Gabriel J. Abrahams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gabriel J. Abrahams has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Jean-Philippe Tetienne
RMIT University
7 shared publications - Alexander J. Healey
RMIT University
4 shared publications - Harrison Steel
University of Oxford
4 shared publications - Islay O. Robertson
School of Science, RMIT University, Melbourne, Australia
4 shared publications - Sam C. Scholten
Department of Physics School of Science RMIT University Melbourne Australia
4 shared publications - Janet Newman
Collaborative Crystallisation Centre (C3), CSIRO, 343 Royal Parade, Parkville, VIC 3052, Australia
3 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 21 January 2026
- Published by Springer Nature in Nature
- Vol. 649 (8099) , 1172-1179
Quantum spin resonance in engineered proteins for multimodal sensing
Sensing technologies that exploit quantum phenomena for measurement are finding increasing applications across materials, physical and biological sciences 1–7 . Until recently, biological candidates for quantum sensors were limited to in vitro systems, had poor sensitivity and were prone to light-induced degradation. These limitations impeded practical biotechnological applications, and high-throughput study that would facilitate their engineering and optimization. We recently developed a class of magneto-sensitive fluorescent proteins including MagLOV, which overcomes many of these challenges 8 . Here we show that through directed evolution, it is possible to engineer these proteins to alter the properties of their response to magnetic fields and radio frequencies. We find that MagLOV exhibits optically detected magnetic resonance in living bacterial cells at room temperature, at sufficiently high signal-to-noise for single-cell detection. These effects are explained through the radical-pair mechanism, which involves the protein backbone and a bound flavin cofactor. Using optically detected magnetic resonance and fluorescence magnetic-field effects, we explore a range of applications, including spatial localization of fluorescence signals using gradient fields (that is, magnetic resonance imaging using a genetically encoded probe), sensing of the molecular microenvironment, multiplexing of bio-imaging and lock-in detection, mitigating typical biological imaging challenges such as light scattering and autofluorescence. Taken together, our results represent a suite of sensing modalities for engineered biological systems, based on and designed around understanding the quantum-mechanical properties of magneto-sensitive fluorescent proteins.
- 21 January 2026
- Published by Springer Nature in Nature
- Vol. 649 (8099) , 1172-1179
Top Cited PapersOpen AccessQuantum spin resonance in engineered proteins for multimodal sensing
Sensing technologies that exploit quantum phenomena for measurement are finding increasing applications across materials, physical and biological sciences 1–7 . Until recently, biological candidates for quantum sensors were limited to in vitro systems, had poor sensitivity and were prone to light-induced degradation. These limitations impeded practical biotechnological applications, and high-throughput study that would facilitate their engineering and optimization. We recently developed a class of magneto-sensitive fluorescent proteins including MagLOV, which overcomes many of these challenges 8 . Here we show that through directed evolution, it is possible to engineer these proteins to alter the properties of their response to magnetic fields and radio frequencies. We find that MagLOV exhibits optically detected magnetic resonance in living bacterial cells at room temperature, at sufficiently high signal-to-noise for single-cell detection. These effects are explained through the radical-pair mechanism, which involves the protein backbone and a bound flavin cofactor. Using optically detected magnetic resonance and fluorescence magnetic-field effects, we explore a range of applications, including spatial localization of fluorescence signals using gradient fields (that is, magnetic resonance imaging using a genetically encoded probe), sensing of the molecular microenvironment, multiplexing of bio-imaging and lock-in detection, mitigating typical biological imaging challenges such as light scattering and autofluorescence. Taken together, our results represent a suite of sensing modalities for engineered biological systems, based on and designed around understanding the quantum-mechanical properties of magneto-sensitive fluorescent proteins.
