Marvin Aaron Spurek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marvin Aaron Spurek has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Konrad Wegener
4 shared publications- Adriaan Bernardus Spierings
Inspire AG
3 shared publications Adriaan B. Spierings
Inspire AG, Innovation Center for Additive Manufacturing Switzerland (icams), St. Gallen, Switzerland
2 shared publicationsBernard Revaz
Sensima Inspection Sarl, Gland, Switzerland
2 shared publications- Christian Nelles
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
2 shared publications - David Maintz
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
2 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (22) , 3733
Multi-Parametric Spectral Detector CT for the Assessment of Focal Liver Lesions: Evaluation of Readers’ Diagnostic Confidence and Economic Effects
Background/Objectives: Characterization of small liver lesions on computed tomography (CT) remains challenging. This study evaluated whether spectral detector CT (SDCT) improves subjective diagnostic confidence in the characterization of focal hypoperfused liver lesions using additional spectral information and assessed its potential economic impact. Methods: In this IRB-approved retrospective study, 100 patients with 229 focal hypoperfused liver lesions who underwent SDCT were included. Images were evaluated in three consecutive reading sessions using (1) conventional polychromatic images (conv), (2) conventional plus monoenergetic images at 40, 50, and 60 keV (monoE), and (3) a multiparametric SDCT approach (mSDCT) combining conventional and spectral reconstructions, including iodine density (ID) and effective atomic number (Zeff) images. Lesions were characterized, and subjective diagnostic confidence was rated on a 5-point scale. Diagnostic performance was compared, and potential economic savings were estimated. Results: mSDCT yielded the highest diagnostic confidence in 130 lesions, compared with 36 lesions for conventional CT. Diagnostic confidence increased significantly from conventional CT through monoE to mSDCT (median scores: 3, 4, 4, 4, and 5 for conventional CT, 40-, 50-, and 60-keV monoE, and mSDCT, respectively; all p < 0.001). For lesions ≤ 10 mm, sensitivity was comparable between conventional CT and mSDCT, whereas mSDCT significantly improved specificity (85.0% vs. 97.9%) and diagnostic accuracy (86.4% vs. 96.7%; p < 0.001). Conclusion: Multiparametric SDCT significantly improves radiologists’ diagnostic confidence in characterizing focal hypoperfused liver lesions, particularly lesions ≤10 mm in oncologic patients. Increased diagnostic confidence may reduce the need for additional imaging or biopsy, potentially enabling faster and less costly diagnostic workups.
- 11 November 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (22) , 3733
Open AccessMulti-Parametric Spectral Detector CT for the Assessment of Focal Liver Lesions: Evaluation of Readers’ Diagnostic Confidence and Economic Effects
Background/Objectives: Characterization of small liver lesions on computed tomography (CT) remains challenging. This study evaluated whether spectral detector CT (SDCT) improves subjective diagnostic confidence in the characterization of focal hypoperfused liver lesions using additional spectral information and assessed its potential economic impact. Methods: In this IRB-approved retrospective study, 100 patients with 229 focal hypoperfused liver lesions who underwent SDCT were included. Images were evaluated in three consecutive reading sessions using (1) conventional polychromatic images (conv), (2) conventional plus monoenergetic images at 40, 50, and 60 keV (monoE), and (3) a multiparametric SDCT approach (mSDCT) combining conventional and spectral reconstructions, including iodine density (ID) and effective atomic number (Zeff) images. Lesions were characterized, and subjective diagnostic confidence was rated on a 5-point scale. Diagnostic performance was compared, and potential economic savings were estimated. Results: mSDCT yielded the highest diagnostic confidence in 130 lesions, compared with 36 lesions for conventional CT. Diagnostic confidence increased significantly from conventional CT through monoE to mSDCT (median scores: 3, 4, 4, 4, and 5 for conventional CT, 40-, 50-, and 60-keV monoE, and mSDCT, respectively; all p < 0.001). For lesions ≤ 10 mm, sensitivity was comparable between conventional CT and mSDCT, whereas mSDCT significantly improved specificity (85.0% vs. 97.9%) and diagnostic accuracy (86.4% vs. 96.7%; p < 0.001). Conclusion: Multiparametric SDCT significantly improves radiologists’ diagnostic confidence in characterizing focal hypoperfused liver lesions, particularly lesions ≤10 mm in oncologic patients. Increased diagnostic confidence may reduce the need for additional imaging or biopsy, potentially enabling faster and less costly diagnostic workups.
