    Mechanical testing of transtibial prosthetic sockets: A discussion paper from the American Orthotic and Prosthetic Association Socket Guidance Workgroup

    by Francesca Meng Gariboldi, Andrea Giovanni MEng Cutti, Stefania Bpo(Hons) Fatone, Eric Nickel, Alex Meng Dickinson, Joshua Beng Steer, Jeffrey Cpo Erenstone, Saeed PhD Zahedi, Aopa Socket Guidance Workgroup, Gary Ms Collaborators Berke, et al.

    Background: The advent of novel manufacturing technologies, materials, and socket design concepts could introduce risks to prosthetic limb users, as the existing knowledge base for safe fabrication may not apply. Moreover, although structural test standards exist for mass-produced prosthetic components, they are not applicable to prosthetic sockets. Methods: The “AOPA Socket Guidance Workgroup” was formed in 2020 to provide the prosthetic community with evidence-based clinical best practices and methods in the field of prosthetic socket structural analysis. This multidisciplinary expert workgroup undertook a critical analysis of the knowledge gaps regarding the requirements for mechanical testing of lower limb prosthetic sockets. Results: The Workgroup identified knowledge gaps in 4 domains. Domain 1 describes the shape and composition of a mock residual limb, required to support and generate in vivo representative loading within the socket. Domain 2 concerns prosthetic socket coordinate systems and alignment. Domain 3 regards the components and requirements of test specimens. Finally, Domain 4 considers test conditions, loading parameters, and acceptance criteria. Conclusions: This paper describes these knowledge gaps in detail and recommends potential solution approaches based on literature review, group consensus around existing knowledge, or the formation of new study groups to fill each knowledge gap. Our intent is for the recommendations arising from this paper to support the community (e.g., researchers in the clinic, academia, industry, and funders) in addressing these knowledge gaps.


  • Toward standardized methods for prosthetic socket mechanical testing

    by Alex Dickinson, Eric Nickel, Stefania Fatone, Francesca Gariboldi, Joshua Steer, Andrea Giovanni Cutti, Jeffrey Erenstone, Saeed Zahedi, Aopa Socket Guidance Workgroup


  • Design refinement and evaluation of a mobile manual standing wheelchair

    by Gary Goldish, Gregory Voss, Steve Morin, Billie Slater, Dan Johnson, Stuart Fairhurst, Eric Nickel, Crystal Stien, Patricia McCracken, Kristin Hanowski, et al.

    There are no manually propelled wheelchairs on the market that are mobile in both seated and standing positions. In response to this product gap, our group formerly designed a mobile manual standing wheelchair (MMSW) and gathered stakeholder feedback. The purpose of this study was to refine the MMSW based on feedback, including weight and width reduction, and evaluate its performance. The MMSW was subjected to ANSI/RESNA stability testing, and three male participants completed a subset of the wheelchair skills test, including a 100-m roll test in the MMSW (seated and standing) and in their ultralight wheelchair. The MMSW met ANSI/RESNA stability safety standards. During the 100-m roll test, participants reached speeds with the MMSW in both the standing and sitting postures similar or greater than those typical of moving in the home environment (1.11 m/s seated; 0.79 m/s standing). Mobility speeds in the MMSW in the standing position were about three times faster than average walking speeds in exoskeletons (0.26 m/s exoskeletons). With the addition of chain drive bracing to the MMSW, one user was able to reach speeds in the standing position similar to average neurotypical walking speeds indicating the possibility for wheelchair users to be able to move in pace with family and friends. All participants expressed interest in the MMSW to facilitate improved quality of life. Further work is needed to test the utility of the MMSW in home and community settings, and its potential effects on standing time and health outcomes.