- Open Access
Microscopic PhotoSelection (MiPS) of single cells in mother machine microfluidic devices
Techniques for selecting or sorting single cells within large populations of genetic variants are central to synthetic biology and biotechnology. Widely-used methods such as Fluorescence Activated Cell Sorting (FACS) enable rapid processing of large libraries, but are restricted to low-dimensional measurements taken at a single time point. As a result, sorting based on dynamic or multi-trait phenotypes—such as transient properties and properties that occur on fast timescales or in response to dynamic actuating signals—remains fundamentally challenging. Here we introduce Microscopic PhotoSelection (MiPS) which employs an automated robotic platform for single-cell selection based on multiple dynamic criteria, directly on microfluidic mother machine devices. The system couples long-term single-cell imaging with real-time analysis and selective optical targeting, allowing fully automated enrichment using high-intensity UV light or alternative wavelengths with the addition of photosensitisers. By targeting many cells in parallel, our platform overcomes throughput limitations of existing microfluidic-based selection technologies such as optical tweezers or droplet-based methods and provides a direct approach to select cells based on time-resolved, multi-trait phenotypes. We demonstrate the ability to perform in vivo selection and outline how iterative, feedback-based selection strategies can refine enrichment across multiple rounds. Taken together, our work establishes a high-throughput selection framework integrated into microfluidic devices, enabling applications in directed evolution, biosensor optimisation, circuit engineering, and diagnostics, where selection based on dynamic, multi-trait phenotypes is essential.
Open AccessMicroscopic PhotoSelection (MiPS) of single cells in mother machine microfluidic devices
Techniques for selecting or sorting single cells within large populations of genetic variants are central to synthetic biology and biotechnology. Widely-used methods such as Fluorescence Activated Cell Sorting (FACS) enable rapid processing of large libraries, but are restricted to low-dimensional measurements taken at a single time point. As a result, sorting based on dynamic or multi-trait phenotypes—such as transient properties and properties that occur on fast timescales or in response to dynamic actuating signals—remains fundamentally challenging. Here we introduce Microscopic PhotoSelection (MiPS) which employs an automated robotic platform for single-cell selection based on multiple dynamic criteria, directly on microfluidic mother machine devices. The system couples long-term single-cell imaging with real-time analysis and selective optical targeting, allowing fully automated enrichment using high-intensity UV light or alternative wavelengths with the addition of photosensitisers. By targeting many cells in parallel, our platform overcomes throughput limitations of existing microfluidic-based selection technologies such as optical tweezers or droplet-based methods and provides a direct approach to select cells based on time-resolved, multi-trait phenotypes. We demonstrate the ability to perform in vivo selection and outline how iterative, feedback-based selection strategies can refine enrichment across multiple rounds. Taken together, our work establishes a high-throughput selection framework integrated into microfluidic devices, enabling applications in directed evolution, biosensor optimisation, circuit engineering, and diagnostics, where selection based on dynamic, multi-trait phenotypes is essential.
- Open Access
Quantum Spin Resonance in Engineered Magneto-Sensitive Fluorescent Proteins Enables Multi-Modal Sensing in Living Cells
Quantum mechanical phenomena have been identified as fundamentally significant to an increasing number of biological processes. Simultaneously, quantum sensing is emerging as a cutting-edge technology for diverse applications across materials and biological science. However, until recently, biological based candidates for quantum sensors have been limited to in vitro systems, were prone to light induced degradation, and the experimental setups involved are typically not amenable to high-throughput study as would enable further engineering e.g. via directed evolution. We recently created a new class of magneto-sensitive fluorescent proteins (MFPs), which we show overcome these challenges and represent a new form of engineered biological quantum sensors that function both at physiological conditions and in living cells. Through directed evolution, we demonstrate the possibility of engineering these proteins to alter properties of their response to magnetic fields and radio frequencies. These effects are explained in terms of the radical pair mechanism (RPM), involving the protein backbone and a bound flavin cofactor. Using this engineered system we demonstrate the first observation of a fluorescent protein exhibiting Optically Detected Magnetic Resonance (ODMR) in living bacterial cells at room temperature, at sufficiently high signal-to-noise to be detected in a single cell. These magnetic resonance and magnetic field effects measured via fluorescence enable novel technologies; examples we demonstrate include spatial localisation of fluorescence signals using gradient fields (i.e. Magnetic Resonance Imaging (MRI) using a genetically encoded probe), sensing of the molecular microenvironment, multiplexing of bio-imaging, and lock-in detection, overcoming typical fluorescence imaging challenges of light scattering and autofluorescence. Taken together, our results represent a new range of sensing modalities for engineered biological systems, based on and designed around understanding the quantum mechanical properties of MFPs.
