Ju-Hyung Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ju-Hyung Kim has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Dae-Jin Kim
Department of Architectural Engineering, Kyung Hee University, Yongin, South Korea
2 shared publications - Hong-Gun Park
Seoul National Univ
2 shared publications - Jang-Woon Baek
Department of Architectural Engineering, Kyung Hee University, Yongin, Gyeonggi, South Korea
2 shared publications - Mark F. Green
Queen’s University
2 shared publications R. Gordon Wight
2 shared publications- Young Hak Lee
Department of Architectural Engineering, Kyung Hee University, Yongin, Korea
2 shared publications
Latest Publications
- 10 February 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 120
Energy-equivalent neural networks for lateral load-displacement prediction in RC walls for seismic design
- 10 February 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 120
Energy-equivalent neural networks for lateral load-displacement prediction in RC walls for seismic design
- 1 February 2026
- Published by Elsevier in Structures
- Vol. 85
Shear strength prediction of RC beams using mechanics-informed machine learning
- 1 February 2026
- Published by Elsevier in Structures
- Vol. 85
Shear strength prediction of RC beams using mechanics-informed machine learning
- Open Access
- 20 July 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (11) , 3956-3972
Effect of slab stiffness on floor response spectrum and fragility of equipment in nuclear power plant building
- 20 July 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (11) , 3956-3972
Open AccessEffect of slab stiffness on floor response spectrum and fragility of equipment in nuclear power plant building
- 1 August 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (2) , 1251-1263
Dynamic properties of floating floor system and its influence on heavy-weight impact sound in residential buildings
We investigated the effects of a floating floor on heavy impact sound in the low-frequency range below 100 Hz with focus on the structural vibration. To verify the mechanism of amplifying the floor impact sound, field measurements were conducted before and after the installation of a floating floor while the other conditions were kept constant. Field tests were performed on five apartment units where the material properties of the resilient materials in the floating floors differed. Slab accelerations and sound pressure levels were measured simultaneously. The test results indicated that the low-frequency responses of slab acceleration and the corresponding heavy impact sounds were amplified in all apartment units after the installation of the floating floor, while high-frequency responses greater than 100 Hz were significantly reduced. The amplified responses were attributed to the interactions between the mortar plate (floating floor) and concrete slab, which were connected by a resilient material layer. The degree of amplification tended to increase as the loss factor of the resilient material decreased while the amplified frequency range was determined by the stiffness of the resilient material layer. The result was numerically verified using a simplified mass-spring model.
- 1 August 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (2) , 1251-1263
Dynamic properties of floating floor system and its influence on heavy-weight impact sound in residential buildings
We investigated the effects of a floating floor on heavy impact sound in the low-frequency range below 100 Hz with focus on the structural vibration. To verify the mechanism of amplifying the floor impact sound, field measurements were conducted before and after the installation of a floating floor while the other conditions were kept constant. Field tests were performed on five apartment units where the material properties of the resilient materials in the floating floors differed. Slab accelerations and sound pressure levels were measured simultaneously. The test results indicated that the low-frequency responses of slab acceleration and the corresponding heavy impact sounds were amplified in all apartment units after the installation of the floating floor, while high-frequency responses greater than 100 Hz were significantly reduced. The amplified responses were attributed to the interactions between the mortar plate (floating floor) and concrete slab, which were connected by a resilient material layer. The degree of amplification tended to increase as the loss factor of the resilient material decreased while the amplified frequency range was determined by the stiffness of the resilient material layer. The result was numerically verified using a simplified mass-spring model.
