Craig Divine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Craig Divine has a total of 173 co-authors. Here are the top co-authors by number of shared publications:
Jesse Wright
6 shared publicationsDavid Liles
Arcadis US, Inc, United States
4 shared publicationsKathleen Gerber
Vandenberg Space Force Base, 1028 Iceland Ave,Bldg 11432, Vandenberg, CA 93347 USA
4 shared publicationsMichael Kladias
Arcadis US Nixa Missouri USA
4 shared publicationsShandra Justicia‐León
4 shared publicationsAndy Baumeister
Arcadis US, Inc, United States
3 shared publications
Latest Publications
- 1 September 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (4) , 10-24
Advances in Remediation: Recharge Redux
- 1 September 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (4) , 10-24
Advances in Remediation: Recharge Redux
- 1 June 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (3) , 12-20
Advances in Remediation: Karst, PFAS and Microplastics—A Complexus Nexus
- 1 June 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (3) , 12-20
Advances in Remediation: Karst, PFAS and Microplastics—A Complexus Nexus
- 22 May 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (3) , 66-81
Vertebrae™ Segmented Horizontal Wells for Monitoring PFAS Contaminant Mass Flux and Discharge
Quantifying contaminant mass flux and plume mass discharge is essential for flux‐based management of per‐ and polyfluoroalkyl substances (PFAS), yet few monitoring technologies provide the spatial resolution, repeatability, and cost efficiency needed for long‐term application. Many PFAS plumes originating from discrete source areas exhibit high width‐to‐thickness ratios driven by recharge‐dominated transport, weak vertical dispersion, and hydraulic conductivity anisotropy, limiting the effectiveness of conventional vertical transects for control‐plane discharge assessment. This study evaluated the Vertebrae™ Well System (VWS), a segmented, nested horizontal multi‐screen technology, for quantifying groundwater flux and perfluorooctane sulfonate (PFOS) mass discharge under relatively homogeneous aquifer hydraulic conditions at the Grayling Army Airfield (GAAF) in northern Michigan, USA. Two 500‐feet VWS arrays were installed downgradient of a former aqueous film‐forming foam source area, oriented perpendicular to groundwater flow. Vertical placement was informed by prior high‐resolution characterization. Groundwater flux was quantified using multiple independent methods, including hydraulic profiling, tracer testing, active distributed temperature sensing, and grain‐size‐based permeability estimation, and integrated with PFOS concentrations across eight performance monitoring (PM) events. Geostatistical interpolation was used to support transect‐scale flux and discharge integration in an unconfined sandy aquifer. Results indicate consistent spatial patterns and reproducibility across methods, with cross‐method agreement within expected field‐scale variability, supporting the interpretation that segmented horizontal wells can capture subtle lateral flux variability within the groundwater table fluctuation zone and quantify plume‐scale PFOS mass discharge with high spatial and temporal resolution. Horizontal multi‐screen systems provided repeatable, spatially resolved estimates of groundwater flux and PFOS mass discharge when screen placement targeted dominant concentration and groundwater flow horizons. These findings highlight the utility of segmented horizontal wells for flux‐based remediation evaluation, regulatory decision‐making, and long‐term performance monitoring at PFAS‐impacted sites.
- 22 May 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (3) , 66-81
Vertebrae™ Segmented Horizontal Wells for Monitoring PFAS Contaminant Mass Flux and Discharge
Quantifying contaminant mass flux and plume mass discharge is essential for flux‐based management of per‐ and polyfluoroalkyl substances (PFAS), yet few monitoring technologies provide the spatial resolution, repeatability, and cost efficiency needed for long‐term application. Many PFAS plumes originating from discrete source areas exhibit high width‐to‐thickness ratios driven by recharge‐dominated transport, weak vertical dispersion, and hydraulic conductivity anisotropy, limiting the effectiveness of conventional vertical transects for control‐plane discharge assessment. This study evaluated the Vertebrae™ Well System (VWS), a segmented, nested horizontal multi‐screen technology, for quantifying groundwater flux and perfluorooctane sulfonate (PFOS) mass discharge under relatively homogeneous aquifer hydraulic conditions at the Grayling Army Airfield (GAAF) in northern Michigan, USA. Two 500‐feet VWS arrays were installed downgradient of a former aqueous film‐forming foam source area, oriented perpendicular to groundwater flow. Vertical placement was informed by prior high‐resolution characterization. Groundwater flux was quantified using multiple independent methods, including hydraulic profiling, tracer testing, active distributed temperature sensing, and grain‐size‐based permeability estimation, and integrated with PFOS concentrations across eight performance monitoring (PM) events. Geostatistical interpolation was used to support transect‐scale flux and discharge integration in an unconfined sandy aquifer. Results indicate consistent spatial patterns and reproducibility across methods, with cross‐method agreement within expected field‐scale variability, supporting the interpretation that segmented horizontal wells can capture subtle lateral flux variability within the groundwater table fluctuation zone and quantify plume‐scale PFOS mass discharge with high spatial and temporal resolution. Horizontal multi‐screen systems provided repeatable, spatially resolved estimates of groundwater flux and PFOS mass discharge when screen placement targeted dominant concentration and groundwater flow horizons. These findings highlight the utility of segmented horizontal wells for flux‐based remediation evaluation, regulatory decision‐making, and long‐term performance monitoring at PFAS‐impacted sites.