Open AccessQuantum Spin Resonance in Engineered Magneto-Sensitive Fluorescent Proteins Enables Multi-Modal Sensing in Living Cells
Quantum mechanical phenomena have been identified as fundamentally significant to an increasing number of biological processes. Simultaneously, quantum sensing is emerging as a cutting-edge technology for diverse applications across materials and biological science. However, until recently, biological based candidates for quantum sensors have been limited to in vitro systems, were prone to light induced degradation, and the experimental setups involved are typically not amenable to high-throughput study as would enable further engineering e.g. via directed evolution. We recently created a new class of magneto-sensitive fluorescent proteins (MFPs), which we show overcome these challenges and represent a new form of engineered biological quantum sensors that function both at physiological conditions and in living cells. Through directed evolution, we demonstrate the possibility of engineering these proteins to alter properties of their response to magnetic fields and radio frequencies. These effects are explained in terms of the radical pair mechanism (RPM), involving the protein backbone and a bound flavin cofactor. Using this engineered system we demonstrate the first observation of a fluorescent protein exhibiting Optically Detected Magnetic Resonance (ODMR) in living bacterial cells at room temperature, at sufficiently high signal-to-noise to be detected in a single cell. These magnetic resonance and magnetic field effects measured via fluorescence enable novel technologies; examples we demonstrate include spatial localisation of fluorescence signals using gradient fields (i.e. Magnetic Resonance Imaging (MRI) using a genetically encoded probe), sensing of the molecular microenvironment, multiplexing of bio-imaging, and lock-in detection, overcoming typical fluorescence imaging challenges of light scattering and autofluorescence. Taken together, our results represent a new range of sensing modalities for engineered biological systems, based on and designed around understanding the quantum mechanical properties of MFPs.
- Open Access
Optimised control of adaptive evolution with competing selective pressures
The development of methods to understand and control the population dynamics of microbial evolution remains an outstanding question in synthetic biology and biotechnology more broadly. Due to the stochastic nature of evolution, its limited observability, and complex intra-population dynamics, this presents a significant challenge. In this paper, we explore techniques to control the evolutionary dynamics of a population, based on manipulation of one or two orthogonal selective pressures, which may in turn be coupled to mutagenesis. Our approach builds on past research in evolutionary biology that developed frameworks to study intra-population variant competition during asexual adaptive processes (i.e. clonal interference). Extending this theory, we design optimal control strategies for one (or more) selective pressures that can be used to maximise the rate of adaptation across a population as a whole. We introduce a theoretical modelling framework for this process, which we support with both simulations and preliminary experimental data, providing a concrete basis for emerging control approaches to directed evolution and evolution-aware design.
Open AccessOptimised control of adaptive evolution with competing selective pressures
The development of methods to understand and control the population dynamics of microbial evolution remains an outstanding question in synthetic biology and biotechnology more broadly. Due to the stochastic nature of evolution, its limited observability, and complex intra-population dynamics, this presents a significant challenge. In this paper, we explore techniques to control the evolutionary dynamics of a population, based on manipulation of one or two orthogonal selective pressures, which may in turn be coupled to mutagenesis. Our approach builds on past research in evolutionary biology that developed frameworks to study intra-population variant competition during asexual adaptive processes (i.e. clonal interference). Extending this theory, we design optimal control strategies for one (or more) selective pressures that can be used to maximise the rate of adaptation across a population as a whole. We introduce a theoretical modelling framework for this process, which we support with both simulations and preliminary experimental data, providing a concrete basis for emerging control approaches to directed evolution and evolution-aware design.
