Francesca Bennet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francesca Bennet has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Vasile-Dan Hodoroaba
Federal Institute for Materials Research and Testing (BAM)
2 shared publications - Alexander Roloff
Department of Chemical and Product Safety, German Federal Institute for Risk Assessment, Berlin, Germany
1 shared publication - Alexis Franquet
Imec 2 , Kapeldreef 75, Leuven 3001
1 shared publication - Allen T. Bellew
School of Chemistry, Trinity College Dublin, Dublin 2, Ireland
1 shared publication - Anna Belu
Medtronic Corporate Science and Technology 5 , 710 Medtronic Parkway, Mailstop LT240, Minneapolis, Minnesota 55432
1 shared publication Arnaud Delcorte
Institute of Condensed Matter and Nanosciences - Bio & Soft Matter, Surface Characterisation, Université catholique de Louvain 8 , Place Louis Pasteur, 1 bte L4.01.10, Louvain-la-Neuve B-1348, Belgium
1 shared publication
Latest Publications
- Open Access
- 16 August 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 41 (5)
VAMAS TWA2 interlaboratory comparison: Surface analysis of TiO2 nanoparticles using ToF-SIMS
Due to the extremely high specific surface area of nanoparticles and corresponding potential for adsorption, the results of surface analysis can be highly dependent on the history of the particles, particularly regarding sample preparation and storage. The sample preparation method has, therefore, the potential to have a significant influence on the results. This report describes an interlaboratory comparison (ILC) with the aim of assessing which sample preparation methods for ToF-SIMS analysis of nanoparticles provided the most intra- and interlaboratory consistency and the least amount of sample contamination. The BAM reference material BAM-P110 (TiO2 nanoparticles with a mean Feret diameter of 19 nm) was used as a sample representing typical nanoparticles. A total of 11 participants returned ToF-SIMS data, in positive and (optionally) negative polarity, using sample preparation methods of “stick-and-go” as well as optionally “drop-dry” and “spin-coat.” The results showed that the largest sources of variation within the entire data set were caused by adventitious hydrocarbon contamination or insufficient sample coverage, with the spin-coating protocol applied in this ILC showing a tendency toward insufficient sample coverage; the sample preparation method or the participant had a lesser influence on results.
- 16 August 2023
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 41 (5)
Open AccessVAMAS TWA2 interlaboratory comparison: Surface analysis of TiO2 nanoparticles using ToF-SIMS
Due to the extremely high specific surface area of nanoparticles and corresponding potential for adsorption, the results of surface analysis can be highly dependent on the history of the particles, particularly regarding sample preparation and storage. The sample preparation method has, therefore, the potential to have a significant influence on the results. This report describes an interlaboratory comparison (ILC) with the aim of assessing which sample preparation methods for ToF-SIMS analysis of nanoparticles provided the most intra- and interlaboratory consistency and the least amount of sample contamination. The BAM reference material BAM-P110 (TiO2 nanoparticles with a mean Feret diameter of 19 nm) was used as a sample representing typical nanoparticles. A total of 11 participants returned ToF-SIMS data, in positive and (optionally) negative polarity, using sample preparation methods of “stick-and-go” as well as optionally “drop-dry” and “spin-coat.” The results showed that the largest sources of variation within the entire data set were caused by adventitious hydrocarbon contamination or insufficient sample coverage, with the spin-coating protocol applied in this ILC showing a tendency toward insufficient sample coverage; the sample preparation method or the participant had a lesser influence on results.
- Open Access
- 8 June 2021
- Published by Wiley in ChemElectroChem
- Vol. 8 (13) , 2597-2606
Electrochemical Immunomagnetic Ochratoxin A Sensing: Steps Forward in the Application of 3,3’,5,5’‐Tetramethylbenzidine in Amperometric Assays
Electrochemical methods offer great promise in meeting the demand for user‐friendly on‐site devices for monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme‐linked immunosorbent assays, with photometric detection of 3,3’,5,5’‐tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphone‐based, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis for sensing of further analytes.
- 8 June 2021
- Published by Wiley in ChemElectroChem
- Vol. 8 (13) , 2597-2606
Open AccessElectrochemical Immunomagnetic Ochratoxin A Sensing: Steps Forward in the Application of 3,3’,5,5’‐Tetramethylbenzidine in Amperometric Assays
Electrochemical methods offer great promise in meeting the demand for user‐friendly on‐site devices for monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme‐linked immunosorbent assays, with photometric detection of 3,3’,5,5’‐tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphone‐based, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis for sensing of further analytes.
- Open Access
- 1 June 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1953 (1) , 012002
Towards a method for quantitative evaluation of nanoparticle from suspensions via microarray printing and SEM analysis
As part of the development of a library of accurate and efficient methods for measurement of nanoparticle properties, we develop and optimize a method for the efficient analysis of nanoparticle size distribution from suspensions via microprinting and digital analysis of electron microscopy (SEM and TEM) images, with the ultimate aim of automated quantitative concentration analysis (calculated from drop volume). A series of different nanoparticle suspensions (gold, latex, and SiO2 in varying sizes and concentrations) were printed onto TEM grids in a 4 x 4 array in the concentration range 7×108 to 1×1011 nanoparticles/mL and imaged with SEM. Concentrations and printing conditions (temperature, relative humidity) were varied in order to minimize the coffee-ring effect.
- 1 June 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1953 (1) , 012002
Open AccessTowards a method for quantitative evaluation of nanoparticle from suspensions via microarray printing and SEM analysis
As part of the development of a library of accurate and efficient methods for measurement of nanoparticle properties, we develop and optimize a method for the efficient analysis of nanoparticle size distribution from suspensions via microprinting and digital analysis of electron microscopy (SEM and TEM) images, with the ultimate aim of automated quantitative concentration analysis (calculated from drop volume). A series of different nanoparticle suspensions (gold, latex, and SiO2 in varying sizes and concentrations) were printed onto TEM grids in a 4 x 4 array in the concentration range 7×108 to 1×1011 nanoparticles/mL and imaged with SEM. Concentrations and printing conditions (temperature, relative humidity) were varied in order to minimize the coffee-ring effect.