- 11 April 2026
- Published by Wiley in Groundwater Monitoring & Remediation
Reactive Core Matting ( RCM ) to Passively Treat PFAS ‐Impacted Groundwater Discharging to a Small Stream
Groundwater near a former fire training area (FTA) discharges to a nearby small perennial stream and is impacted by per‐ and polyfluoroalkyl substances (PFAS), including (generally listed in order from highest to lowest concentrations): perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorohexanesulfonic acid (PFHxS), perfluorohexanoic acid (PFHxA), perfluorobutanesulfonic acid (PFBS), and perfluorobutanoic acid (PFBA). Upstream of the FTA, total PFAS (i.e., the sum of PFAS measured by United States Environmental Protection Agency [USEPA] Method 537.1, or Σ 24 PFAS) concentrations in the stream are about 10,000 ng/L resulting from various other PFAS sources, however, after passing by a 400‐feet long reach adjacent to the FTA, in‐stream Σ 24 PFAS concentration increase by an average of about 15,000 ng/L as a result of the discharge of impacted groundwater (the average Σ 24 PFAS mass discharge from groundwater is estimated at about 5.0 g/d. Reactive core matting (RCM) consisting of adsorptive media (FLUORO‐SORB ® 200) woven between two layers of permeable geo‐fabric was installed along a targeted reach of the stream to passively remove PFAS from discharging groundwater. Nine quarterly performance monitoring events, which included measurements of streamflow, and porewater and surface water concentrations, were conducted over a 2.4‐year performance period. The RCM was highly successful in reducing Σ 24 PFAS mass discharging from groundwater to the stream, removing an estimated 8.2 kg of Σ 24 PFAS, which represents nearly all PFAS mass discharging from groundwater. The stream treatment values (calculated from the increase in concentration over the reach after RCM installation compared to baseline) were relatively high and consistent, all averaging over 80%. However, some PFAS (notably PFBA, PFBS, PFHxA, and PFHxS) show a slight decline in stream treatment values for the last two monitoring events, possibly indicating treatment efficiency may have begun to decline for these specific PFAS. This work highlights both the practical implementability and efficacy of this technology, and therefore, RCMs are recommended for consideration at other similar PFAS‐impacted sites.
- 11 April 2026
- Published by Wiley in Groundwater Monitoring & Remediation
Reactive Core Matting ( RCM ) to Passively Treat PFAS ‐Impacted Groundwater Discharging to a Small Stream
Groundwater near a former fire training area (FTA) discharges to a nearby small perennial stream and is impacted by per‐ and polyfluoroalkyl substances (PFAS), including (generally listed in order from highest to lowest concentrations): perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorohexanesulfonic acid (PFHxS), perfluorohexanoic acid (PFHxA), perfluorobutanesulfonic acid (PFBS), and perfluorobutanoic acid (PFBA). Upstream of the FTA, total PFAS (i.e., the sum of PFAS measured by United States Environmental Protection Agency [USEPA] Method 537.1, or Σ 24 PFAS) concentrations in the stream are about 10,000 ng/L resulting from various other PFAS sources, however, after passing by a 400‐feet long reach adjacent to the FTA, in‐stream Σ 24 PFAS concentration increase by an average of about 15,000 ng/L as a result of the discharge of impacted groundwater (the average Σ 24 PFAS mass discharge from groundwater is estimated at about 5.0 g/d. Reactive core matting (RCM) consisting of adsorptive media (FLUORO‐SORB ® 200) woven between two layers of permeable geo‐fabric was installed along a targeted reach of the stream to passively remove PFAS from discharging groundwater. Nine quarterly performance monitoring events, which included measurements of streamflow, and porewater and surface water concentrations, were conducted over a 2.4‐year performance period. The RCM was highly successful in reducing Σ 24 PFAS mass discharging from groundwater to the stream, removing an estimated 8.2 kg of Σ 24 PFAS, which represents nearly all PFAS mass discharging from groundwater. The stream treatment values (calculated from the increase in concentration over the reach after RCM installation compared to baseline) were relatively high and consistent, all averaging over 80%. However, some PFAS (notably PFBA, PFBS, PFHxA, and PFHxS) show a slight decline in stream treatment values for the last two monitoring events, possibly indicating treatment efficiency may have begun to decline for these specific PFAS. This work highlights both the practical implementability and efficacy of this technology, and therefore, RCMs are recommended for consideration at other similar PFAS‐impacted sites.
