Atip Doolgindachbaporn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Atip Doolgindachbaporn has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Edward Simonson
Southampton Dielectric Consultants ltd, Southampton, U.K.
3 shared publications - George Callender
Tony Davies High Voltage Laboratory, University of Southampton, Southampton, U.K.
3 shared publications - Gordon Wilson
National Grid Electricity Transmission,Warwick,United Kingdom
3 shared publications - Paul. L. Lewin
Tony Davies High Voltage Laboratory, University of Southampton, Southampton, U.K.
2 shared publications - Chanchai Techawatcharapaikul
Department of Electrical Engineering, King Mongkuts University of Technology Thonburi (KMUTT), Bangkok, Thailand
1 shared publication - Nattapong Hatchavanich
King Mongkut's University of Technology Thonburi
1 shared publication
Latest Publications
- Open Access
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 56498-56515
AI-Based Data Fusion of IEC Methods With Dashboard Analytics for Hydrophobicity Evaluation of High-Voltage Insulators
Reliable assessment of insulator surface hydrophobicity is critical for the safety and continuity of power transmission and distribution networks and electrified transportation. While IEC TS 62073 prescribes three established methods—Contact angle(CA), Surface tension(SF), and Spray method(SP) —their deployment is hampered by operator subjectivity, environmental sensitivity, and the lack of an integrated interpretation. We present an AI-assisted, IEC-faithful framework that unifies contact angle, surface tension, and spray method into a single decision pipeline and exposes actionable outputs via a maintenance-oriented dashboard. Methodologically, Contact Angle is automated using Linear Regression Intersection for robust left/right contact estimation; Surface Tension is automated via cotton-tip last-frame and stationery-frame detection to time droplet reformation without manual frame picking; and Spray method leverages Zoning Feature Extraction with k-nearest neighbors, optionally complemented by an SVD–Mahalanobis classifier for borderline cases. Experiments on porcelain type 52-1 insulators under control conditions (30 °C, RH > 70%) comprise 90 droplet sequences for Contact angle, Surface tension and 2,800 Spray method images. As a result, applying these algorithms across the three methods yields interpretation accuracy exceeding 90%. Decision-level fusion improves consistency in intermediate classes while preserving IEC interpretability, and the dashboard provides transparent confidence and trend views for field engineers. In conclusion, the proposed algorithms increase the accuracy and reliability of insulator test interpretation and reduce ambiguity among visually similar features, enabling standards-compliant, reproducible assessments suitable for predictive-maintenance workflows in utilities and rail operations.
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 56498-56515
Open AccessAI-Based Data Fusion of IEC Methods With Dashboard Analytics for Hydrophobicity Evaluation of High-Voltage Insulators
Reliable assessment of insulator surface hydrophobicity is critical for the safety and continuity of power transmission and distribution networks and electrified transportation. While IEC TS 62073 prescribes three established methods—Contact angle(CA), Surface tension(SF), and Spray method(SP) —their deployment is hampered by operator subjectivity, environmental sensitivity, and the lack of an integrated interpretation. We present an AI-assisted, IEC-faithful framework that unifies contact angle, surface tension, and spray method into a single decision pipeline and exposes actionable outputs via a maintenance-oriented dashboard. Methodologically, Contact Angle is automated using Linear Regression Intersection for robust left/right contact estimation; Surface Tension is automated via cotton-tip last-frame and stationery-frame detection to time droplet reformation without manual frame picking; and Spray method leverages Zoning Feature Extraction with k-nearest neighbors, optionally complemented by an SVD–Mahalanobis classifier for borderline cases. Experiments on porcelain type 52-1 insulators under control conditions (30 °C, RH > 70%) comprise 90 droplet sequences for Contact angle, Surface tension and 2,800 Spray method images. As a result, applying these algorithms across the three methods yields interpretation accuracy exceeding 90%. Decision-level fusion improves consistency in intermediate classes while preserving IEC interpretability, and the dashboard provides transparent confidence and trend views for field engineers. In conclusion, the proposed algorithms increase the accuracy and reliability of insulator test interpretation and reduce ambiguity among visually similar features, enabling standards-compliant, reproducible assessments suitable for predictive-maintenance workflows in utilities and rail operations.
- 19 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 18, 362-365
Determination of Relative Thermal Performance of Power Transformers Using Data Driven Thermal Models
Reliability of power transformers is essential for managing electrical power transmission systems. Condition monitoring is needed to ensure that power transformers work as expected. A critical parameter used in condition monitoring is the hot spot temperature, which is governed by the thermal performance of the unit. Transformers are type tested during commissioning to guarantee that the temperature rise above ambient conditions does not exceed 78°C at their maximum capacity. However, thermal performance could change over a long period of time due to ageing. Generally, a transformer has sister units that are ordered at the same time and have the same specification, this group of units is referred to as a transformer family. Theoretically, thermal performance of transformers in the same family should be identical. However, due to ageing and different loading conditions, thermal performance could gradually diverge within a family. In this paper, thermal models for power transformers developed using Gaussian process regression are proposed. Once transformer thermal models for each transformer have been built, they are used to predict the transformer temperature of sister units. Typically, the average errors between the measurement and prediction made by the thermal model using its own data should be about zero, however, the average errors that are generated by the thermal model of the sister transformer could be positive or negative, if the thermal behavior between them is significantly divergent. The proposed method has been validated using data for three 400kV/275kV autotransformers and has been shown to work effectively.