  • Pilot Test of a Definitive Prosthetic Socket Made with 3D Printing Technology

    by Eric Nickel, Alana Bs Cataldo, Nicole Cpo Walker, Christine Bs Santa Ana, Kyle Cpo Barrons, Amy Ma Gravely, Barry Bs Hand, Andrew Hansen

    Introduction: Additive manufacturing (also known as 3D printing) as a fabrication method is ideally suited to merging the organic shapes of human anatomy with engineered components. Many early adopters are exploring the application of these technologies for the fabrication of 3D-printed sockets, but questions remain regarding the ability to fabricate strong, well-fitting definitive sockets. The goal of the present study was to examine the real-world effect of using 3D-printed sockets with regards to mobility, comfort, balance confidence, and user acceptance. Materials and Methods: Nine veterans with transtibial amputations participated in the study, three each using pin, sealing sleeve, or seal-in liner for suspension. Participants had their conventional definitive socket duplicated using 3D printing. When the 3D-printed socket was ready, using their conventional socket, participants performed a 2-minute walk test, followed by socket comfort score and rating of perceived exertion (10-point scale), Prosthetic Limb Users Survey of Mobility, Activities-Specific Balance Confidence, select subscales of the Prosthesis Evaluation Questionnaire, and the Amputee Body Image Scale–Revised. After completing the baseline data, participants were fitted with the 3D-printed socket and, after using it for 2 weeks, we repeated the data collection. Results: Three participants were not able to complete the study. No large differences were observed for any of the measures. Participants were generally satisfied with the fit of the 3D-printed sockets, but there were challenges with getting the 3D-printed sockets to support elevated vacuum with the sealing sleeve and seal-in liner suspension methods. Conclusions: No differences in performance or user acceptance were identified for pin suspension, but the 3D-printed sockets were not able to reliably support suction or elevated vacuum; further development will be needed before they are ready for clinical application. Clinical Relevance: The present study has demonstrated the ability to achieve satisfactory fit and outcomes using 3D printing to fabricate definitive prosthetic sockets, but the printing method was unable to deliver consistent air-tight sealing for suction or elevated vacuum suspension. Other 3D printing methods and some secondary processing steps may be able to correct this deficiency.


  • Biomechanical characterization of the foot-ground interaction among Service members with unilateral transtibial limb loss performing unconstrained drop-landings: Effects of drop height and added mass

    by Jonathan M. Elrod, Barri L. Schnall, Timothy C. Mauntel, Nora L. Watson, Sara R. Koehler-McNicholas, Eric A. Nickel, Andrew H. Hansen, Christopher L. Dearth, Brad D. Hendershot

  • Three-dimensional printing in prosthetics: Method for managing rapid limb volume change

    by Eric Nickel, Kyle Barrons, Barry Hand, Alana Cataldo, Andrew Hansen

    Background and Aim: During post-amputation recovery or rapid body mass change, residual limb volume can change quickly, requiring frequent adjustments or replacement of the socket to maintain fit. The aim of this pilot test was to evaluate the feasibility of using a three-dimensional-printed insert to extend the service life of a prosthetic socket after substantial residual limb volume loss. Technique: One research subject with a well-fitting transtibial prosthetic socket had an oversized socket fabricated to simulate substantial limb volume loss. The digital shapes of the oversized and well-fitting sockets were used to create a three-dimensional-printed insert to restore fit. Discussion: Two-minute walk test distance decreased when using the oversized socket without the insert, but not when using the socket with the insert. Socket comfort score was 8+ under all conditions. These results suggest that three-dimensional-printed inserts may be an effective method of extending the service life of prosthetic sockets when rapid limb volume loss occurs.


  • Open Access

    Improving Automatic Control of an Ankle-Foot Prosthesis Using Machine Learning Algorithms

    by Stuart R. Fairhurst, Sara R. Koehler-McNicholas, Billie C. S. Slater, Eric A. Nickel, Karl A. Koester, Gregory O. Voss, Andrew H. Hansen, John E. Ferguson

    Most commercially available lower-limb prostheses are designed for walking, not for standing. The Minneapolis VA Health Care System has developed a bimodal prosthetic ankle-foot system with distinct modes for walking and standing [1]. With this device, a prosthesis user can select standing or walking mode in order to maximize standing stability or walking functionality, depending on the activity and context. Additionally, the prosthesis was designed to allow for an “automatic mode” to switch between standing and walking modes based on readings from an onboard Inertial Measurement Unit (IMU) without requiring user interaction to manually switch modes. A smartphone app was also developed to facilitate changing between walking, standing and automatic modes. The prosthesis described in [1] was used in a pilot study with 18 Veterans with lower-limb amputations to test static, dynamic, and functional postural stability. As part of the study, 17 Veterans were asked for qualitative feedback on the bimodal ankle-foot system (Table 1). The majority of participants (82%) expressed an interest in having an automatic mode. The participants also indicated that the automatic mode would need to reach walking mode on their first step and to lock the ankle quickly once the standing position was achieved. When asked about how they wanted to control the modes of the prosthesis, 82% wanted to use a physical switch and only 12% wanted to use a smartphone app. The results indicated that the following major design changes would be needed: 1) A fast and accurate automatic mode 2) A physical switch for mode changes This paper describes the use of machine learning algorithms to create an improved automatic mode and the use of stakeholder feedback to design a physical switch for the bimodal ankle-foot system.