- 1 May 2016
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 113 (3) , 567-576
Thermomechanical Behavior of Near-Surface-Mounted Carbon Fiber-Reinforced Polymer Concrete Interface
- 1 May 2016
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 113 (3) , 567-576
Thermomechanical Behavior of Near-Surface-Mounted Carbon Fiber-Reinforced Polymer Concrete Interface
- 1 January 2016
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 113 (1)
Interface between Near-Surface-Mounted Carbon Fiber-Reinforced Polymer and Concrete in Thermal Distress
- 1 January 2016
- Published by American Concrete Institute in ACI Structural Journal
- Vol. 113 (1)
Interface between Near-Surface-Mounted Carbon Fiber-Reinforced Polymer and Concrete in Thermal Distress
- Open Access
- 1 November 2011
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 16 (4) , 215-222
Settlement Rehabilitation of a 35-Year-Old Building: Case Study Integrated with Analysis and Implementation
This paper presents a rehabilitation project concerning the settlement of a 35-year-old building. The foundation system of the northwest wing of the building consists of strip footings and slab on grade. Differential settlement results in significant cracking of the masonry partition walls located on the footing, and hence rehabilitation of the footing is required to stabilize the foundation system. Geotechnical and structural investigations are conducted, including site borings and analytical modeling on the basis of one-dimensional consolidation theory that is incorporated into a finite-element analysis. The predictive model exhibits that the differential settlement does not cause noticeable distress for the primary structural members, whereas the continued settlement affects use of the building. Site implementation is performed with the push-pile method to terminate the continuous settlement of the foundation.
- 1 November 2011
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 16 (4) , 215-222
Open AccessSettlement Rehabilitation of a 35-Year-Old Building: Case Study Integrated with Analysis and Implementation
This paper presents a rehabilitation project concerning the settlement of a 35-year-old building. The foundation system of the northwest wing of the building consists of strip footings and slab on grade. Differential settlement results in significant cracking of the masonry partition walls located on the footing, and hence rehabilitation of the footing is required to stabilize the foundation system. Geotechnical and structural investigations are conducted, including site borings and analytical modeling on the basis of one-dimensional consolidation theory that is incorporated into a finite-element analysis. The predictive model exhibits that the differential settlement does not cause noticeable distress for the primary structural members, whereas the continued settlement affects use of the building. Site implementation is performed with the push-pile method to terminate the continuous settlement of the foundation.
- 1 December 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 14 (6) , 647-658
Flexural Response of Concrete Beams Prestressed with AFRP Tendons: Numerical Investigation
This paper presents the flexure of concrete beams prestressed with aramid fiber-reinforced polymer (AFRP) tendons. Three-dimensional nonlinear finite-element analysis and iterative sectional analysis are conducted to predict the behavior of AFRP-prestressed members, including experimental validation. The beams are simply supported and monotonically loaded until failure occurs. The sectional properties of the beams include a reinforcement ratio of 0.15% to 0.36% and an Ig / Icr ratio of 25 to 77, where Ig and Icr are the gross and cracked moment of inertia, respectively. Various prestressing levels are applied to the beams to evaluate the load versus displacement response, variation of neutral axis depth, effective moment of inertia, and deformability of the beams. The applicability of code provisions and existing predictive equations are examined. The prestress level in the AFRP tendons significantly influences the flexural behavior of the beams, namely, cracking load, strain development of AFRP, and neut...
- 1 December 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 14 (6) , 647-658
Flexural Response of Concrete Beams Prestressed with AFRP Tendons: Numerical Investigation
This paper presents the flexure of concrete beams prestressed with aramid fiber-reinforced polymer (AFRP) tendons. Three-dimensional nonlinear finite-element analysis and iterative sectional analysis are conducted to predict the behavior of AFRP-prestressed members, including experimental validation. The beams are simply supported and monotonically loaded until failure occurs. The sectional properties of the beams include a reinforcement ratio of 0.15% to 0.36% and an Ig / Icr ratio of 25 to 77, where Ig and Icr are the gross and cracked moment of inertia, respectively. Various prestressing levels are applied to the beams to evaluate the load versus displacement response, variation of neutral axis depth, effective moment of inertia, and deformability of the beams. The applicability of code provisions and existing predictive equations are examined. The prestress level in the AFRP tendons significantly influences the flexural behavior of the beams, namely, cracking load, strain development of AFRP, and neut...