Christian Reese
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christian Reese has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Katharina Schmitz
RWTH Aachen University
3 shared publications - Abdulaziz Hanifa
Institute for Fluid Power Drives and Systems (IFAS), RWTH Aachen University, 52074 Aachen, Germany
2 shared publications - Daniel Pak
Universität Siegen Lehrstuhl für Stahlbau und Stahlverbundbau Paul‐Bonatz‐Str. 9–11 57076 Siegen
2 shared publications - Faras Brumand-Poor
RWTH Aachen University, Institute for Fluid Power Drives and Systems (ifas), Aachen, Germany
2 shared publications Katharina Schmitz
Institute for Fluid Power Drives and Systems (ifas), RWTH Aachen University, Campus-Boulevard 30, D-52074 Aachen, Germany
2 shared publications- Katharina Schmitz
Institute for Fluid Power Drives and Systems (IFAS), RWTH Aachen University, 52074 Aachen, Germany
2 shared publications
Latest Publications
- Open Access
- 16 September 2025
- Published by University of Maribor
- p. 131-146
Implementation and Experimental Validation of a Time-Controlled Quick-Exhaust for Downstream Throttled Pneumatic Drives
Downstream-throttled pneumatic cylinders are frequently utilized as actuators for motion tasks due to their cost-effectiveness, durability, and robustness. However, they are often regarded as energy-inefficient. This paper presents a novel approach to enhance efficiency by focusing solely on controlling the exhaust air. The proposed system utilizes a time-controlled pneumatic-mechanical quick-exhaust valve, which allows high acceleration at the start of the stroke and subsequent deceleration via conventional downstream throttling. Building on a previous lumped-parameter simulation study, this work details the technical implementation of the concept and provides experimental results that assess its performance and robustness. Comparative tests with a conventional downstream-throttled system demonstrate that the cylinder can be downsized by at least one size, thereby substantially reducing air consumption. However, this improvement comes at the cost of reduced robustness, which necessitates further investigation. The paper covers the entire development process from the initial concept, over the component design, robustness studies and improvements up to a final experimental validation of its dynamic behaviour and compressed air savings in direct comparison to a conventional downstream-throttled drive.
- 16 September 2025
- Published by University of Maribor
- p. 131-146
Open AccessImplementation and Experimental Validation of a Time-Controlled Quick-Exhaust for Downstream Throttled Pneumatic Drives
Downstream-throttled pneumatic cylinders are frequently utilized as actuators for motion tasks due to their cost-effectiveness, durability, and robustness. However, they are often regarded as energy-inefficient. This paper presents a novel approach to enhance efficiency by focusing solely on controlling the exhaust air. The proposed system utilizes a time-controlled pneumatic-mechanical quick-exhaust valve, which allows high acceleration at the start of the stroke and subsequent deceleration via conventional downstream throttling. Building on a previous lumped-parameter simulation study, this work details the technical implementation of the concept and provides experimental results that assess its performance and robustness. Comparative tests with a conventional downstream-throttled system demonstrate that the cylinder can be downsized by at least one size, thereby substantially reducing air consumption. However, this improvement comes at the cost of reduced robustness, which necessitates further investigation. The paper covers the entire development process from the initial concept, over the component design, robustness studies and improvements up to a final experimental validation of its dynamic behaviour and compressed air savings in direct comparison to a conventional downstream-throttled drive.
- Open Access
- 4 March 2025
- Published by MDPI AG in Journal of Experimental and Theoretical Analyses
- Vol. 3 (1) , 8
Advancing Pressure-Based Flow Rate Soft Sensors: Signal Filtering Effects and Non-Laminar Flow Rate Determination
Precise flow measurement is crucial in fluid power systems. Especially in combination with pressure, hydraulic power can be particularly beneficial for predictive maintenance and control applications. However, conventional flow sensors in fluid power systems are often invasive, thus disrupting the flow and yielding unreliable measurements, especially under transient conditions. A common alternative is to estimate the flow rate using pressure differentials along a pipe and the Hagen–Poiseuille law, which is limited to steady, laminar, and incompressible flows. This study advances a previously introduced analytical soft sensor, demonstrating its ability to accurately determine the transient pipe flow beyond laminar conditions, without requiring a dedicated flow rate sensor. This method provides a robust and computationally efficient solution for real-world hydraulic systems by applying two pressure transducers. A key contribution of this work is the investigation of signal filtering, revealing that even a simple first-order low-pass filter with a 100 Hz cutoff frequency significantly improves accuracy, which is demonstrated for pulsation frequencies of 5, 10, and 15 Hz, where the filtered results closely match experimental data from a test rig. These findings underscore the soft sensor’s potential as a reliable alternative to traditional flow sensors, offering high accuracy with minimal computational overhead for a wide range of flow conditions.
