CWChristopher D. Wallis

Christopher D. Wallis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christopher D. Wallis has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Air pollution and Alzheimer disease phenotype deplete esterified proresolving lipid mediator reserves in the brain

    by Ameer Y. Taha, Qing Shen, Yurika Otoki, Nuanyi Liang, Kelley T. Patten, Anthony E. Valenzuela, Christopher D. Wallis, Douglas J. Rowland, Abhijit J. Chaudhari, Keith J. Bein, et al.

    BACKGROUND: Traffic-related air pollution (TRAP) is a risk factor for Alzheimer disease (AD), where unresolved brain inflammation has been linked to deficits in the levels of free lipid mediators that enable the resolution of inflammation. It is unknown whether these deficits are due to reductions in esterified lipid pools, the main source of free bioactive proresolving lipids in the brain, and whether they are related AD pathophysiology. METHODS: This unknown was tested by measuring brain esterified lipid mediators and pathogenic markers of AD in TgF344-AD and WT male and female rats exposed to filtered air or TRAP for 14 months; it was also tested in human postmortem prefrontal cortex of individuals with or without AD. RESULTS: Significant reductions in proresolving lipid mediators esterified to neutral lipids and/or phospholipids were seen in AD and TRAP-exposed female rats, where levels were associated with inflammation, synaptic loss, and impaired glucose metabolism. Lower esterified proresolving lipid mediator concentrations were associated with older age in prefrontal cortex of humans with AD compared with controls. CONCLUSION: Impaired resolution in AD is due to depletion of esterified proresolving lipid pools that supply the brain with free bioactive mediators involved in inflammation resolution. TRAP exposure alters the same esterified resolution pathways, reflecting convergent mechanisms underlying AD.


  • Response from the authors of “Absorption photometry of patterned deposits on IMPROVE PTFE filters”

    by Warren H. White, Scott A. Copeland, Jason Giacomo, Nicole P. Hyslop, Lindsay M. Kline, William Malm, Sean Raffuse, Bret A. Schichtel, Nicholas J. Spada, Christopher D. Wallis, et al.

  • Open Access

    Absorption photometry of patterned deposits on IMPROVE PTFE filters

    by Warren H. White, Scott A. Copeland, Jason Giacomo, Nicole P. Hyslop, Lindsay M. Kline, William Malm, Sean Raffuse, Bret A. Schichtel, Nicholas J. Spada, Christopher D. Wallis, et al.

    The IMPROVE program (Interagency Monitoring of PROtected Visual Environments) tracks long-term trends in the composition and optics of regional haze aerosols in the United States. The absorptance of red (633-nm) light is monitored by filter photometry of 24 h-integrated samples of fine particulate matter (PM 2.5). These are collected every third day at about 150 rural and often remote locations. Systematic reanalyses of archived samples have established the reproducibility of these optical absorption measurements across decades and instrument systems, with a consistent calibration that is traceable back to 2003.IMPROVE samples for nondestructive analyses by photometry, gravimetry, and X-ray fluorescence are all collected on ring-mounted membranes of expanded PTFE (polytetrafluoroethylene). Although attractively inert, low in blank mass, and optically thin, these media yield visibly nonuniform deposits that do not admit direct interpretation according to a naïve "Beer-Lambert" formulation of optical absorption. Most IMPROVE PTFE deposits exhibit a fine-scale "pixelation" shaped by the perforated screen that supports the membrane during sample collection.This paper extends the traditional Beer-Lambert interpretive model to accommodate the patterned deposits generated by IMPROVE and similarly aggressive sampling protocols on PTFE filters. The extended model is then used to assess the bias and epistemic uncertainty in the aerosol absorption coefficient that IMPROVE has historically reported.ImplicationsAmbient fine aerosol particles are widely collected at high sample face velocities on PTFE (Teflon®) membrane filters backed by perforated support screens. The screens' localized blockage of airflow can channel the resulting PM2.5 sample deposits into a pattern of discrete heavily loaded "pixels", where the screen perforations allow flow through the membrane, separated by a lightly loaded background that reflects blockage by the screen. Such non-uniform deposits, collected throughout the United States on FRM filters to monitor NAAQS compliance and on IMPROVE filters to support the Regional Haze Rule, do not meet the requirements of the Beer-Lambert model for optical absorption measurements. This paper extends Beer-Lambert theory to accommodate patterned deposits, and assesses the bias and epistemic uncertainties introduced by historical (mis)reporting based on "Beer's Law". For samples of moderate (and lesser) absorptance, including the bulk of those collected at rural IMPROVE sites to track regional haze, usefully tight bounds are developed for this pixelation bias.


