Guanhui Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guanhui Zhao has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Yaoguang Wang
Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, People's Republic of China
8 shared publications - Yong Zhang
School of Textile Science and Engineering Institute of Flexible Electronics and Intelligent Textile Key Laboratory of Functional Textile Material and Product of the Ministry of Education Xi'an Polytechnic University Xi'an People's Republic of China
7 shared publications Qin Wei
Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China
4 shared publicationsChunfang Cheng
Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China
3 shared publicationsHuixin Wang
Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, China
3 shared publications- Huixin Wang
Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China
3 shared publications
Latest Publications
- 14 July 2024
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 242, 114093
Single-atom nanozymes: Emerging talent for sensitive detection of heavy metals
- 14 July 2024
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 242, 114093
Single-atom nanozymes: Emerging talent for sensitive detection of heavy metals
- Top Cited Papers
- 24 January 2024
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 235, 113767
Advances in the application of metal oxide nanozymes in tumor detection and treatment
- 24 January 2024
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 235, 113767
Top Cited PapersAdvances in the application of metal oxide nanozymes in tumor detection and treatment
- Open Access
- 12 January 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (1) , 40
Advances in the Application of Transition-Metal Composite Nanozymes in the Field of Biomedicine
Due to the limitation that natural peroxidase enzymes can only function in relatively mild environments, nanozymes have expanded the application of enzymology in the biological field by dint of their ability to maintain catalytic oxidative activity in relatively harsh environments. At the same time, the development of new and highly efficient composite nanozymes has been a challenge due to the limitations of monometallic particles in applications and the inherently poor enzyme-mimetic activity of composite nanozymes. The inherent enzyme-mimicking activity is due to Au, Ag, and Pt, along with other transition metals. Moreover, the nanomaterials exhibit excellent enzyme-mimicking activity when composited with other materials. Therefore, this paper focuses on composite nanozymes with simulated peroxidase activity that have been prepared using noble metals such as Au, Ag, and Pt and other transition metal nanoparticles in recent years. Their simulated enzymatic activity is utilized for biomedical applications such as glucose detection, cancer cell detection and tumor treatment, and antibacterial applications.
- 12 January 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (1) , 40
Open AccessAdvances in the Application of Transition-Metal Composite Nanozymes in the Field of Biomedicine
Due to the limitation that natural peroxidase enzymes can only function in relatively mild environments, nanozymes have expanded the application of enzymology in the biological field by dint of their ability to maintain catalytic oxidative activity in relatively harsh environments. At the same time, the development of new and highly efficient composite nanozymes has been a challenge due to the limitations of monometallic particles in applications and the inherently poor enzyme-mimetic activity of composite nanozymes. The inherent enzyme-mimicking activity is due to Au, Ag, and Pt, along with other transition metals. Moreover, the nanomaterials exhibit excellent enzyme-mimicking activity when composited with other materials. Therefore, this paper focuses on composite nanozymes with simulated peroxidase activity that have been prepared using noble metals such as Au, Ag, and Pt and other transition metal nanoparticles in recent years. Their simulated enzymatic activity is utilized for biomedical applications such as glucose detection, cancer cell detection and tumor treatment, and antibacterial applications.
- Open Access
- 19 June 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (6) , 349
MoS2@Au as Label for Sensitive Sandwich-Type Immunoassay of Neuron-Specific Enolase
Neuron-specific enolase (NSE) has gained extensive attention as a reliable target for detecting small cell carcinoma of lungs. In this paper, an electrochemical immunoassay method based on molybdenum disulfide (MoS2) is proposed to detect NSE sensitively. By an in-situ growth method, MoS2 and Au nanoclusters (Au NCs) were composited to form a MoS2@Au nanozyme, and then the secondary antibodies were modified. Primary antibodies were immobilized on amino-reduced graphene oxides to capture NSE. The flower-like MoS2 nanozyme provided abundant sites to load Au NCs and catalyze the decomposition of H2O2, which were beneficial to amplify an amperometric response as well as build up sensitivity. Under optimum conditions, the detection range of this strategy was 0.1 pg·mL−1–10 ng·mL−1 and the limit of detection was 0.05 pg·mL−1. This sensing strategy achieved the prospect of sensitively detecting NSE. Moreover, the prepared electrochemical immunosensor provides a theoretical basis and technical support for the detection of other disease markers.