- 23 May 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (5) , 054076
Handheld Device for Noncontact Thermometry via Optically Detected Magnetic Resonance of Proximate Diamond Sensors
Optically detected magnetic resonance (ODMR) spectroscopy of defect-rich semiconductors is being increasingly exploited for realizing a variety of practical quantum sensing devices. A prime example is the on-going development of compact magnetometers based on the nitrogen-vacancy (N-) defect in diamond for the remote sensing of magnetic signals with high accuracy and sensitivity. In these applications, the ODMR-active material is integrated into the overall apparatus to form a self-contained sensor. However, some emerging applications require the sensing material to be in physical contact with an external object of interest, thus requiring an independent readout device. Here we present an ODMR meter, a compact device specially designed to allow convenient, contactless monitoring of ODMR in a target object, and demonstrate its application to temperature monitoring with N- defects. Our prototype is composed of a handheld readout head (integrating all the necessary optical components and a microwave antenna) and a control box connected to a laptop computer, all made primarily from commercial off-the-shelf components. We test our device using a N--rich bulk diamond as the object, demonstrate a temperature sensitivity of in static conditions, and demonstrate the feasibility of handheld operation. The limitations to measurement speed, sensitivity, and accuracy are discussed. The presented device may find immediate use in medical and industrial applications where accurate thermometry is required, and can be extended to magnetic field measurements.- 23 May 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (5) , 054076
Handheld Device for Noncontact Thermometry via Optically Detected Magnetic Resonance of Proximate Diamond Sensors
Optically detected magnetic resonance (ODMR) spectroscopy of defect-rich semiconductors is being increasingly exploited for realizing a variety of practical quantum sensing devices. A prime example is the on-going development of compact magnetometers based on the nitrogen-vacancy (N-) defect in diamond for the remote sensing of magnetic signals with high accuracy and sensitivity. In these applications, the ODMR-active material is integrated into the overall apparatus to form a self-contained sensor. However, some emerging applications require the sensing material to be in physical contact with an external object of interest, thus requiring an independent readout device. Here we present an ODMR meter, a compact device specially designed to allow convenient, contactless monitoring of ODMR in a target object, and demonstrate its application to temperature monitoring with N- defects. Our prototype is composed of a handheld readout head (integrating all the necessary optical components and a microwave antenna) and a control box connected to a laptop computer, all made primarily from commercial off-the-shelf components. We test our device using a N--rich bulk diamond as the object, demonstrate a temperature sensitivity of in static conditions, and demonstrate the feasibility of handheld operation. The limitations to measurement speed, sensitivity, and accuracy are discussed. The presented device may find immediate use in medical and industrial applications where accurate thermometry is required, and can be extended to magnetic field measurements.- 1 September 2022
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 4 (3) , 034404
Aberration control in quantitative widefield quantum microscopy
Widefield quantum microscopy based on nitrogen-vacancy (NV) centers in diamond has emerged as a powerful technique for quantitative mapping of magnetic fields with a sub-micrometer resolution. However, the accuracy of the technique has not been characterized in detail so far. Here, we show that optical aberrations in the imaging system may cause large systematic errors in the measured quantity beyond trivial blurring. We introduce a simple theoretical framework to model these effects, which extends the concept of a point spread function to the domain of spectral imaging. Using this model, the magnetic field imaging of test magnetic samples is simulated under various scenarios, and the resulting errors are quantified. We then apply the model to previously published data, show that apparent magnetic anomalies can be explained by the presence of optical aberrations, and demonstrate a post-processing technique to retrieve the source quantity with improved accuracy. This work presents a guide to predict and mitigate aberration induced artifacts in quantitative NV-based widefield imaging and in spectral imaging more generally.
- 1 September 2022
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 4 (3) , 034404
Aberration control in quantitative widefield quantum microscopy
Widefield quantum microscopy based on nitrogen-vacancy (NV) centers in diamond has emerged as a powerful technique for quantitative mapping of magnetic fields with a sub-micrometer resolution. However, the accuracy of the technique has not been characterized in detail so far. Here, we show that optical aberrations in the imaging system may cause large systematic errors in the measured quantity beyond trivial blurring. We introduce a simple theoretical framework to model these effects, which extends the concept of a point spread function to the domain of spectral imaging. Using this model, the magnetic field imaging of test magnetic samples is simulated under various scenarios, and the resulting errors are quantified. We then apply the model to previously published data, show that apparent magnetic anomalies can be explained by the presence of optical aberrations, and demonstrate a post-processing technique to retrieve the source quantity with improved accuracy. This work presents a guide to predict and mitigate aberration induced artifacts in quantitative NV-based widefield imaging and in spectral imaging more generally.