  • Positive and negative emissions from cooling towers, part 2: Particulate matter

    by Christopher D. Wallis, Mason D. Leandro, Patrick Y. Chuang, Anthony S. Wexler

  • Evaluation of passive samplers as a cost-effective method to predict the impact of wildfire smoke in grapes and wines

    by Arran C. Rumbaugh, Chen Liang, Yan Wen, Andrey Khlystov, Dave Campbell, Christopher Wallis, Hao-Lin Fang, Anthony Wexler, Yeongkwon Son


  • Open Access

    UAV-Based Wildland Fire Air Toxics Data Collection and Analysis

    by Prabhash Ragbir, Ajith Kaduwela, David Passovoy, Preet Amin, Shuchen Ye, Christopher Wallis, Christopher Alaimo, Thomas Young, Zhaodan Kong

    Smoke plumes emitted from wildland-urban interface (WUI) wildfires contain toxic chemical substances that are harmful to human health, mainly due to the burning of synthetic components. Accurate measurement of these air toxics is necessary for understanding their impacts on human health. However, air pollution is typically measured using ground-based sensors, manned airplanes, or satellites, which all provide low-resolution data. Unmanned Aerial Vehicles (UAVs) have the potential to provide high-resolution spatial and temporal data due to their ability to hover in specific locations and maneuver with precise trajectories in 3-D space. This study investigates the use of an octocopter UAV, equipped with a customized air quality sensor package and a volatile organic compound (VOC) air sampler, for the purposes of collecting and analyzing air toxics data from wildfire plumes. The UAV prototype developed has been successfully tested during several prescribed fires conducted by the California Department of Forestry and Fire Protection (CAL FIRE). Data from these experiments were analyzed with emphasis on the relationship between the air toxics measured and the different types of vegetation/fuel burnt. BTEX compounds were found to be more abundant for hardwood burning compared to grassland burning, as expected.


  • Positive and negative emissions from cooling towers, part 1: Droplet measurements

    by Mason D. Leandro, Christopher D. Wallis, Anthony S. Wexler, Patrick Y. Chuang

    Wet cooling towers are used in industrial processes, power plants, and heating, ventilation, and air conditioning systems. Their purpose is to reject waste heat from a system through evaporative cooling of process water. Due to their design, a small fraction of process water is emitted from the tower exit, termed “spray drift.” Dissolved solids contained within spray drift droplets are regulated as PM10 emissions by EPA AP-42. Here, we use a novel instrumentation package to measure particulate emissions from drift droplets at two cooling towers located at separate power plants. We find that drift droplet properties depend on the sampling position over the tower so multiple positions need to be sampled to accurately estimate emissions. We estimate 11 and 3.3 grams of PM10 are emitted from each tower per hour, with 78% and 87% of PM10 emissions also qualifying as PM2.5. AP-42 overestimates PM10 emissions by a factor of 2.4 for one tower and nearly 300 for the other. These results suggest that AP-42 may require revision to both accurately reflect lower PM10 emissions and account for unregulated PM2.5, which constitute the majority of emissions. GRAPHICAL ABSTRACT


  • Open Access

    An instrument for direct measurement of emissions: cooling tower example

    by Christopher D. Wallis, Mason D. Leandro, Patrick Y. Chuang, Anthony S. Wexler

    Measuring emissions from stacks is challenging due to accessibility and safety concerns and requires techniques to address a broad range of conditions and measurement challenges. One way to facilitate such measurements is to build an instrument package and then use a crane to hold the package over the emissions source. Here we describe such an instrument package that is used to characterize both wet droplet and dried aerosol emissions from cooling tower spray drift. In this application, the instrument package characterizes the velocity, size distribution, and concentration of the wet droplet emissions and the mass concentration and elemental composition of the dried PM2.5 and PM10 emissions. Subsequent papers will present and analyze the wet and dried emissions from individual towers.


  • Open Access

    Comment on amt-2021-285

    by Christopher D. Wallis, Mason D. Leandro, Patrick Y. Chuang, Anthony S. Wexler

    Measuring emissions from stacks is challenging due to accessibility and safety concerns, and requires techniques to address a broad range of conditions and measurement challenges. One way to facilitate such measurements is to build an instrument package and then use a crane to hold the package over the emissions source. Here we describe such an instrument package that is used to characterize both wet droplet and dried aerosol emissions from cooling tower spray drift. In this application, the instrument package characterizes the velocity, size distribution and concentration of the wet droplet emissions and the mass concentration and elemental composition of the dried PM2.5 and PM10 emissions. Subsequent papers will present and analyze the wet and dried emissions from individual towers.