- 19 June 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (6) , 349
Open AccessMoS2@Au as Label for Sensitive Sandwich-Type Immunoassay of Neuron-Specific Enolase
Neuron-specific enolase (NSE) has gained extensive attention as a reliable target for detecting small cell carcinoma of lungs. In this paper, an electrochemical immunoassay method based on molybdenum disulfide (MoS2) is proposed to detect NSE sensitively. By an in-situ growth method, MoS2 and Au nanoclusters (Au NCs) were composited to form a MoS2@Au nanozyme, and then the secondary antibodies were modified. Primary antibodies were immobilized on amino-reduced graphene oxides to capture NSE. The flower-like MoS2 nanozyme provided abundant sites to load Au NCs and catalyze the decomposition of H2O2, which were beneficial to amplify an amperometric response as well as build up sensitivity. Under optimum conditions, the detection range of this strategy was 0.1 pg·mL−1–10 ng·mL−1 and the limit of detection was 0.05 pg·mL−1. This sensing strategy achieved the prospect of sensitively detecting NSE. Moreover, the prepared electrochemical immunosensor provides a theoretical basis and technical support for the detection of other disease markers.
- Open Access
- 10 March 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 366
Ultrasensitive Photoelectrochemical Immunoassay Strategy Based on Bi2S3/Ag2S for the Detection of the Inflammation Marker Procalcitonin
As an inflammatory marker, procalcitonin (PCT) is more representative than other traditional inflammatory markers. In this work, a highly efficient photoelectrochemical (PEC) immunosensor was constructed based on the photoactive material Bi2S3/Ag2S to realize the sensitive detection of PCT. Bi2S3 was prepared by a hydrothermal method, and Ag2S quantum dots were deposited on the ITO/Bi2S3 surface via in situ reduction. Bi2S3 is a kind of admirable photoelectric semiconductor nanomaterial on account of its moderate bandgap width and low binding rate of photogenerated electron holes, which can effectively convert light energy into electrical energy. Therefore, based on the energy level matching principle of Bi2S3 and Ag2S, a labeled Bi2S3/Ag2S PEC immunosensor was constructed, and the sensitive detection of PCT was successfully established. The linear detection range of the PEC immunosensor was 0.50 pg∙mL−1 to 50 ng∙mL−1, and the minimum detection limit was 0.18 pg∙mL−1. Compared with the traditional PEC strategy, the proposed PEC immunosensor is simple, convenient, and has good anti-interference, sensitivity, and specificity, which could provide a meaningful theoretical basis and reference value for the clinical detection of PCT.
- 10 March 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 366
Open AccessUltrasensitive Photoelectrochemical Immunoassay Strategy Based on Bi2S3/Ag2S for the Detection of the Inflammation Marker Procalcitonin
As an inflammatory marker, procalcitonin (PCT) is more representative than other traditional inflammatory markers. In this work, a highly efficient photoelectrochemical (PEC) immunosensor was constructed based on the photoactive material Bi2S3/Ag2S to realize the sensitive detection of PCT. Bi2S3 was prepared by a hydrothermal method, and Ag2S quantum dots were deposited on the ITO/Bi2S3 surface via in situ reduction. Bi2S3 is a kind of admirable photoelectric semiconductor nanomaterial on account of its moderate bandgap width and low binding rate of photogenerated electron holes, which can effectively convert light energy into electrical energy. Therefore, based on the energy level matching principle of Bi2S3 and Ag2S, a labeled Bi2S3/Ag2S PEC immunosensor was constructed, and the sensitive detection of PCT was successfully established. The linear detection range of the PEC immunosensor was 0.50 pg∙mL−1 to 50 ng∙mL−1, and the minimum detection limit was 0.18 pg∙mL−1. Compared with the traditional PEC strategy, the proposed PEC immunosensor is simple, convenient, and has good anti-interference, sensitivity, and specificity, which could provide a meaningful theoretical basis and reference value for the clinical detection of PCT.