  • Development of a Bimodal Ankle-Foot Prosthesis for Walking and Standing/Swaying

    by Andrew H. Hansen, Eric A. Nickel

    The human ankle-foot system conforms to a circular effective rocker shape for walking, but to a much flatter effective shape for standing and swaying. Many persons with lower limb amputations have impaired balance and reduced balance confidence, and may benefit from prostheses designed to provide flatter effective rocker shapes during standing and swaying tasks. This paper describes the development and testing of an ankle-foot prosthesis prototype that provides distinctly different mechanical properties for walking and standing/swaying. The prototype developed was a single-axis prosthetic foot with a lockable ankle for added stability during standing and swaying. The bimodal ankle-foot prosthesis prototype was tested on pseudoprostheses (walking boots with prosthetic feet beneath) for walking and standing/swaying loads, and was compared to an Otto Bock single-axis prosthetic foot and to able-bodied data collected in a previous study. The height-normalized radius of the effective rocker shape for walking with the bimodal ankle-foot prototype was equal to that found earlier for able-bodied persons (0.17); the standing and swaying effective shape had a lower height-normalized radius (0.70) compared with that previously found for able-bodied persons (1.11). The bimodal ankle-foot prosthesis prototype had a similar radius as the Otto Bock single-axis prosthetic foot for the effective rocker shape for walking (0.17 for both), but had a much larger radius for standing and swaying (0.70 for bimodal, 0.34 for single-axis). The results suggest that the bimodal ankle-foot prosthesis prototype provides two distinct modes, including a biomimetic effective rocker shape for walking and an inherently stable base for standing and swaying. The radius of the prototype's effective rocker shape for standing/swaying suggests that it may provide inherent mechanical stability to a prosthesis user, since the radius is larger than the typical body center of mass’s distance from the floor (between 50–60% of height). Future testing is warranted to determine if the bimodal ankle-foot prosthesis will increase balance and balance confidence in prosthesis users.


  • Prosthetic Ankle-Foot System That Adapts to Sloped Surfaces

    by Eric A. Nickel, Andrew H. Hansen, Steven A. Gard

    The anatomical ankle is capable of providing adaptation to sloped surfaces, a function that is not available in most traditional lower limb prostheses. Commercial prostheses that are claimed to adapt to slopes are limited by high cost, delay in response, reduced stability, and loss of energy through damping. The purpose of the present work was to develop a prototypical prosthetic ankle unit that adapts to sloped surfaces and is sufficiently durable for short-term take-home trials. The prototype switches between low and high rotational impedances by means of a wrap spring clutch mechanism. The clutch is held in a disengaged position when unloaded and deflection of a compressible pylon under axial load rotates a control collar and engages the clutch. The prototype was subjected to 100,000 cycles of mechanical endurance testing based on ISO 10328 standards to determine the suitability for two-week take-home testing. Three persons with unilateral transtibial amputations were recruited to test the prototype in the laboratory, providing subjective feedback through a survey and participating in a motion analysis study to confirm the performance of the slope adaptation function. Translation of the ankle moment-angle curves for all subjects along the ankle angle axis demonstrated a change of the ankle alignment when subjects walked with the adaptable ankle on surfaces of different slopes. The ankle moment-angle curves had a lower slope than the subjects’ usual prostheses, and some subjects had distinct flat regions in the moment-angle curves when using the adaptable ankle. The arbors of the clutch demonstrated significant wear when tested to 100,000 cycles based on ISO 10328 standards, yet the adaptable ankle continued to hold testing loads. The alignment change observed for sloped surfaces suggests the prototype was providing slope adaptation. The flat regions on the ankle moment-angle curves suggest the clutch may have been slipping. Refinement of the clutch engagement mechanism and continued development to reduce the weight and size of the prototype is needed prior to take-home testing.