- 22 July 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (8) , 12580-12589
Varied Magnetic Phases in a van der Waals Easy-Plane Antiferromagnet Revealed by Nitrogen-Vacancy Center Microscopy
Interest in van der Waals materials often stems from a desire to miniaturize existing technologies by exploiting their intrinsic layered structures to create near-atomically thin components that do not suffer from surface defects. One appealing property is an easily switchable yet robust magnetic order, which is only sparsely demonstrated in the case of in-plane anisotropy. In this work, we use widefield nitrogen-vacancy (NV) center magnetic imaging to measure the properties of individual flakes of CuCrP2S6, a multiferroic van der Waals magnet known to exhibit weak easy-plane anisotropy in the bulk. We chart the crossover between the in-plane ferromagnetism in thin flakes down to the trilayer and the bulk behavior dominated by a low-field spin-flop transition. Further, by exploiting the directional dependence of NV center magnetometry, we are able to observe an instance of a predominantly out-of-plane ferromagetic phase near zero field, in contrast with our expectation and previous experiments on the bulk material. We attribute this to the presence of surface anisotropies caused by the sample preparation process or exposure to the ambient environment, which is expected to have more general implications for a broader class of weakly anisotropic van der Waals magnets.
- 22 July 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (8) , 12580-12589
Varied Magnetic Phases in a van der Waals Easy-Plane Antiferromagnet Revealed by Nitrogen-Vacancy Center Microscopy
Interest in van der Waals materials often stems from a desire to miniaturize existing technologies by exploiting their intrinsic layered structures to create near-atomically thin components that do not suffer from surface defects. One appealing property is an easily switchable yet robust magnetic order, which is only sparsely demonstrated in the case of in-plane anisotropy. In this work, we use widefield nitrogen-vacancy (NV) center magnetic imaging to measure the properties of individual flakes of CuCrP2S6, a multiferroic van der Waals magnet known to exhibit weak easy-plane anisotropy in the bulk. We chart the crossover between the in-plane ferromagnetism in thin flakes down to the trilayer and the bulk behavior dominated by a low-field spin-flop transition. Further, by exploiting the directional dependence of NV center magnetometry, we are able to observe an instance of a predominantly out-of-plane ferromagetic phase near zero field, in contrast with our expectation and previous experiments on the bulk material. We attribute this to the presence of surface anisotropies caused by the sample preparation process or exposure to the ambient environment, which is expected to have more general implications for a broader class of weakly anisotropic van der Waals magnets.
- 20 December 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (25) , 254002
An integrated widefield probe for practical diamond nitrogen-vacancy microscopy
The widefield diamond nitrogen-vacancy (NV) microscope is a powerful instrument for imaging magnetic fields. However, a key limitation impeding its wider adoption is its complex operation, in part due to the difficulty of precisely interfacing the sensor and sample to achieve optimum spatial resolution. Here, we demonstrate a solution to this interfacing problem that is practical and reliably minimizes NV-sample standoff. We built a compact widefield NV microscope, which incorporates an integrated widefield diamond probe with full position and angular control, and developed a systematic alignment procedure based on optical interference fringes. Using this platform, we imaged an ultrathin (1 nm) magnetic film test sample and conducted a detailed study of the spatial resolution. We reproducibly achieved an estimated NV-sample standoff (and hence spatial resolution) of at most across a field of view. Guided by these results, we suggest future improvements for approaching the optical diffraction limit. This work is a step toward realizing a widefield NV microscope suitable for routine high-throughput mapping of magnetic fields.- 20 December 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (25) , 254002
An integrated widefield probe for practical diamond nitrogen-vacancy microscopy
The widefield diamond nitrogen-vacancy (NV) microscope is a powerful instrument for imaging magnetic fields. However, a key limitation impeding its wider adoption is its complex operation, in part due to the difficulty of precisely interfacing the sensor and sample to achieve optimum spatial resolution. Here, we demonstrate a solution to this interfacing problem that is practical and reliably minimizes NV-sample standoff. We built a compact widefield NV microscope, which incorporates an integrated widefield diamond probe with full position and angular control, and developed a systematic alignment procedure based on optical interference fringes. Using this platform, we imaged an ultrathin (1 nm) magnetic film test sample and conducted a detailed study of the spatial resolution. We reproducibly achieved an estimated NV-sample standoff (and hence spatial resolution) of at most across a field of view. Guided by these results, we suggest future improvements for approaching the optical diffraction limit. This work is a step toward realizing a widefield NV microscope suitable for routine high-throughput mapping of magnetic fields.- 27 October 2021
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 77 (11) , 1437-1450
Data- and diversity-driven development of a Shotgun crystallization screen using the Protein Data Bank
Protein crystallization has for decades been a critical and restrictive step in macromolecular structure determination via X-ray diffraction. Crystallization typically involves a multi-stage exploration of the available chemical space, beginning with an initial sampling (screening) followed by iterative refinement (optimization). Effective screening is important for reducing the number of optimization rounds required, reducing the cost and time required to determine a structure. Here, an initial screen (Shotgun II) derived from analysis of the up-to-date Protein Data Bank (PDB) is proposed and compared with the previously derived (2014) Shotgun I screen. In an update to that analysis, it is clarified that the Shotgun approach entails finding the crystallization conditions that cover the most diverse space of proteins by sequence found in the PDB, which can be mapped to the well known maximum coverage problem in computer science. With this realization, it was possible to apply a more effective algorithm for selecting conditions. In-house data demonstrate that compared with alternatives, the Shotgun I screen has been remarkably successful over the seven years that it has been in use, indicating that Shotgun II is also likely to be a highly effective screen.
