YCYangyang Cui

Yangyang Cui

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yangyang Cui has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Adaptive Fixed-Time Refined Disturbance Observer-Based Composite Control for Gimbal Servo System With Multiple Disturbances

    by Lina Zhang, Xiaoyu Guo, Xiuming Yao, Yangyang Cui

    Ensuring fast and accurate velocity-tracking performance of the control moment gyro gimbal servo system under multiple disturbances is crucial for high-precision attitude control of spacecrafts. Driven by the aforementioned demands, an adaptive fixed-time refined disturbance observer-based composite control scheme is proposed in this article. First, a gimbal servo system model is established by finely characterizing multiple heterogeneous disturbances and parameter perturbations under the difficulty of obtaining accurate rotor velocity. Then, an adaptive fixed-time refined disturbance observer framework is constructed to estimate multiple disturbances with unknown dynamics by fully utilizing disturbances prior information. Combined with observation results, a modified fixed-time controller with a novel fast terminal sliding mode surface is designed to compensate for matched and mismatched disturbances and ensure high-accuracy velocity tracking within a fixed time. Finally, experiment results confirm the validity of the proposed scheme.


  • Flow-Induced Magnetic Fields in Blood: High-Sensitivity Detection and Theoretical Analysis

    by Peilun Li, Yadan Zhang, Maotong Pang, Linqiang Mei, Shuo Wang, Yan Liu, Baosheng Wang, Guotai Wang, Xuan Li, Jiandong Liu, et al.

    The magnetic properties of blood have traditionally been investigated primarily in the context of its response to externally applied magnetic fields. In contrast, whether flowing blood itself can act as an intrinsic source of measurable magnetic fields has received limited direct experimental attention. In this study, we establish a dedicated, magnetically shielded experimental platform for measuring ultra-weak magnetic fields generated by flowing blood, and demonstrate that flowing blood generates reproducible and quantifiable magnetic signals under magnetically shielded conditions, in the absence of externally applied fields. Using an array of high-sensitivity magnetometers, stable magnetic field responses were detected in close proximity to flowing blood, exhibiting spatial distributions that were correlated with the flow direction. Control experiments using double distilled water and isotonic electrolyte solutions, together with systematic variations in flow rate and ionic concentration, indicate that the observed magnetic signals are primarily associated with flow-driven ionic charge transport rather than with cellular or protein constituents of blood. The signal amplitude increased with both flow rate and electrolyte conductivity, consistent with expectations for convective ionic transport in conductive fluids. A simplified phenomenological model further supports the interpretation that pressure-driven flow can give rise to transient ionic microcurrents through differential ion mobility and fluid–wall interactions, which may collectively generate detectable magnetic fields. Taken together, these results provide direct experimental evidence for flow-induced magnetic fields in blood within a controlled measurement framework. In addition to demonstrating the underlying physical phenomenon, this work establishes a systematic methodology for the detection and characterization of ultra-weak magnetic signals in conductive fluid flow, including interference control, quantitative signal evaluation, and validation under ultra-low-field conditions. This framework may support future measurement studies involving flow-induced magnetic fields in biological and conductive fluids.


  • Effects of Magnetocardiography Array Errors on Cardiac Source Imaging

    by Min Zhang, Yanmei Wang, Peilun Li, Yadan Zhang, Yangyang Cui, Min Xiang

    Magnetocardiography (MCG) source imaging allows high-precision three-dimensional localisation of regions with abnormal cardiac activity, playing a crucial role in disease diagnosis. In practical measurements, however, four key types of error in sensor arrays, i.e., crosstalk, gain error, angular error, and position error, can distort magnetic signals or the lead field matrix, thereby compromising imaging performance. To date, their impact on MCG source imaging has not been systematically assessed. In this study, we establish an evaluation framework and systematically investigate the effects of these errors for the first time. A comprehensive evaluation is conducted across three key aspects: reconstruction accuracy, spatial resolution, and the localisation accuracy of correlated sources. Our results indicate that all four error types degrade imaging performance to varying degrees. The detrimental influence of errors on reconstruction accuracy and spatial resolution becomes more severe as the signal-to-noise ratio increases. For the localisation of correlated sources, increases in the number of sources and the inter-source coupling strength further exacerbate the interference caused by array errors. Based on the configuration in this work, we derive conservative safe operating limits: crosstalk <1%, gain error <3%, angular error <1°, and position error <2 mm. Therefore, precise calibration of sensor parameters before MCG measurements is essential to ensure imaging performance. This study highlights that systematically evaluating array errors is critical for designing calibration strategies and supporting the clinical application of MCG systems.