- 4 March 2025
- Published by MDPI AG in Journal of Experimental and Theoretical Analyses
- Vol. 3 (1) , 8
Open AccessAdvancing Pressure-Based Flow Rate Soft Sensors: Signal Filtering Effects and Non-Laminar Flow Rate Determination
Precise flow measurement is crucial in fluid power systems. Especially in combination with pressure, hydraulic power can be particularly beneficial for predictive maintenance and control applications. However, conventional flow sensors in fluid power systems are often invasive, thus disrupting the flow and yielding unreliable measurements, especially under transient conditions. A common alternative is to estimate the flow rate using pressure differentials along a pipe and the Hagen–Poiseuille law, which is limited to steady, laminar, and incompressible flows. This study advances a previously introduced analytical soft sensor, demonstrating its ability to accurately determine the transient pipe flow beyond laminar conditions, without requiring a dedicated flow rate sensor. This method provides a robust and computationally efficient solution for real-world hydraulic systems by applying two pressure transducers. A key contribution of this work is the investigation of signal filtering, revealing that even a simple first-order low-pass filter with a 100 Hz cutoff frequency significantly improves accuracy, which is demonstrated for pulsation frequencies of 5, 10, and 15 Hz, where the filtered results closely match experimental data from a test rig. These findings underscore the soft sensor’s potential as a reliable alternative to traditional flow sensors, offering high accuracy with minimal computational overhead for a wide range of flow conditions.
- Open Access
- 7 January 2025
- Published by MDPI AG in Preprints.org
Advancing Pressure-Based Flow Rate Soft Sensors: Signal Filtering Effects and Non-Laminar Flow Rate Determination
Precise flow measurement is pivotal in hydraulic systems, serving as an essential parameter for fluid power control. When combined with pressure data, it also facilitates calculating hydraulic power, proving invaluable for applications like predictive maintenance. Conventional flow sensors in fluid power systems are typically invasive, often disrupting the flow and delivering unreliable measurements, particularly during transient conditions. One common approach relies on determining the flow rate by measuring the pressure difference along a pipe and applying the Hagen-Poiseuille law, constrained to steady, laminar, and incompressible flows. This study presents the capability of a previously introduced analytical soft sensor to determine transient pipe flow for non-laminar flow rates. This method does not require a flow rate sensor and utilizes two pressure transducers to determine the pipe flow. Furthermore, the relevance of filtering is investigated, and the robustness of the soft sensor is demonstrated by the outcome that even basic filtering results in a good match between the soft sensor and test rig. The findings underscore the soft sensor’s capability to deliver accurate and computationally efficient measurements of transient volumetric flow based solely on pressure data for laminar and non-laminar flow with simple filtering of real-world signals.
- 7 January 2025
- Published by MDPI AG in Preprints.org
Open AccessAdvancing Pressure-Based Flow Rate Soft Sensors: Signal Filtering Effects and Non-Laminar Flow Rate Determination
Precise flow measurement is pivotal in hydraulic systems, serving as an essential parameter for fluid power control. When combined with pressure data, it also facilitates calculating hydraulic power, proving invaluable for applications like predictive maintenance. Conventional flow sensors in fluid power systems are typically invasive, often disrupting the flow and delivering unreliable measurements, particularly during transient conditions. One common approach relies on determining the flow rate by measuring the pressure difference along a pipe and applying the Hagen-Poiseuille law, constrained to steady, laminar, and incompressible flows. This study presents the capability of a previously introduced analytical soft sensor to determine transient pipe flow for non-laminar flow rates. This method does not require a flow rate sensor and utilizes two pressure transducers to determine the pipe flow. Furthermore, the relevance of filtering is investigated, and the robustness of the soft sensor is demonstrated by the outcome that even basic filtering results in a good match between the soft sensor and test rig. The findings underscore the soft sensor’s capability to deliver accurate and computationally efficient measurements of transient volumetric flow based solely on pressure data for laminar and non-laminar flow with simple filtering of real-world signals.