- 1 March 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (2) , 9-18
Advances in Remediation: Lightning in a Bottle—Electrochemical Oxidation and Plasma for PFAS Destruction
- 1 March 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (2) , 9-18
Advances in Remediation: Lightning in a Bottle—Electrochemical Oxidation and Plasma for PFAS Destruction
- 21 January 2026
- Published by MyJove Corporation
- No. 227,p. e69443
JoVE Video Dataset
Subsurface chemical, geochemical, and microbiological interactions, such as reactive mineral formation, gas generation, and contaminant sorption, play a critical role in shaping remediation strategies. However, evaluating these processes at the field scale is often limited by the expense and invasiveness of traditional sampling methods. The mineral trap sampler offers a practical, low-cost alternative for in situ monitoring of reactive mineral formation without requiring additional drilling or core extraction. Deployed within the screen interval of a monitoring well, the sampler passively collects mineral precipitates and microbial biomass over a period of at least thirty days. Once retrieved, the sampler is vacuum sealed and transported on ice to a laboratory for analysis using standard commercial techniques. This innovation enables scientists and engineers to assess both the rate and spatial distribution of mineral precipitation, providing valuable insights into subsurface conditions. By delivering actionable data on mineral formation and microbial activity, the mineral trap sampler supports performance evaluations and helps guide optimization strategies for remediation systems. Its simplicity and affordability make it a useful tool for improving site characterization and long-term management.
- 21 January 2026
- Published by MyJove Corporation
- No. 227,p. e69443
JoVE Video Dataset
Subsurface chemical, geochemical, and microbiological interactions, such as reactive mineral formation, gas generation, and contaminant sorption, play a critical role in shaping remediation strategies. However, evaluating these processes at the field scale is often limited by the expense and invasiveness of traditional sampling methods. The mineral trap sampler offers a practical, low-cost alternative for in situ monitoring of reactive mineral formation without requiring additional drilling or core extraction. Deployed within the screen interval of a monitoring well, the sampler passively collects mineral precipitates and microbial biomass over a period of at least thirty days. Once retrieved, the sampler is vacuum sealed and transported on ice to a laboratory for analysis using standard commercial techniques. This innovation enables scientists and engineers to assess both the rate and spatial distribution of mineral precipitation, providing valuable insights into subsurface conditions. By delivering actionable data on mineral formation and microbial activity, the mineral trap sampler supports performance evaluations and helps guide optimization strategies for remediation systems. Its simplicity and affordability make it a useful tool for improving site characterization and long-term management.
- 20 January 2026
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 227,p. e69443
Deployment and Retrieval of Mineral Samplers
Subsurface chemical, geochemical, and microbiological interactions, such as reactive mineral formation, gas generation, and contaminant sorption, play a critical role in shaping remediation strategies. However, evaluating these processes at the field scale is often limited by the expense and invasiveness of traditional sampling methods. The mineral trap sampler offers a practical, low-cost alternative for in situ monitoring of reactive mineral formation without requiring additional drilling or core extraction. Deployed within the screen interval of a monitoring well, the sampler passively collects mineral precipitates and microbial biomass over a period of at least thirty days. Once retrieved, the sampler is vacuum sealed and transported on ice to a laboratory for analysis using standard commercial techniques. This innovation enables scientists and engineers to assess both the rate and spatial distribution of mineral precipitation, providing valuable insights into subsurface conditions. By delivering actionable data on mineral formation and microbial activity, the mineral trap sampler supports performance evaluations and helps guide optimization strategies for remediation systems. Its simplicity and affordability make it a useful tool for improving site characterization and long-term management.