- 27 October 2021
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 77 (11) , 1437-1450
Data- and diversity-driven development of a Shotgun crystallization screen using the Protein Data Bank
Protein crystallization has for decades been a critical and restrictive step in macromolecular structure determination via X-ray diffraction. Crystallization typically involves a multi-stage exploration of the available chemical space, beginning with an initial sampling (screening) followed by iterative refinement (optimization). Effective screening is important for reducing the number of optimization rounds required, reducing the cost and time required to determine a structure. Here, an initial screen (Shotgun II) derived from analysis of the up-to-date Protein Data Bank (PDB) is proposed and compared with the previously derived (2014) Shotgun I screen. In an update to that analysis, it is clarified that the Shotgun approach entails finding the crystallization conditions that cover the most diverse space of proteins by sequence found in the PDB, which can be mapped to the well known maximum coverage problem in computer science. With this realization, it was possible to apply a more effective algorithm for selecting conditions. In-house data demonstrate that compared with alternatives, the Shotgun I screen has been remarkably successful over the seven years that it has been in use, indicating that Shotgun II is also likely to be a highly effective screen.
- Top Cited PapersOpen Access
- 19 October 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 130 (15) , 150902
Widefield quantum microscopy with nitrogen-vacancy centers in diamond: Strengths, limitations, and prospects
A dense layer of nitrogen-vacancy (NV) centers near the surface of a diamond can be interrogated in a widefield optical microscope to produce spatially resolved maps of local quantities such as magnetic field, electric field, and lattice strain, providing potentially valuable information about a sample or device placed in proximity. Since the first experimental realization of such a widefield NV microscope in 2010, the technology has seen rapid development and demonstration of applications in various areas across condensed matter physics, geoscience, and biology. This Perspective analyzes the strengths and shortcomings of widefield NV microscopy in order to identify the most promising applications and guide future development. We begin with a brief review of quantum sensing with ensembles of NV centers and the experimental implementation of widefield NV microscopy. We then compare this technology to alternative microscopy techniques commonly employed to probe magnetic materials and charge flow distributions. Current limitations in spatial resolution, measurement accuracy, magnetic sensitivity, operating conditions, and ease of use are discussed. Finally, we identify the technological advances that solve the aforementioned limitations and argue that their implementation would result in a practical, accessible, high-throughput widefield NV microscope.
- 19 October 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 130 (15) , 150902
Top Cited PapersOpen AccessWidefield quantum microscopy with nitrogen-vacancy centers in diamond: Strengths, limitations, and prospects
A dense layer of nitrogen-vacancy (NV) centers near the surface of a diamond can be interrogated in a widefield optical microscope to produce spatially resolved maps of local quantities such as magnetic field, electric field, and lattice strain, providing potentially valuable information about a sample or device placed in proximity. Since the first experimental realization of such a widefield NV microscope in 2010, the technology has seen rapid development and demonstration of applications in various areas across condensed matter physics, geoscience, and biology. This Perspective analyzes the strengths and shortcomings of widefield NV microscopy in order to identify the most promising applications and guide future development. We begin with a brief review of quantum sensing with ensembles of NV centers and the experimental implementation of widefield NV microscopy. We then compare this technology to alternative microscopy techniques commonly employed to probe magnetic materials and charge flow distributions. Current limitations in spatial resolution, measurement accuracy, magnetic sensitivity, operating conditions, and ease of use are discussed. Finally, we identify the technological advances that solve the aforementioned limitations and argue that their implementation would result in a practical, accessible, high-throughput widefield NV microscope.