SKSeyyed Rashid Khazeiynasab

Seyyed Rashid Khazeiynasab

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Seyyed Rashid Khazeiynasab has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Parallel Multi-Modal LSTM for Power System Model Calibration

    by Seyyed Rashid Khazeiynasab

    Renewable energies, smart loads, energy storage, and new market behavior are adding new sources of uncertainty to power systems. Therefore, planning in real-time and developing high-quality models is crucial to adapt to uncertainties. Model validation based on actual measurements is necessary for obtaining accurate representations of power systems dynamics with system uncertainties. This paper presents a new measurement-based method to calibrate the parameters of a synchronous generator by deep learning method based on the long-short term memory (LSTM) network. First, critical parameters are determined regarding the active/reactive behavior of the generator. Then, a parallel multimodal LSTM (PM-LSTM) is designed with flexible input time steps to capture important features of temporal patterns from time-series measurements. The extracted features are then fed into a dense layer to capture the joint representation of inputs. The simulations conducted for a hydro generator under different events show that the proposed method can estimate the model parameters accurately and efficiently.


  • Open Access

    WECC Composite Load Model Parameter Identification Using Deep Learning Approach

    by Seyyed Rashid Khazeiynasab

    The increased integration of distributed energy resources (DERs) has significantly changed the load composition. As compared to traditional static or induction motor loads, these inverter-based resources (IBRs) exhibit different behavior. Then, conventional dynamic load modeling with ZIP and induction motors (ZIP + IM) is no longer adequate to address the current load characteristic transitions. Western Electricity Coordinating Council (WECC) has developed the composite load model with distributed generation (CMPLDWG) to accurately represent static load, induction motors, and IBRs. In this paper, we propose a novel deep learning-based method using a conditional variational autoencoder (CVAE) to estimate the CMPLDWG model’s posterior distributions. The effectiveness of the proposed method is validated using an IEEE 39-bus test system. The results show that the proposed approach can accurately and efficiently estimate the parameters’ posterior distributions.

  • Open Access

    Measurement-Based Parameter Identification of DC-DC Converters with Adaptive Approximate Bayesian Computation

    by Seyyed Rashid Khazeiynasab, Issa Batarseh

    The recent advances in power plants and energy resources have extended the applications of DC-DC converters in the power systems (especially in the context of DC micro-grids). Parameter identification can extract the parameters of the converters and generate accurate discrete simulation models. In this paper, we propose a measurement-based converter parameter calibration method by an adaptive Approximate Bayesian Computation with sequential Monte Carlo sampler (ABC SMC), which estimates the parameters related to passive and parasitic components. At first, we propose to find suitable prior distribution for the parameter which we don't know the prior information about them. With having prior distributions, we can use the ABC SMC to find the exact values of the parameters of the converter. We chose the distance function carefully and based on the simulations we assigned the best method for the threshold sequencing. For improving the computationally of the algorithm, we propose an adaptive weight that helps the algorithm to find the optimal values with fewer simulations. The effectiveness of the proposed method is validated for a DC-DC buck converter. The results show that the proposed approach can accurately and efficiently estimate the posterior distributions of the buck parameters subject to gross errors in the prior distributions of the parameters. The proposed algorithm can also be applied to other parameter identifications and optimization applications such as rectifiers, filters, or power supplies, among others.

  • Power Plant Model Parameter Calibration Using Conditional Variational Autoencoder

    by Seyyed Rashid Khazeiynasab, Junbo Zhao, Issa Batarseh, Bendong Tan

    Accurate models of power plants play an important role in maintaining the reliable and secure grid operations. In this paper, we propose a synchrophasor measurement-based generator parameter calibration method by a novel deep learning method with high computational efficiency. An elementary effects-based approach is developed to identify the critical parameters from a nonlinear system with much better performance than the widely used trajectory sensitivity-based method. Then, synchrophasor measurement-based conditional variational autoencoder is developed to estimate the parameters’ posterior distributions even in the presence of a high-dimensional case with eighteen critical parameters to be calibrated. The effectiveness of the proposed method is validated for a hydro generator with a very detailed model. The results show that the proposed approach can accurately and efficiently estimate the generator parameters’ posterior distributions even when the parameters true values are not in support of the prior distribution.


  • Generator Parameter Calibration by Adaptive Approximate Bayesian Computation With Sequential Monte Carlo Sampler

    by Seyyed Rashid Khazeiynasab, Junjian Qi

    Secure power system operation relies on accurate steady-state and dynamic system models. It is thus crucial to carefully validate the models in power systems, in particular the generator models. The phasor measurement unit (PMU) technologies provide a low-cost option for generator model validation and parameter calibration without interfering with their operation. In this paper, an empirical parameter sensitivity Gramian based approach is developed to identify the critical parameters from a nonlinear system perspective. We further propose a synchrophasor measurement based generator parameter calibration method by adaptive Approximate Bayesian Computation with a sequential Monte Carlo sampler (A-ABC-SMC) that avoids directly dealing with likelihood functions. We propose adaptive threshold sequence scheme and perturbation kernel function in A-ABC-SMC in order to improve the computational efficiency. The effectiveness of the proposed method is validated for a hydro generator against multiple system events. The simulation results show that the proposed approach can accurately and efficiently estimate the full probabilistic posterior distributions of the generator parameters even when there are gross errors in the parameters’ prior distributions.


  • Open Access

    Resilience Analysis and Cascading FailureModeling of Power Systems under Extreme Temperatures

    by Seyyed Rashid Khazeiynasab, Junjian Qi

    In this paper, we propose an AC power flow based cascading failure model that explicitly considers external weather conditions, extreme temperatures in particular, and evaluates the impact of extreme temperature on the initiation and propagation of cascading blackouts. Specifically, load and dynamic line rating changes are modeled due to temperature disturbance, the probabilities for transmission line and generator outages are evaluated, and the timing for each type of events is carefully calculated to decide the actual event sequence. It should be emphasized that the correlated events, in the advent of external temperature changes, could together contribute to voltage instability. Besides, we model undervoltage load shedding and operator re-dispatch as control strategies for preventing the propagation of cascading failures. The effectiveness of the proposed model is verified by simulation results on the RTS-96 3-area system and it is found that temperature disturbances can lead to correlated load change and line/generator tripping, which together will greatly increase the risk of cascading and voltage instability. Critical temperature change, critical area with temperature disturbance, identification of most vulnerable buses, and comparison of different control strategies are also carefully investigated.