- 20 January 2026
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 227,p. e69443
Deployment and Retrieval of Mineral Samplers
Subsurface chemical, geochemical, and microbiological interactions, such as reactive mineral formation, gas generation, and contaminant sorption, play a critical role in shaping remediation strategies. However, evaluating these processes at the field scale is often limited by the expense and invasiveness of traditional sampling methods. The mineral trap sampler offers a practical, low-cost alternative for in situ monitoring of reactive mineral formation without requiring additional drilling or core extraction. Deployed within the screen interval of a monitoring well, the sampler passively collects mineral precipitates and microbial biomass over a period of at least thirty days. Once retrieved, the sampler is vacuum sealed and transported on ice to a laboratory for analysis using standard commercial techniques. This innovation enables scientists and engineers to assess both the rate and spatial distribution of mineral precipitation, providing valuable insights into subsurface conditions. By delivering actionable data on mineral formation and microbial activity, the mineral trap sampler supports performance evaluations and helps guide optimization strategies for remediation systems. Its simplicity and affordability make it a useful tool for improving site characterization and long-term management.
- Open Access
- 19 January 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (2) , 44-54
Effect of Moderate Heat on TCE Reductive Dechlorination Rates in Groundwater
Low‐temperature heating (in the mesophilic range of ~15 to 40 °C) of contaminated aquifers offers the prospect of increasing the rates for biotic and abiotic treatment of volatile organic compounds. Thermal In Situ Sustainable Remediation (TISR®) is one of the approaches available to implement low temperature heating. The effectiveness of implementing TISR depends in part on the magnitude of increase in bioremediation in response to heating. The objective of this study was to evaluate the effect of temperature on the kinetics of trichloroethene (TCE) dechlorination. Samples of groundwater and soil were collected from a site in southern California that has been undergoing treatment of a plume of TCE and other chlorinated volatile organic compounds (VOCs) using biostimulation and where a field test of TISR is being conducted. Microcosms were prepared in an anaerobic chamber with ~92 g of wet sediment and ~93 mL of groundwater with ~5.4 mg/L of TCE. Treatments included unamended and lactate‐amended microcosms, incubated at 18, 25, 30, 35, 40, and 50 °C. For the unamended microcosms, activity was limited to TCE reduction to cis ‐1,2‐dichloroethene (cDCE), indicating that at the time and location of sample collection, the aquifer was electron donor limited. The first‐order rate of TCE reduction to cDCE increased by approximately 6‐fold from 0.078 d −1 at 18 °C to 0.48 d −1 at 25 °C, and then declined to less than 0.11 d −1 at temperatures of 30 °C and above. For the lactate‐amended treatment, complete dechlorination of TCE to ethene occurred. First‐order dechlorination rate constants were determined based on a chloride mass balance. The rate constants increased approximately 2.5‐fold from 0.12 d −1 at 18 °C to 0.30 d −1 at 25 °C, and 3.8‐fold from 18 °C to 0.46 d −1 at 35 °C. No dechlorination occurred at 40 or 50 °C. Molecular analysis of the lactate‐amended microcosms confirmed the presence of microbes capable of TCE reduction to cDCE (e.g., Desulfitobacterium and Dehalobacter ) and complete reduction of TCE to ethene ( Dehalococcoides and Dehalogenimonas ), as well as the genes for key dehalogenases (PCE Reductase, tceA Reductase, and Vinyl Chloride Reductase). These results confirm the potential for significant improvements to the rate of complete biotic reductive dechlorination of TCE in response to moderate heating and biostimulation of an aquifer.