- 19 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 18, 362-365
Determination of Relative Thermal Performance of Power Transformers Using Data Driven Thermal Models
Reliability of power transformers is essential for managing electrical power transmission systems. Condition monitoring is needed to ensure that power transformers work as expected. A critical parameter used in condition monitoring is the hot spot temperature, which is governed by the thermal performance of the unit. Transformers are type tested during commissioning to guarantee that the temperature rise above ambient conditions does not exceed 78°C at their maximum capacity. However, thermal performance could change over a long period of time due to ageing. Generally, a transformer has sister units that are ordered at the same time and have the same specification, this group of units is referred to as a transformer family. Theoretically, thermal performance of transformers in the same family should be identical. However, due to ageing and different loading conditions, thermal performance could gradually diverge within a family. In this paper, thermal models for power transformers developed using Gaussian process regression are proposed. Once transformer thermal models for each transformer have been built, they are used to predict the transformer temperature of sister units. Typically, the average errors between the measurement and prediction made by the thermal model using its own data should be about zero, however, the average errors that are generated by the thermal model of the sister transformer could be positive or negative, if the thermal behavior between them is significantly divergent. The proposed method has been validated using data for three 400kV/275kV autotransformers and has been shown to work effectively.
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 3133-3141
Data Driven Transformer Thermal Model for Condition Monitoring
Condition monitoring of power transformers, which are key components of electrical power systems, is essential to identify incipient faults and avoid catastrophic failures. In this paper machine learning algorithms, i.e., nonlinear autoregressive neural networks and support vector machines, are proposed to model the transformer thermal behavior for the purpose of monitoring. The thermal models are developed based on the historical measurements from nine transformers comprised of two 180-MVA units, four 240-MVA units and three 1000-MVA units. The data consist of load profile, tap position, winding indicator temperature (WTI) measurement, ambient temperature, wind speed and solar radiation. The results are validated against field measurements, and it is clearly demonstrated that the alternative algorithms surpass the IEEE Annex G thermal model. An incipient thermal fault identification algorithm is then proposed and successfully used to identify an issue using measurements taken in the field. This algorithm could be used to alert the operator and plan intervention accordingly.
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 3133-3141
Data Driven Transformer Thermal Model for Condition Monitoring
Condition monitoring of power transformers, which are key components of electrical power systems, is essential to identify incipient faults and avoid catastrophic failures. In this paper machine learning algorithms, i.e., nonlinear autoregressive neural networks and support vector machines, are proposed to model the transformer thermal behavior for the purpose of monitoring. The thermal models are developed based on the historical measurements from nine transformers comprised of two 180-MVA units, four 240-MVA units and three 1000-MVA units. The data consist of load profile, tap position, winding indicator temperature (WTI) measurement, ambient temperature, wind speed and solar radiation. The results are validated against field measurements, and it is clearly demonstrated that the alternative algorithms surpass the IEEE Annex G thermal model. An incipient thermal fault identification algorithm is then proposed and successfully used to identify an issue using measurements taken in the field. This algorithm could be used to alert the operator and plan intervention accordingly.
- 18 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 2163-2171
A Top-Oil Thermal Model for Power Transformers That Considers Weather Factors
The aim of this work is to develop a top-oil thermal model based on the thermal-electrical analogy and heat transfer principles that captures the thermal influence of prevailing winds and solar radiation which can be generally applied to large power transformers. The key improvements of the proposed thermal model are calculating the heat transfer coefficient of the radiator on the air side using the Nusselt number of combined forced and natural convection, and including the solar radiation as an addition heat source. The proposed model is validated with the operational measurements of 3 transformers that are comprised of a 120/240-MVA unit and two 90/180-MVA units. The results are also compared with the predictions based on the IEEE-Annex G model. The proposed model is more accurate over windy and summer periods as expected.
- 18 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (3) , 2163-2171
A Top-Oil Thermal Model for Power Transformers That Considers Weather Factors
The aim of this work is to develop a top-oil thermal model based on the thermal-electrical analogy and heat transfer principles that captures the thermal influence of prevailing winds and solar radiation which can be generally applied to large power transformers. The key improvements of the proposed thermal model are calculating the heat transfer coefficient of the radiator on the air side using the Nusselt number of combined forced and natural convection, and including the solar radiation as an addition heat source. The proposed model is validated with the operational measurements of 3 transformers that are comprised of a 120/240-MVA unit and two 90/180-MVA units. The results are also compared with the predictions based on the IEEE-Annex G model. The proposed model is more accurate over windy and summer periods as expected.