- 1 January 2022
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 606 (Pt 1) , 510-517
Electrochemical aptasensor based on gold modified thiol graphene as sensing platform and gold-palladium modified zirconium metal-organic frameworks nanozyme as signal enhancer for ultrasensitive detection of mercury ions
- 1 January 2022
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 606 (Pt 1) , 510-517
Electrochemical aptasensor based on gold modified thiol graphene as sensing platform and gold-palladium modified zirconium metal-organic frameworks nanozyme as signal enhancer for ultrasensitive detection of mercury ions
- Open Access
- 28 October 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (11) , 421
Ultrasensitive Photochemical Immunosensor Based on Flowerlike SnO2/BiOI/Ag2S Composites for Detection of Procalcitonin
Based on the necessity and urgency of detecting infectious disease marker procalcitonin (PCT), a novel unlabeled photoelectrochemical (PEC) immunosensor was prepared for the rapid and sensitive detection of PCT. Firstly, SnO2 porous nanoflowers with good photocatalytic performance were prepared by combining hydrothermal synthesis and calcining. BiOI nanoflowers were synthesized by facile ultrasonic mixed reaction. Ag2S quantum dots were deposited on SnO2/BiOI composites by in situ growth method. The SnO2/BiOI/Ag2S composites with excellent photoelectric properties were employed as substrate material, which could provide significantly enhanced and stable signal because of the energy level matching of SnO2, BiOI and Ag2S and the good light absorption performance. Accordingly, a PEC immunosensor based on SnO2/BiOI/Ag2S was constructed by using the layered modification method to achieve high sensitivity analysis of PCT. The linear dynamic range of the detection method was 0.50 pg·mL−1~100 ng·mL−1, and the detection limit was 0.14 pg·mL−1. In addition, the designed PEC immunosensor exhibited satisfactory sensitivity, selectivity, stability and repeatability, which opened up a new avenue for the analyzation of PCT and further provided guidance for antibiotic therapy.
- 28 October 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (11) , 421
Open AccessUltrasensitive Photochemical Immunosensor Based on Flowerlike SnO2/BiOI/Ag2S Composites for Detection of Procalcitonin
Based on the necessity and urgency of detecting infectious disease marker procalcitonin (PCT), a novel unlabeled photoelectrochemical (PEC) immunosensor was prepared for the rapid and sensitive detection of PCT. Firstly, SnO2 porous nanoflowers with good photocatalytic performance were prepared by combining hydrothermal synthesis and calcining. BiOI nanoflowers were synthesized by facile ultrasonic mixed reaction. Ag2S quantum dots were deposited on SnO2/BiOI composites by in situ growth method. The SnO2/BiOI/Ag2S composites with excellent photoelectric properties were employed as substrate material, which could provide significantly enhanced and stable signal because of the energy level matching of SnO2, BiOI and Ag2S and the good light absorption performance. Accordingly, a PEC immunosensor based on SnO2/BiOI/Ag2S was constructed by using the layered modification method to achieve high sensitivity analysis of PCT. The linear dynamic range of the detection method was 0.50 pg·mL−1~100 ng·mL−1, and the detection limit was 0.14 pg·mL−1. In addition, the designed PEC immunosensor exhibited satisfactory sensitivity, selectivity, stability and repeatability, which opened up a new avenue for the analyzation of PCT and further provided guidance for antibiotic therapy.