JPJérôme Petit

Jérôme Petit

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jérôme Petit has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Clément Batteux

    Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, Centre de Référence Cardiopathies Congénitales Complexes M3C, Faculté de Médecine, Université Paris Saclay, BME Lab, 92350 Le Plessis-Robinson, France

    3 shared publications
  • Clément Karsenty

    CHU de Toulouse, Toulouse, France

    3 shared publications
  • Sébastien Hascoët

    Congenital Heart Diseases, M3C Rare Diseases Network, Hôpital Marie‑Lannelongue, France

    3 shared publications
  • Florence Lecerf

    Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, Centre de Référence Cardiopathies Congénitales Complexes M3C, Faculté de Médecine, Université Paris Saclay, BME Lab, 92350 Le Plessis-Robinson, France

    2 shared publications
  • Ali Houeijeh

    Institut CŒUR Poumon

    1 shared publication
  • Ali Houeijeh

    Department of Congenital Heart Disease, Marie Lannelongue Hospital, BME lab, Centre Constitutif Réseau M3C Cardiopathies Congénitales Complexes, Groupe Hospitalier Paris Saint Joseph, Faculté de Médecine, Université Paris-Saclay, 133 avenue de la résistance, 92350 Le Plessis Robinson, France; Department of Congenital Heart Disease, Lille University Hospital, Faculté de médecine, Laboratoire EA4489, Université Lille II, Lille, France

    1 shared publication

Latest Publications

  • Open Access

    A Modified Technique for Transcatheter Pulmonary Valve Implantation of SAPIEN 3 Valves in Large Right Ventricular Outflow Tract: A Matched Comparison Study

    by Ali Houeijeh, Clément Karsenty, Nicolas Combes, Clément Batteux, Florence Lecerf, Frederic Remy, Estibaliz Valdeolmillos, Jérôme Petit, Sébastien Hascoet

    Introduction: Percutaneous pulmonary valve implantation (PPVI) with a SAPIEN 3 valve is effective for treating treat right ventricle outflow (RVOT) dysfunction. A modified technique was developed without prestenting using a protective valve delivery method. We aimed to compare the procedural results of the modified technique group (MTG) to those of patients in a conventional technique group (CTG). Methods: We designed a matched before–after study. All consecutive PPVI with SAPIEN 3 performed in the MTG over 9 months were matched, based on the RVOT type and size, to consecutive procedures performed previously with SAPIEN 3. Results: A total of 54 patients were included, equally distributed in the two groups. The sizes of the SAPIEN 3 valves were 23 mm (n = 9), 26 mm (n = 9), 29 mm (n = 36). The two groups were similar regarding demographic data, RVOT type, and pre-procedure hemodynamics. PPVI was performed in a single procedure in all patients of the MTG, whereas six (22.2%) patients of the CTG group underwent prestenting as a first step and valve implantation later (p = 0.02). The procedures were successful in all cases. Stent embolization was reported in two patients (7.4%) in the CTG, which were impacted in pulmonary arteries. In one case (3.7%), in the MTG, an unstable 29 mm SAPIEN 3 valve was stabilized with two stents and additional valve-in-valve implantation. The hemodynamics results were good in all cases, without significant differences between the two groups. The procedures’ durations and fluoroscopy times were significantly reduced in the MTG (48.1 versus 82.6 min, p < 0.0001; 15.2 versus 29.8 min, p = 0.0002). During follow-up, neither stent fracture nor valve dysfunction was noticed in either group. Conclusion: PPVI without prestenting and with a protective delivery method of the SAPIEN 3 valve significantly reduces the procedure’s complexity, the duration, and the irradiation while maintaining excellent hemodynamics results in selected cases.


  • Long-term outcomes of transcatheter pulmonary valve implantation with melody and SAPIEN valves

    by Ali Houeijeh, Clement Batteux, Clement Karsenty, Nassima Ramdane, Florence Lecerf, Estibaliz Valdeolmillos, Julie Lourtet-Hascoet, Sarah Cohen, Emre Belli, Jérôme Petit, et al.


  • Sinus Venosus ASDs: Imaging and Percutaneous Closure

    by C. Batteux, A. Azarine, C. Karsenty, J Petit, V. Ciobotaru, P. Brenot, S. Hascoet

    Purpose of the review Percutaneous closure of sinus venosus atrial septal defects (ASD) using covered stent implantation is a new and promising minimally invasive technique. New imaging tools are used to ensure preoperative anatomical characterization and preoperative guidance, which are key procedural success factors. Here we will describe and analyze these recent developments. Recent findings Sinus venosus ASDs present a wide variety of anatomical features which must be described and analyzed using various imaging tools, including 3D technology. Percutaneous closure is challenging, but can hasten clinical recovery compared to the gold-standard conventional open-heart surgery. The feasibility of percutaneous closure relies on precise preoperative anatomical study and on real-time guidance using a multimodal fusion imaging process. Summary Three-dimensional modeling of sinus venosus ASD is essential to understand the large anatomical panel encountered in this pathology. Multimodal fusion imaging guidance is very useful for performing sinus venosus ASD percutaneous closure in selected patients.