Seyed Hassan Ashrafi Niaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seyed Hassan Ashrafi Niaki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Birgitte Bak‐Jensen
Department of Energy Technology Aalborg University Aalborg Denmark
1 shared publication- Habib Panahi
School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
1 shared publication Kamran Sharifabadi
Equinor ASA Fornebu Norway
1 shared publication- Majid Sanaye-Pasand
University of Tehran
1 shared publication - Reza Zamani
Faculty of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, Iran
1 shared publication Shuju Hu
Chinese Academy of Sciences Beijing China
1 shared publication
Latest Publications
- Open Access
- 28 December 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (2) , 187-199
DC protection coordination for multi‐terminal HB‐MMC‐based HVDC grids
Fast progress of High Voltage Direct Current (HVDC) technology has been considerable over the past decades. Emerging Modular Multilevel Converter (MMC) provides power systems with promising solutions to integrate large‐scale renewable energy sources, as well as multiple asynchronous power grids. Consequently, implementation of a multi‐terminal HVDC transmission system has been easier using MMC converters. However, protection of multi‐terminal MMC‐based HVDC grids under DC fault conditions is a challenge for the industry. This study sheds light on concept of system‐level DC protection coordination for multi‐terminal HVDC grids. Although, there are different protection methods for HVDC transmission systems including multi‐terminal ones, there are no well‐defined protection coordination strategies for transmission links protection and belonging HVDC converters under DC fault conditions. The proposed protection coordination prevents unnecessary tripping of MMCs in the multi‐area HVDC grids and supports the system with minimum effect on healthy parts. For the first time, different HVDC Converter Tripping (HCT) profiles are presented based on a fully selective protection strategy and their characteristics are discussed comprehensively. Simulation results demonstrate the effectiveness of the proposed strategy for multi‐terminal MMC‐based HVDC grids. The proposed coordination can be applied to DC grid code requirements of meshed HVDC grids in the future.
- 28 December 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (2) , 187-199
Open AccessDC protection coordination for multi‐terminal HB‐MMC‐based HVDC grids
Fast progress of High Voltage Direct Current (HVDC) technology has been considerable over the past decades. Emerging Modular Multilevel Converter (MMC) provides power systems with promising solutions to integrate large‐scale renewable energy sources, as well as multiple asynchronous power grids. Consequently, implementation of a multi‐terminal HVDC transmission system has been easier using MMC converters. However, protection of multi‐terminal MMC‐based HVDC grids under DC fault conditions is a challenge for the industry. This study sheds light on concept of system‐level DC protection coordination for multi‐terminal HVDC grids. Although, there are different protection methods for HVDC transmission systems including multi‐terminal ones, there are no well‐defined protection coordination strategies for transmission links protection and belonging HVDC converters under DC fault conditions. The proposed protection coordination prevents unnecessary tripping of MMCs in the multi‐area HVDC grids and supports the system with minimum effect on healthy parts. For the first time, different HVDC Converter Tripping (HCT) profiles are presented based on a fully selective protection strategy and their characteristics are discussed comprehensively. Simulation results demonstrate the effectiveness of the proposed strategy for multi‐terminal MMC‐based HVDC grids. The proposed coordination can be applied to DC grid code requirements of meshed HVDC grids in the future.
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 2220-2229
Fast Low Frequency Fault Location and Section Identification Scheme for VSC-Based Multi-Terminal HVDC Systems
Penetration of DC networks is rapidly increasing in modern power systems. As transient behavior of DC grids is different from that of AC ones, AC grid protection schemes might not be applicable to protect DC networks. Exact fault location is vital for protection of DC networks to reduce repair cost and achieve fast power recovery. This paper proposes a novel topology independent multi-terminal DC scheme to identify fault section and location for DC transmission systems. Voltage and current signals measured at the terminals are analyzed by the least squares error (LSE) algorithm. Then, the proposed scheme uses low frequency components of the signals to locate DC faults offline. Unlike some other methods, it does not require sophisticated sensors and hardware to capture very high frequency content of the signals. Hence, the proposed scheme can be implemented in practice without additional measuring infrastructure. The performance of the proposed scheme is evaluated under various fault conditions for different topologies of DC networks in both overhead lines and cables. Numerous simulations carried out demonstrate that the proposed scheme is quite accurate and provides excellent performance under different fault resistances, sections, and locations.
- 27 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 2220-2229
Fast Low Frequency Fault Location and Section Identification Scheme for VSC-Based Multi-Terminal HVDC Systems
Penetration of DC networks is rapidly increasing in modern power systems. As transient behavior of DC grids is different from that of AC ones, AC grid protection schemes might not be applicable to protect DC networks. Exact fault location is vital for protection of DC networks to reduce repair cost and achieve fast power recovery. This paper proposes a novel topology independent multi-terminal DC scheme to identify fault section and location for DC transmission systems. Voltage and current signals measured at the terminals are analyzed by the least squares error (LSE) algorithm. Then, the proposed scheme uses low frequency components of the signals to locate DC faults offline. Unlike some other methods, it does not require sophisticated sensors and hardware to capture very high frequency content of the signals. Hence, the proposed scheme can be implemented in practice without additional measuring infrastructure. The performance of the proposed scheme is evaluated under various fault conditions for different topologies of DC networks in both overhead lines and cables. Numerous simulations carried out demonstrate that the proposed scheme is quite accurate and provides excellent performance under different fault resistances, sections, and locations.