Amedeo Caprino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amedeo Caprino has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Filippo Lorenzoni
University of Padova
3 shared publications - Francesca da Porto
Department of Geosciences, University of Padova, Padova, Italy
3 shared publications - Alexandra Chavarría Arnau
Medieval Archaeology, University of Padova
1 shared publication - Gian Pietro Brogiolo
Universitá Degli Studi di Padova (University of Padua)
1 shared publication - Gianmarco Bonaldo
Department of Geosciences, University of Padova, via Gradenigo 6, 35131 Padova, Italy
1 shared publication - Laura Carnieletto
University of Padua, Padova, 35131, Italy
1 shared publication
Latest Publications
- Open Access
Dynamic-Based Limit Analysis for Seismic Assessment of Free-Standing Walls of San Giovanni Church in Castelseprio UNESCO World Heritage Site
Free-standing archaeological walls are significantly exposed to horizontal actions (e.g., earthquakes) as they lack connections provided by floors or roofs. In such cases, the dynamic response governs the activation of local mechanisms of collapse, determining the shape of the macroblocks and their position. Engineering models of archaeological walls are developed according to the results of extensive visual inspections and on-site testing, including modal identification for calibration purposes. A modal response spectrum analysis on the calibrated model identifies the zones where the tensile stress is exceeded, which are more likely to detach as rigid macroblocks and subsequently overturn due to the expected ground spectra. The macroblocks are then assessed according to limit analysis. The case studies are the north and the apse walls of the church of San Giovanni Evangelista in Castelseprio (Varese, Lombardy), a 5th century Longobard fortified settlement, a part of UNESCO World Heritage. The construction quality of the apse was poorer than the north wall, but the masonry of both is very compact thanks to the good mortar. The macroblocks are identified mostly in the upper crests of the walls, and their acceleration of activation is two to six times larger than the demand (considering the dynamic amplification that the structure applies to the ground motion); therefore, no particular intervention is needed. The proposed method will require additional calibration, e.g., through nonlinear dynamic analyses, and a more precise treatment of uncertainties in masonry mechanical properties to determine the shape of the macroblocks.
Open AccessDynamic-Based Limit Analysis for Seismic Assessment of Free-Standing Walls of San Giovanni Church in Castelseprio UNESCO World Heritage Site
Free-standing archaeological walls are significantly exposed to horizontal actions (e.g., earthquakes) as they lack connections provided by floors or roofs. In such cases, the dynamic response governs the activation of local mechanisms of collapse, determining the shape of the macroblocks and their position. Engineering models of archaeological walls are developed according to the results of extensive visual inspections and on-site testing, including modal identification for calibration purposes. A modal response spectrum analysis on the calibrated model identifies the zones where the tensile stress is exceeded, which are more likely to detach as rigid macroblocks and subsequently overturn due to the expected ground spectra. The macroblocks are then assessed according to limit analysis. The case studies are the north and the apse walls of the church of San Giovanni Evangelista in Castelseprio (Varese, Lombardy), a 5th century Longobard fortified settlement, a part of UNESCO World Heritage. The construction quality of the apse was poorer than the north wall, but the masonry of both is very compact thanks to the good mortar. The macroblocks are identified mostly in the upper crests of the walls, and their acceleration of activation is two to six times larger than the demand (considering the dynamic amplification that the structure applies to the ground motion); therefore, no particular intervention is needed. The proposed method will require additional calibration, e.g., through nonlinear dynamic analyses, and a more precise treatment of uncertainties in masonry mechanical properties to determine the shape of the macroblocks.
