Bharath Ramakrishnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bharath Ramakrishnan has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Husam Alissa
Microsoft Corporation, Redmond, USA
3 shared publications Ashish Raniwala
Microsoft Azure, Redmond, WA, USA
2 shared publicationsBrijesh Warrier
Microsoft Azure, Redmond, WA, USA
2 shared publicationsChristian Belady
Microsoft CO+I, Redmond, WA, USA
2 shared publicationsIoannis Manousakis
Microsoft Azure, Redmond, WA, USA
2 shared publicationsMajid Jalili
The University of Texas at Austin, Austin, TX, USA
2 shared publications
Latest Publications
- 11 December 2024
- Published by ASME International in Journal of Electronic Packaging
- Vol. 147 (2) , 1-19
Understanding the Impact of Data Center Liquid Cooling on Energy and Performance of Machine Learning and Artificial Intelligence Workloads
Traditionally, data centers (DC) have used air cooling for IT equipment, but as graphics processing units (GPUs) evolve, they demand more power and sophisticated cooling. Aiming for efficiency, direct liquid cooling (DLC) emerges as a promising solution. We evaluated the effectiveness of DLC versus traditional air cooling on a Microsoft G50 GPU server performing artificial intelligence/machine learning (AI/ML) tasks. The results indicated that DLC greatly enhances GPU performance, increases efficiency by 2.7% in Gflops/s, cuts power usage by 12%, reduces execution times by up to 6.22%, and lowers chip temperatures by 20 °C compared to air cooling. Our research develops an overall performance metric that considers data center, hardware, and chip levels, concluding that DLC is extremely beneficial for AI workloads, increasing energy savings and balancing performance with power requirements.
- 11 December 2024
- Published by ASME International in Journal of Electronic Packaging
- Vol. 147 (2) , 1-19
Understanding the Impact of Data Center Liquid Cooling on Energy and Performance of Machine Learning and Artificial Intelligence Workloads
Traditionally, data centers (DC) have used air cooling for IT equipment, but as graphics processing units (GPUs) evolve, they demand more power and sophisticated cooling. Aiming for efficiency, direct liquid cooling (DLC) emerges as a promising solution. We evaluated the effectiveness of DLC versus traditional air cooling on a Microsoft G50 GPU server performing artificial intelligence/machine learning (AI/ML) tasks. The results indicated that DLC greatly enhances GPU performance, increases efficiency by 2.7% in Gflops/s, cuts power usage by 12%, reduces execution times by up to 6.22%, and lowers chip temperatures by 20 °C compared to air cooling. Our research develops an overall performance metric that considers data center, hardware, and chip levels, concluding that DLC is extremely beneficial for AI workloads, increasing energy savings and balancing performance with power requirements.
- 5 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Micro
- Vol. 42 (4) , 10-17
Overclocking in Immersion-Cooled Datacenters
Large cloud providers are starting to leverage liquid cooling for an increasing number of workloads. Liquid cooling enables providers to overclock server components, but they must tradeoff the potential increase in performance with higher power draw and reliability implications. We argue that two-phase immersion cooling is the most promising technology and, in that context, explore overclocking, its uses, and implications.
- 5 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Micro
- Vol. 42 (4) , 10-17
Overclocking in Immersion-Cooled Datacenters
Large cloud providers are starting to leverage liquid cooling for an increasing number of workloads. Liquid cooling enables providers to overclock server components, but they must tradeoff the potential increase in performance with higher power draw and reliability implications. We argue that two-phase immersion cooling is the most promising technology and, in that context, explore overclocking, its uses, and implications.
- Top Cited PapersOpen Access
- 19 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 11 (10) , 1703-1715
CPU Overclocking: A Performance Assessment of Air, Cold Plates, and Two-Phase Immersion Cooling
Computing capacity has always been on the upward climb due to the constant technological improvements in semiconductor manufacturing and packaging industry. This growth in computing capability is usually accompanied by a steep rise in heat flux density associated with the electronic component (CPUs or GPUs for example). High Performance Computing (HPC) data centers often employ several of these high-performance devices for crunching their enormous Artificial Intelligence (AI) or scientific computing workloads. State-of-the-art air cooling technologies throttle after a certain heat flux level and would require bigger heat sinks driving enormous airflow through it, which may not be desirable from a data center operation standpoint. Hence, a lookout for advanced thermal management techniques is quite imperative. In this article, a commercially available intel overclockable CPU i9-9900k was exercised with high performance workloads while employing and evaluating three different cooling technologies namely air-cooled, cold plates, and two-phase (2P) immersion. The high heat carrying capacity associated with cold plates and 2P immersion techniques outperformed the air-cooled solution by constantly yielding higher CPU clock rates up to 41% utilizing cold plates and 51% employing 2P immersion. The performance of cold plates and 2P immersion was evaluated at different functional points (different coolant operating temperatures and 2P coolant types for example) to understand how the technologies would respond in a legacy or modern data center operation. It was again observed that both 2P immersion technology and cold plates provided the least thermal resistance (as low as 0.247 °C/W) path to heat transfer and therefore provided higher computational performance and efficiency compared to air cooling. Further improvement in performance is not limited by cooling but by packaging constraints. Advanced packaging techniques coupled with minimizing the interfacial resistance can reap enhanced performance and energy efficiency gains using these modes of cooling. This article demonstrates the potential increase in VM (Virtual Machine) performance that can be attained using cold plates or 2P immersion. Authors recommend adoption of liquid cooling in early chip design and architecture phases. Finally, the article provides a generic overclocking methodology that the industry can use to qualify post-turbo server class chip performance.