  • Magnetocardiographic Simulation and Analysis of Cardiac QT Interval Disorders

    by Yadan Zhang, Yangyang Cui, Guiyu Bai, Min Xiang, Rui Shang, Jiaojiao Pang

    QT interval abnormalities, including prolonged and shortened QT, are linked to life-threatening arrhythmias. While electrocardiography (ECG) is commonly used for assessment, it has limitations in detecting subtle repolarization changes and spatial dispersion. Magnetocardiography (MCG) offers a potential alternative. We analyzed 735 subjects using MCG, including patients with congenital Long QT Syndrome (LQTS), Short QT Syndrome (SQTS), acquired QT prolongation, and healthy controls. QT intervals were measured by automated algorithms and manual annotation, and MCG data were compared to ECG. QTc, defined as the heart rate–corrected QT interval, was calculated for all subjects. A deep learning model was developed for classifying QT disorders. MCG QTc values were consistently longer than ECG values. LQTS patients had significantly prolonged MCG QTc (540 ± 35 ms), while SQTS patients showed shortened MCG QTc (310 ± 20 ms). MCG detected subtle QT prolongation in ECG-normal LQTS patients. The deep learning model achieved 90.8% overall accuracy in classifying QT disorders. MCG effectively measures QT interval abnormalities and identifies subtle repolarization changes missed by ECG, showing promise as a complementary diagnostic tool. MCG, combined with deep learning, provides a non-invasive, accurate approach to diagnosing QT disorders and could enhance personalized treatment strategies.

  • Disturbance Suppression Method for Three-Axis Active Magnetic Compensation System Based on ISMC-LESO

    by Ge Tian, Peiling Cui, Haitao Li, Yangyang Cui, Haifeng Zhang

    The three-axis active magnetic compensation (TAMC) system is widely used to suppress environmental magnetic disturbances in magnetically shielded room (MSR), enabling stable ultra-weak magnetic measurements with reduced cost. Nonlinear, time-varying, and coupled behaviors induced by the shielding material’s magnetic properties pose challenges to accurate modeling and disturbance suppression. A composite control strategy combining linear extended state observer (LESO) with integral sliding mode control (ISMC) is proposed. The LESO is implemented for each axis to provide real-time estimates of external disturbances, model uncertainties, and inter-axis coupling. Based on the LESO estimates, the ISMCs are designed to enhance robustness against parameter variations and nonlinearity while compensating for disturbances. Experimental results on a TAMC platform demonstrate that the proposed method effectively suppresses magnetic disturbances, which significantly reduces magnetic fluctuations inside the MSR and ensuring reliable conditions for high-precision biomagnetic measurements.

  • Fixed-Time Disturbance Observer-Based Composite Controller for CMG Gimbal Servo Systems With Prescribed Performance

    by Yangyang Cui, Yukai Zhu, Yan Meng, Baopeng Zhu, Yijia Xie, Jiyang Zhang

    Based on prior failures of the control moment gyroscope (CMG) deployed on the International Space Station, the velocity of the gimbal should be kept within the preset range. Furthermore, the high-maneuvering tasks of the spacecraft require fast convergence of the gimbal servo system. However, the tracking performance is particularly vulnerable to disturbances (e.g. cogging torque and nonlinear friction), thereby leading to performance degradation of the CMG and the spacecraft. To address the problem, this paper proposes a fixed-time disturbance observer-based fixed-time sliding mode controller that can preassign the gimbal velocity-tracking transient performance (maximum overshoot, convergence time) and steady-state performance (accuracy). Notably, both the disturbance-estimation errors and the gimbal velocity-tracking errors are rigorously proven to converge to the expected bounded regions within a fixed time that is independent of the initial state. Finally, the hardware-in-the-loop experiments demonstrate the effectiveness and advantages of the proposed method.