- 19 January 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (2) , 44-54
Open AccessEffect of Moderate Heat on TCE Reductive Dechlorination Rates in Groundwater
Low‐temperature heating (in the mesophilic range of ~15 to 40 °C) of contaminated aquifers offers the prospect of increasing the rates for biotic and abiotic treatment of volatile organic compounds. Thermal In Situ Sustainable Remediation (TISR®) is one of the approaches available to implement low temperature heating. The effectiveness of implementing TISR depends in part on the magnitude of increase in bioremediation in response to heating. The objective of this study was to evaluate the effect of temperature on the kinetics of trichloroethene (TCE) dechlorination. Samples of groundwater and soil were collected from a site in southern California that has been undergoing treatment of a plume of TCE and other chlorinated volatile organic compounds (VOCs) using biostimulation and where a field test of TISR is being conducted. Microcosms were prepared in an anaerobic chamber with ~92 g of wet sediment and ~93 mL of groundwater with ~5.4 mg/L of TCE. Treatments included unamended and lactate‐amended microcosms, incubated at 18, 25, 30, 35, 40, and 50 °C. For the unamended microcosms, activity was limited to TCE reduction to cis ‐1,2‐dichloroethene (cDCE), indicating that at the time and location of sample collection, the aquifer was electron donor limited. The first‐order rate of TCE reduction to cDCE increased by approximately 6‐fold from 0.078 d −1 at 18 °C to 0.48 d −1 at 25 °C, and then declined to less than 0.11 d −1 at temperatures of 30 °C and above. For the lactate‐amended treatment, complete dechlorination of TCE to ethene occurred. First‐order dechlorination rate constants were determined based on a chloride mass balance. The rate constants increased approximately 2.5‐fold from 0.12 d −1 at 18 °C to 0.30 d −1 at 25 °C, and 3.8‐fold from 18 °C to 0.46 d −1 at 35 °C. No dechlorination occurred at 40 or 50 °C. Molecular analysis of the lactate‐amended microcosms confirmed the presence of microbes capable of TCE reduction to cDCE (e.g., Desulfitobacterium and Dehalobacter ) and complete reduction of TCE to ethene ( Dehalococcoides and Dehalogenimonas ), as well as the genes for key dehalogenases (PCE Reductase, tceA Reductase, and Vinyl Chloride Reductase). These results confirm the potential for significant improvements to the rate of complete biotic reductive dechlorination of TCE in response to moderate heating and biostimulation of an aquifer.
- 1 January 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (1) , 10-20
Advances in Remediation: PFAS Precursors—Dark Matter Menace or Negligible Nothingburger?
- 1 January 2026
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 46 (1) , 10-20
Advances in Remediation: PFAS Precursors—Dark Matter Menace or Negligible Nothingburger?
- Open Access
Monitoring Groundwater Thermal Treatment Using a Fiber-Optic Distributed Temperature Sensing Network
Groundwater contaminated with organic chemicals can be treated by raising the subsurface temperature, thereby enhancing the rate of microbial degradation. This process requires careful monitoring through space and time to ensure that heat is being delivered to the most contaminated regions of the groundwater system. Here, we demonstrate the effectiveness of a fiber-optic distributed temperature sensing (DTS) system as a high spatial and temporal resolution monitoring strategy. The DTS sensing system required the installation of fiber optic cable in the subsurface. Boreholes were drilled with hollow casings, a fiber optic cable was inserted into the casings, and then, the casings were withdrawn to allow the formation to collapse around the fiber. The fiber was then fusion-spliced into a single continuous fiber that could be interrogated by a Raman-based DTS unit. Temperature measurements were collected at 30 min intervals over a 575 m span with 0.25 m spatial sampling, resulting in over 110,000 temperature data points per day. With this high resolution monitoring the development of thermal plumes emanating from solar-heated borehole heat exchangers could be closely monitored. The pseudo-3D monitoring network showed the lateral and upward migration of the induced thermal plumes over time. This information was valuable for assuring the heated groundwater was contacting the intended treatment zone.
Open AccessMonitoring Groundwater Thermal Treatment Using a Fiber-Optic Distributed Temperature Sensing Network
Groundwater contaminated with organic chemicals can be treated by raising the subsurface temperature, thereby enhancing the rate of microbial degradation. This process requires careful monitoring through space and time to ensure that heat is being delivered to the most contaminated regions of the groundwater system. Here, we demonstrate the effectiveness of a fiber-optic distributed temperature sensing (DTS) system as a high spatial and temporal resolution monitoring strategy. The DTS sensing system required the installation of fiber optic cable in the subsurface. Boreholes were drilled with hollow casings, a fiber optic cable was inserted into the casings, and then, the casings were withdrawn to allow the formation to collapse around the fiber. The fiber was then fusion-spliced into a single continuous fiber that could be interrogated by a Raman-based DTS unit. Temperature measurements were collected at 30 min intervals over a 575 m span with 0.25 m spatial sampling, resulting in over 110,000 temperature data points per day. With this high resolution monitoring the development of thermal plumes emanating from solar-heated borehole heat exchangers could be closely monitored. The pseudo-3D monitoring network showed the lateral and upward migration of the induced thermal plumes over time. This information was valuable for assuring the heated groundwater was contacting the intended treatment zone.