- 19 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 11 (10) , 1703-1715
Top Cited PapersOpen AccessCPU Overclocking: A Performance Assessment of Air, Cold Plates, and Two-Phase Immersion Cooling
Computing capacity has always been on the upward climb due to the constant technological improvements in semiconductor manufacturing and packaging industry. This growth in computing capability is usually accompanied by a steep rise in heat flux density associated with the electronic component (CPUs or GPUs for example). High Performance Computing (HPC) data centers often employ several of these high-performance devices for crunching their enormous Artificial Intelligence (AI) or scientific computing workloads. State-of-the-art air cooling technologies throttle after a certain heat flux level and would require bigger heat sinks driving enormous airflow through it, which may not be desirable from a data center operation standpoint. Hence, a lookout for advanced thermal management techniques is quite imperative. In this article, a commercially available intel overclockable CPU i9-9900k was exercised with high performance workloads while employing and evaluating three different cooling technologies namely air-cooled, cold plates, and two-phase (2P) immersion. The high heat carrying capacity associated with cold plates and 2P immersion techniques outperformed the air-cooled solution by constantly yielding higher CPU clock rates up to 41% utilizing cold plates and 51% employing 2P immersion. The performance of cold plates and 2P immersion was evaluated at different functional points (different coolant operating temperatures and 2P coolant types for example) to understand how the technologies would respond in a legacy or modern data center operation. It was again observed that both 2P immersion technology and cold plates provided the least thermal resistance (as low as 0.247 °C/W) path to heat transfer and therefore provided higher computational performance and efficiency compared to air cooling. Further improvement in performance is not limited by cooling but by packaging constraints. Advanced packaging techniques coupled with minimizing the interfacial resistance can reap enhanced performance and energy efficiency gains using these modes of cooling. This article demonstrates the potential increase in VM (Virtual Machine) performance that can be attained using cold plates or 2P immersion. Authors recommend adoption of liquid cooling in early chip design and architecture phases. Finally, the article provides a generic overclocking methodology that the industry can use to qualify post-turbo server class chip performance.
- 29 August 2017
- Published by ASME International
Failure Analysis of Direct Liquid Cooling System in Data Centers
In this paper, the impact of direct liquid cooling (DLC) system failure on the IT equipment is studied experimentally. The main factors that are anticipated to affect the IT equipment response during failure are the CPU utilization, coolant set point temperature (SPT) and the server type. These factors are varied experimentally and the IT equipment response is studied in terms of chip temperature and power, CPU utilization and total server power. It was found that failure of the cooling system is hazardous and can lead to data center shutdown in less than a minute. Additionally, the CPU frequency throttling mechanism was found to be vital to understand the change in chip temperature, power, and utilization. Other mechanisms associated with high temperatures were also observed such as the leakage power and the fans speed change. Finally, possible remedies are proposed to reduce the probability and the consequences of the cooling system failure.
- 29 August 2017
- Published by ASME International
Failure Analysis of Direct Liquid Cooling System in Data Centers
In this paper, the impact of direct liquid cooling (DLC) system failure on the IT equipment is studied experimentally. The main factors that are anticipated to affect the IT equipment response during failure are the CPU utilization, coolant set point temperature (SPT) and the server type. These factors are varied experimentally and the IT equipment response is studied in terms of chip temperature and power, CPU utilization and total server power. It was found that failure of the cooling system is hazardous and can lead to data center shutdown in less than a minute. Additionally, the CPU frequency throttling mechanism was found to be vital to understand the change in chip temperature, power, and utilization. Other mechanisms associated with high temperatures were also observed such as the leakage power and the fans speed change. Finally, possible remedies are proposed to reduce the probability and the consequences of the cooling system failure.