  • Input Excitation Disturbance Separator-Based Attitude Control for Flexible Spacecraft With Actuator Uncertainty

    by Yukai Zhu, Yongjian Yang, Yangyang Cui, Lei Guo, Weimin Bao

    Spacecraft attitude control performances are inevitably degraded by the composite disturbances such as flexible vibration and actuator uncertainty (e.g., partial loss of effectiveness and deadzone nonlinearity). These composite disturbances are inherently coupled with the attitude angular velocity and control input, exhibiting recessive, multiplicative, and additive forms. How to achieve the refined disturbance separation of these heterogeneous composite disturbances is crucial to improve the attitude control performances. In this article, a deep-coupled attitude dynamic model is established by sufficiently revealing the coupling relations of composite disturbances. Then, the disturbance separability analysis is carried out, and a novel input excitation disturbance separator (IEDS) is proposed. Driven by an ingeniously designed input excitation signal, the IEDS constructed by a refined disturbance observer (RDO) and a switch actuator uncertainty observer (SAUO) can estimate the flexible vibration disturbance and actuator uncertainty separately. Finally, some key parameters of actuator uncertainty, including the actuator effectiveness indicator and the dead-band sizes, are identified based on the IEDS output. By incorporating a sliding mode control in the feedback channel, a parameter identification-based composite attitude control is proposed, where the flexible vibration disturbance and actuator uncertainty can be compensated accurately. Numerical and experimental results are given to show the effectiveness of the proposed method.


  • Composite Antidisturbance Control for Electromechanical Fin Actuators With Deflection Angle Constraints

    by Yimeng Wang, Yangyang Cui, Chenliang Wang, Yu Mo, Houzhen Wei, Yongle Mao, Lei Guo

    In this paper, a composite anti-disturbance control method is proposed for electromechanical fin actuators with deflection angle constraints and multiple disturbances. Firstly, a mathematical model considering multiple disturbances of the electromechanical fin actuators is established. Secondly, the closed-loop uncertainty quantification analysis is conducted using an experimental platform, revealing the influence mechanism of multiple disturbances. Thirdly, a composite control scheme is designed based on the characteristics of the dominant disturbances, while accurately estimating, simultaneously compensating for and attenuating these disturbances. Specifically, a multi-harmonic disturbance observer is employed to precisely estimate the dominant disturbances, and a composite controller is developed to track the desired angle under deflection angle constraints. Finally, the experimental results demonstrate that, compared to the disturbance observer based PID control and active disturbance rejection control, the proposed scheme can enhance both disturbance estimation accuracy and deflection angle tracking performance.

  • Predefined-Time Antidisturbance Control for Periscope-Type Coarse Pointing Assembly Under Multiple Disturbances

    by Zeyu Bao, Yangyang Cui, Zhen Qin, Yongjian Yang, Baopeng Zhu, Yanran Wei, Yukai Zhu

    The coarse pointing assembly (CPA) is a key actuator for satellite laser communication. In actual laser alignment tasks over distances of thousands or even tens of thousands of kilometers, extremely high requirements are placed on the CPA's angle position-tracking precision and rapidity. However, the aforementioned ultrahigh performance requirements encounter multiple disturbances including satellite vibration, and friction torque from the drive motor. To this end, this article proposes a novel antidisturbance control with predefined-time performance to deal with this problem. First, by fully utilizing the prior information of disturbances, a refined predefined-time disturbance observer (RPTDO) is designed to quickly and accurately estimate these disturbances. Second, to accomplish simultaneous compensation and suppression of multiple disturbances, a predefined-time composite controller is presented based on the output of the RPTDO. Finally, the effectiveness and advancement of the proposed method are demonstrated by experimental results.