XLXiangyun Lan

Xiangyun Lan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiangyun Lan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Guangcai Wen

    State Key Laboratory of Gas Disaster Monitoring and Emergency Technology, No. 55, Shangqiao No. 3 Village, Shapingba District, Chongqing, China

    1 shared publication
  • Guangcai Wen

    School of Resources and Safety Engineering, Chongqing University, Chongqing 400044, China

    1 shared publication
  • Jinhua Chen

    National Key Laboratory of Gas Disaster Detecting, Preventing and Emergency Controlling, Chongqing, China

    1 shared publication
  • Lu Xiao

    China Coal Energy Research Institute Co., Ltd., Xi’an 710054, China

    1 shared publication
  • Qingming Long

    State Key Laboratory of Gas Disaster Monitoring and Emergency Technology, No. 55, Shangqiao No. 3 Village, Shapingba District, Chongqing, China

    1 shared publication
  • Song Yan

    State Key Laboratory for Mineral Deposit Research, School of Earth and Engineering, Nanjing University, Nanjing 210023, China

    1 shared publication

Latest Publications

  • Open Access

    An Experimental Study on the Particle Size and Shape Distribution of Coal Drill Cuttings by Dynamic Image Analysis

    by Zhigang Zhang, Xiangyun Lan, Guangcai Wen, Qingming Long, Xuelin Yang

    Particle size and shape distribution can be measured in great detail by dynamic image analysis (DIA). The narrow dispersion of repeated experiment results indicates that the particle size distribution can be obtained with high reliability. Particle size distribution can be better fitted to Rosin-Rammler equation than Gaudin-Schuhmann distribution and the lognormal distribution. The spread parameter () and the location parameters () of the Rosin-Rammler equation can be calculated precisely. We analyzed the similarities and differences between the different particle shape distributions. The distributions of form factor and circularity are right-skewed distributions, while the distributions of ellipse ratio, irregularity, and aspect ratio obey a normal distribution. By studying the relation between particle size and shape, we find a linear relationship between the ellipse ratio and the Legendre ellipse diameter on the logarithmic scale.


  • Open Access

    Oxidation and Characterization of Low-Concentration Gas in a High-Temperature Reactor

    by Jinhua Chen, Guangcai Wen, Song Yan, Xiangyun Lan, Lu Xiao

    To achieve the efficient utilization of low-concentration mine gas, reduce resource waste and alleviate environmental pollution, the high-temperature oxidation of low-concentration gas at a concentration range of 1.00% to 1.50%, which is directly discharged into the atmosphere during coal mine production, was carried out to recover heat for reuse. The gas oxidation equipment was improved for the heating process and the safety of low-concentration gas oxidation under a high-temperature environment was evaluated. The experimental results showed that the reactor could provide a 1000 °C high-temperature oxidation environment for gas oxidation after installing high-temperature resistant ceramics. The pressure variation curves of the reactor with air and different concentrations of gas were similar. Due to the thermal expansion, the air pressure slightly increased and then returned to normal pressure. In contrast, the low-concentration gas exhibited a stable pressure response in the high-temperature environment of 1000 °C. The outlet pressure was significantly greater than the inlet pressure, and the pressure difference between the inlet and outlet exhibited a trend to increase with the gas concentration. The minimum pressure difference was 4 kPa (air) and the maximum was 11 kPa (1.50% gas). The explosion limit varied with the temperature and the blend of oxidation products. The ratio of measured gas pressure to air pressure after oxidation was below the explosion criterion, indicating that the measured concentration of gas is still safe after the shift of the explosion limit, which provides a safe concentration range for the efficient use of low-concentration gas in the future.