- Open Access
- 14 March 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (6) , 1587
Satellite SAR Interferometry and On-Site Traditional SHM to Monitor the Post-Earthquake Behavior of the Civic Tower in L’Aquila (Abruzzo Region, Italy)
Structural Health Monitoring (SHM) represents a very powerful tool to assess the health condition of buildings. In recent years, the growing availability of high-resolution SAR satellite images has made possible the application of multi-temporal Interferometric Synthetic Aperture Radar (MT-InSAR) techniques for structural monitoring purposes, with high precision, low costs, timesaving, and the possibility to investigate wide areas. However, a comprehensive validation of the effectiveness of MT-InSAR in this application field has not been achieved yet. For this reason, in this paper a comparison between interferometric data and on-site measurement of displacements is proposed. The application case study is the Civic Tower of the city of L’Aquila (Abruzzo Region, Italy). After the seismic events that affected the area in 2009, an on-site monitoring system was installed on the tower to detect any changes in the damage pattern in the period 2010–2013. Furthermore, images acquired by COSMO-SkyMed constellation in Stripmap mode (~3 m resolution) during the same period were processed by the Permanent Scatterer-InSAR (PSI) technique to estimate the deformation of the structure and the surrounding area. The obtained results indicate that both methods are consistent in the measurement of displacement trends of the building and a slight rotation/displacement of the tower was detected. Such evidence highlights both the huge potential and the limitations of using InSAR techniques for SHM.
- 14 March 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (6) , 1587
Open AccessSatellite SAR Interferometry and On-Site Traditional SHM to Monitor the Post-Earthquake Behavior of the Civic Tower in L’Aquila (Abruzzo Region, Italy)
Structural Health Monitoring (SHM) represents a very powerful tool to assess the health condition of buildings. In recent years, the growing availability of high-resolution SAR satellite images has made possible the application of multi-temporal Interferometric Synthetic Aperture Radar (MT-InSAR) techniques for structural monitoring purposes, with high precision, low costs, timesaving, and the possibility to investigate wide areas. However, a comprehensive validation of the effectiveness of MT-InSAR in this application field has not been achieved yet. For this reason, in this paper a comparison between interferometric data and on-site measurement of displacements is proposed. The application case study is the Civic Tower of the city of L’Aquila (Abruzzo Region, Italy). After the seismic events that affected the area in 2009, an on-site monitoring system was installed on the tower to detect any changes in the damage pattern in the period 2010–2013. Furthermore, images acquired by COSMO-SkyMed constellation in Stripmap mode (~3 m resolution) during the same period were processed by the Permanent Scatterer-InSAR (PSI) technique to estimate the deformation of the structure and the surrounding area. The obtained results indicate that both methods are consistent in the measurement of displacement trends of the building and a slight rotation/displacement of the tower was detected. Such evidence highlights both the huge potential and the limitations of using InSAR techniques for SHM.
- Open Access
- 21 February 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (5) , 1177
Monitoring Displacements and Damage Detection through Satellite MT-InSAR Techniques: A New Methodology and Application to a Case Study in Rome (Italy)
Satellite interferometry has recently developed as a powerful tool for monitoring displacements on structures for structural health monitoring (SHM), as it allows obtaining information on past deformation and performing back analysis on structural behavior. Despite the increasing literature on this subject, the lack of protocols for applying and interpreting interferometric data for structural assessment prevents these techniques from being employed alongside conventional SHM. This paper proposes a methodology for exploiting satellite interferometric data aiming at remotely detecting displacements and buildings’ criticalities at different levels of analysis, i.e., urban scale and single-building scale. Moreover, this research exploits the capability of satellite monitoring for damage diagnosis, comparing the millimeter scale displacements to information derived from on-site inspections. Different data-driven algorithms were applied to detect seasonal and irreversible components of displacements, such as statistical models for damage identification derived from traditional on-site monitoring. Thus, the proposed methodology was applied to a XVI-century case study located in the city center of Rome (Italy), Palazzo Primoli, and two stocks of COSMO-SkyMed (CSK) images processed through the Small BAseline Subset Differential Interferometry (SBAS-DInSAR) technique were used to assess displacements for an eight-year-long (between 2011 and 2019) monitoring period.
