Yusuke Iwano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yusuke Iwano has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Eijun Sueyoshi
Department of Radiological Sciences, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan
1 shared publication - Hirofumi Koike
Department of Radiology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki University School of Medicine, Nagasaki, Japan
1 shared publication - Koji Maemura
Department of Cardiovascular Medicine, Nagasaki University Graduate School of Biomedical Sciences
1 shared publication - Masataka Uetani
Department of Radiology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
1 shared publication - Taiga Oka
Department of Radiology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki University School of Medicine, Nagasaki, Japan
1 shared publication - Takamasa Nishimura
Department of Radiology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki University School of Medicine, Nagasaki, Japan
1 shared publication
Latest Publications
- 30 August 2021
- Published by Springer Nature in Lung
- Vol. 199 (5) , 475-483
Effect of Balloon Pulmonary Angioplasty on Homogenization of Lung Perfusion Blood Volume by Dual-Energy Computed Tomography in Patients with Chronic Thromboembolic Pulmonary Hypertension
Objective Balloon pulmonary angioplasty (BPA) is used to treat patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH); the goal is to improve pulmonary perfusion. We aimed to evaluate lung perfusion blood volume (PBV) with haemodynamic and exercise-capacity parameters to assess the efficacy of BPA in the treatment of CTEPH. Methods We retrospectively studied 33 patients over a 6-year period. DECT pulmonary angiography was performed before and after BPA. DECT provided iodine distribution maps; whole-lung and regional PBV images and quantification were generated using post-processing software. A mosaic pattern suggesting perfusion inhomogeneity is typical in CTEPH. Hypothetically, BPA treatment would promote homogenization that would be reflected in the calculated standard deviation. Results Lung perfusion images showed decreased heterogeneity after BPA. There was a significant difference before and after BPA in the whole-lung PBV and in the regional standard deviation for pulmonary arterial pressure (R = 0.37, p = 0.032 and R = 0.57, p = 0.006), pulmonary vascular resistance (R = 0.51, p = 0.023 and R = 0.60, p = 0.002), transtricuspid pressure gradient (R = 0.50, p = 0.0028 and R = 0.61, p = 0.0001), brain natriuretic peptide (R = 0.54, p = 0.0012 and R = 0.46, p = 0.0078), and 6-min walking distance (R = 0.59, p = 0.003 and R = 0.26, p = 0.14). The effects were especially pronounced after the first BPA procedure. Conclusion Decreased lung heterogeneity may suggest BPA efficacy in treating CTEPH. After BPA treatment, improved lung PBV and improved regional standard deviation showed a strong positive correlation with haemodynamic parameters and exercise capacity, which also suggests that BPA is effective in treating CTEPH.
- 30 August 2021
- Published by Springer Nature in Lung
- Vol. 199 (5) , 475-483
Effect of Balloon Pulmonary Angioplasty on Homogenization of Lung Perfusion Blood Volume by Dual-Energy Computed Tomography in Patients with Chronic Thromboembolic Pulmonary Hypertension
Objective Balloon pulmonary angioplasty (BPA) is used to treat patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH); the goal is to improve pulmonary perfusion. We aimed to evaluate lung perfusion blood volume (PBV) with haemodynamic and exercise-capacity parameters to assess the efficacy of BPA in the treatment of CTEPH. Methods We retrospectively studied 33 patients over a 6-year period. DECT pulmonary angiography was performed before and after BPA. DECT provided iodine distribution maps; whole-lung and regional PBV images and quantification were generated using post-processing software. A mosaic pattern suggesting perfusion inhomogeneity is typical in CTEPH. Hypothetically, BPA treatment would promote homogenization that would be reflected in the calculated standard deviation. Results Lung perfusion images showed decreased heterogeneity after BPA. There was a significant difference before and after BPA in the whole-lung PBV and in the regional standard deviation for pulmonary arterial pressure (R = 0.37, p = 0.032 and R = 0.57, p = 0.006), pulmonary vascular resistance (R = 0.51, p = 0.023 and R = 0.60, p = 0.002), transtricuspid pressure gradient (R = 0.50, p = 0.0028 and R = 0.61, p = 0.0001), brain natriuretic peptide (R = 0.54, p = 0.0012 and R = 0.46, p = 0.0078), and 6-min walking distance (R = 0.59, p = 0.003 and R = 0.26, p = 0.14). The effects were especially pronounced after the first BPA procedure. Conclusion Decreased lung heterogeneity may suggest BPA efficacy in treating CTEPH. After BPA treatment, improved lung PBV and improved regional standard deviation showed a strong positive correlation with haemodynamic parameters and exercise capacity, which also suggests that BPA is effective in treating CTEPH.