- Open Access
- 4 July 2024
- Published by River Publishers in International Journal of Fluid Power
- Vol. 25 (1) , 1-26
Comprehensive Study of Energy-Saving Strategies Through Combined Throttling
In the field of pneumatic automation, downstream throttled pneumatic drives are widely adopted for motion tasks, valued for their cost-effectiveness, durability, and high-power density. However, this switching scheme is often regarded as being inefficient. Consequently, many researchers have focused on developing more efficient control strategies. In this paper a novel combined throttling scheme aimed at reducing air consumption is investigated. The paper offers a comprehensive overview of the design methodology and simulative analysis. A subsequent prototypical realization demonstrates the feasibility and function of the novel system with two distinct shut-off variants. In this way, the theoretical design methodology was validated by experimental results. The presented compressed air savings are adjusted to changes in cycle time, providing an objective evaluation in comparison to state-of-the-art system. The findings show a significant reduction in normalized air consumption with the novel circuit for selected load cases. The main characteristics and potential of the combined throttling approach are highlighted, thus facilitating the assessment of its viability in practical applications through a deeper understanding of the system.
- 4 July 2024
- Published by River Publishers in International Journal of Fluid Power
- Vol. 25 (1) , 1-26
Open AccessComprehensive Study of Energy-Saving Strategies Through Combined Throttling
In the field of pneumatic automation, downstream throttled pneumatic drives are widely adopted for motion tasks, valued for their cost-effectiveness, durability, and high-power density. However, this switching scheme is often regarded as being inefficient. Consequently, many researchers have focused on developing more efficient control strategies. In this paper a novel combined throttling scheme aimed at reducing air consumption is investigated. The paper offers a comprehensive overview of the design methodology and simulative analysis. A subsequent prototypical realization demonstrates the feasibility and function of the novel system with two distinct shut-off variants. In this way, the theoretical design methodology was validated by experimental results. The presented compressed air savings are adjusted to changes in cycle time, providing an objective evaluation in comparison to state-of-the-art system. The findings show a significant reduction in normalized air consumption with the novel circuit for selected load cases. The main characteristics and potential of the combined throttling approach are highlighted, thus facilitating the assessment of its viability in practical applications through a deeper understanding of the system.
- Open Access
- 1 January 2024
- Published by River Publishers
- p. 599-611
FEASIBILITY STUDY AND EXPERIMENTAL VALIDATION OF A NOVEL COMBINED THROTTLING APPROACH
In the field of pneumatic automation, downstream throttled pneumatic drives are commonly used for motion tasks due to their cost-effectiveness, durability, and robustness. However, this type of system is often regarded as being inefficient. Consequently, many researchers have focused on developing more efficient control strategies. This paper presents the results of an experimental investigation of three distinct pneumatic circuits: a novel combined throttling approach, the control by a commercially available downstream throttle with quick exhaust function and conventional downstream throttling. A metric for comparing energy savings adjusted to changes in cycle time is introduced for objective evaluation. The findings highlight a significant reduction in normalized air consumption with the novel circuit compared to both state of the art control schemes.
- 1 January 2024
- Published by River Publishers
- p. 599-611
Open AccessFEASIBILITY STUDY AND EXPERIMENTAL VALIDATION OF A NOVEL COMBINED THROTTLING APPROACH
In the field of pneumatic automation, downstream throttled pneumatic drives are commonly used for motion tasks due to their cost-effectiveness, durability, and robustness. However, this type of system is often regarded as being inefficient. Consequently, many researchers have focused on developing more efficient control strategies. This paper presents the results of an experimental investigation of three distinct pneumatic circuits: a novel combined throttling approach, the control by a commercially available downstream throttle with quick exhaust function and conventional downstream throttling. A metric for comparing energy savings adjusted to changes in cycle time is introduced for objective evaluation. The findings highlight a significant reduction in normalized air consumption with the novel circuit compared to both state of the art control schemes.