- 21 February 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (5) , 1177
Open AccessMonitoring Displacements and Damage Detection through Satellite MT-InSAR Techniques: A New Methodology and Application to a Case Study in Rome (Italy)
Satellite interferometry has recently developed as a powerful tool for monitoring displacements on structures for structural health monitoring (SHM), as it allows obtaining information on past deformation and performing back analysis on structural behavior. Despite the increasing literature on this subject, the lack of protocols for applying and interpreting interferometric data for structural assessment prevents these techniques from being employed alongside conventional SHM. This paper proposes a methodology for exploiting satellite interferometric data aiming at remotely detecting displacements and buildings’ criticalities at different levels of analysis, i.e., urban scale and single-building scale. Moreover, this research exploits the capability of satellite monitoring for damage diagnosis, comparing the millimeter scale displacements to information derived from on-site inspections. Different data-driven algorithms were applied to detect seasonal and irreversible components of displacements, such as statistical models for damage identification derived from traditional on-site monitoring. Thus, the proposed methodology was applied to a XVI-century case study located in the city center of Rome (Italy), Palazzo Primoli, and two stocks of COSMO-SkyMed (CSK) images processed through the Small BAseline Subset Differential Interferometry (SBAS-DInSAR) technique were used to assess displacements for an eight-year-long (between 2011 and 2019) monitoring period.
- Open Access
- 26 August 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (17) , 9592
Integrated Seismic and Energy Retrofit Interventions on a URM Masonry Building: The Case Study of the Former Courthouse in Fabriano
Following the 2016 central Italy earthquakes, the high seismic vulnerability of existing buildings is once again at the center of the debate. Indeed, the majority of the Italian building stock (around 60%) was built before adopting the first seismic provisions (1974) and in a territory entirely characterized by medium to high levels of seismic hazard. On the other hand, the first provisions addressing thermal performance criteria were introduced in 1976 but with limited impact. A consistent reduction in energy consumption was further achieved in 1991, when even more buildings were erected. As a consequence, the Italian building stock is characterized by reduced seismic capacity and poor energy efficiency and, to optimize the available resources, combined retrofit interventions approaches are required. In this context, a synergic strategy for the seismic and energy retrofit of a unreinforced masonry (URM) building was proposed. The former Courthouse in Fabriano (Ancona, Marche), a strategic, three-story, unreinforced masonry building in the network of permanent monitoring systems of the Italian Department of Civil Protection, was selected as a case study. The overall effectiveness of various solutions of combined structural refurbishment and energy retrofit interventions, having different levels of invasiveness on the building, was assessed. In addition, a common methodology based on the expected annual losses allowed evaluating the financial feasibility of the proposed integrated interventions and estimating the changes in the return of the retrofitting investment in various seismic and climate zones. The results also show how the payback period could be significantly reduced by incentives and regulatory frameworks that currently favour the execution of integrated interventions.
- 26 August 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (17) , 9592
Open AccessIntegrated Seismic and Energy Retrofit Interventions on a URM Masonry Building: The Case Study of the Former Courthouse in Fabriano
Following the 2016 central Italy earthquakes, the high seismic vulnerability of existing buildings is once again at the center of the debate. Indeed, the majority of the Italian building stock (around 60%) was built before adopting the first seismic provisions (1974) and in a territory entirely characterized by medium to high levels of seismic hazard. On the other hand, the first provisions addressing thermal performance criteria were introduced in 1976 but with limited impact. A consistent reduction in energy consumption was further achieved in 1991, when even more buildings were erected. As a consequence, the Italian building stock is characterized by reduced seismic capacity and poor energy efficiency and, to optimize the available resources, combined retrofit interventions approaches are required. In this context, a synergic strategy for the seismic and energy retrofit of a unreinforced masonry (URM) building was proposed. The former Courthouse in Fabriano (Ancona, Marche), a strategic, three-story, unreinforced masonry building in the network of permanent monitoring systems of the Italian Department of Civil Protection, was selected as a case study. The overall effectiveness of various solutions of combined structural refurbishment and energy retrofit interventions, having different levels of invasiveness on the building, was assessed. In addition, a common methodology based on the expected annual losses allowed evaluating the financial feasibility of the proposed integrated interventions and estimating the changes in the return of the retrofitting investment in various seismic and climate zones. The results also show how the payback period could be significantly reduced by incentives and regulatory frameworks that currently favour the execution of integrated interventions.