medicine, Baystate Health, Springfield, MA

    1 shared publication

Latest Publications

  • A Portable Centrifuge for Point-of-Care Measurement of Hematocrit in Low-Resource Settings

    by Joseph T. Bs Papu, Michael J. Rust, Andrew W. Browne

    A portable centrifuge was developed for point-of-care measurement of hematocrit in low-resource settings. The centrifuge consists of an electromechanical motor with performance optimized and controlled for centrifugal separation of blood in capillary tubes. The motor is powered by a set of rechargeable batteries and spins the samples at a controlled rate between 1000 and 15,000 revolutions per minute (RPM). Preliminary test results show that an accurate hematocrit reading can be made after operating the centrifuge for 110 seconds at 10,000 RPM. The centrifuge can be operated for almost three 8-hour work days at a 25% duty cycle when the batteries are fully charged, and it can measure hematocrits over the entire clinically relevant range with minimal experimental error. With a total system cost of less than $30, the portable centrifuge developed in this work has the potential to make a large impact on centrifugal separation applications such as the screening process for anemia in any clinical setting.


  • A Thermo-Modulating Container for Transport and Storage of Glucose Meters in a Cold Weather Environment

    by Michael J. Rust, Nicholas A. Bs Carlson, James H. PhD Nichols

    Background Point-of-care glucose meters are an important tool in assessing blood glucose levels and managing insulin dosage of diabetic patients. Glucose meters have been designed to operate in temperature-controlled environments, such as hospitals, and can be unsuitable for use in extreme conditions found in an ambulatory setting. A thermo-modulating container was developed to prevent glucose meter low-temperature errors. Methods The device was designed to maintain the operating temperature of a professional model glucose meter within the range specified by the manufacturer (15°C–40°C). The container consisted of a hard outer shell with insulation, thermostat, and heating elements. The glucose meter was placed inside the container and subjected to environmental temperatures ranging from −15°C to 15°C. Results When used in passive configuration at an environmental temperature of 10°C, the container extended the operating time of the glucose meter from 1 hour to 7 hours before receiving a temperature error. When used in the active configuration at the same temperature, the container extended the operating time to 24 hours. This sequence of tests was repeated at an extreme temperature condition (−15°C), with the container extending device operation from under 10 minutes to 38 and 251 minutes using passive and active modes, respectively. Conclusions The device provides significant protection against glucose meter low-temperature errors. As a result, the container may be applied for transportation and storage of glucose meters in a cold weather ambulatory setting.