- Open Access
- 3 March 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (5) , 749
Opportunities and Challenges of Visual Large Language Models in Imaging Diagnostics: Lessons from Brain Metastasis Detection in Clinical MRI
Background/Objectives: To evaluate the diagnostic accuracy of two visual large language models (vLLMs), GPT-4o (OpenAI) and Claude Sonnet 3.5 (Anthropic), for detecting brain metastases in routine MRI using combined imaging and textual input. Methods: This retrospective study included 31 patients with and 46 without brain metastases with underlying melanoma (n = 24), lung cancer (n = 23), breast cancer (n = 17), or renal cell carcinoma (n = 13). In total, 100 MRI examinations (50 with, 50 without metastases) were provided to both vLLMs using a single representative slice per sequence, together with clinical history and the referring question. The generated free-text reports were evaluated for detection accuracy, overdiagnosis, correct sequence recognition, anatomical localization, lesion laterality, and lesion size estimation. Results: Both vLLMs showed perfect sensitivity (100% for both) but very low specificity (GPT-4o: 8%, Sonnet 3.5: 4%; p = 0.625), resulting in low diagnostic accuracy (GPT-4o: 54%, Sonnet 3.5: 52%; p = 0.625). Sequence identification was highly accurate in both models, with GPT-4o performing significantly better (100% vs. 93%; p < 0.05). Identification of the anatomical brain region (70% vs. 72%; p = 1.00) and lesion laterality (62% vs. 76%; p = 0.189) was comparable. Both models hallucinated additional lesions in 12% of cases. Lesion size measurements showed no significant differences between the models or in comparison with the radiologist. Conclusions: GPT-4o and Claude Sonnet 3.5 can generate radiological reports and detect brain metastases with excellent sensitivity, but their very low specificity, frequent hallucinations, and limited spatial reliability currently preclude clinical application. Future work should address how the balance between visual and textual input influences diagnostic behavior in vLLMs.
- 3 March 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (5) , 749
Open AccessOpportunities and Challenges of Visual Large Language Models in Imaging Diagnostics: Lessons from Brain Metastasis Detection in Clinical MRI
Background/Objectives: To evaluate the diagnostic accuracy of two visual large language models (vLLMs), GPT-4o (OpenAI) and Claude Sonnet 3.5 (Anthropic), for detecting brain metastases in routine MRI using combined imaging and textual input. Methods: This retrospective study included 31 patients with and 46 without brain metastases with underlying melanoma (n = 24), lung cancer (n = 23), breast cancer (n = 17), or renal cell carcinoma (n = 13). In total, 100 MRI examinations (50 with, 50 without metastases) were provided to both vLLMs using a single representative slice per sequence, together with clinical history and the referring question. The generated free-text reports were evaluated for detection accuracy, overdiagnosis, correct sequence recognition, anatomical localization, lesion laterality, and lesion size estimation. Results: Both vLLMs showed perfect sensitivity (100% for both) but very low specificity (GPT-4o: 8%, Sonnet 3.5: 4%; p = 0.625), resulting in low diagnostic accuracy (GPT-4o: 54%, Sonnet 3.5: 52%; p = 0.625). Sequence identification was highly accurate in both models, with GPT-4o performing significantly better (100% vs. 93%; p < 0.05). Identification of the anatomical brain region (70% vs. 72%; p = 1.00) and lesion laterality (62% vs. 76%; p = 0.189) was comparable. Both models hallucinated additional lesions in 12% of cases. Lesion size measurements showed no significant differences between the models or in comparison with the radiologist. Conclusions: GPT-4o and Claude Sonnet 3.5 can generate radiological reports and detect brain metastases with excellent sensitivity, but their very low specificity, frequent hallucinations, and limited spatial reliability currently preclude clinical application. Future work should address how the balance between visual and textual input influences diagnostic behavior in vLLMs.
- Open Access
- 6 November 2024
- Published by Elsevier in Additive Manufacturing
- Vol. 95
Effect of powder properties, process parameters, and recoating speed on powder layer properties measured by in-situ laser profilometry and part properties in laser powder bed fusion
- 6 November 2024
- Published by Elsevier in Additive Manufacturing
- Vol. 95
Open AccessEffect of powder properties, process parameters, and recoating speed on powder layer properties measured by in-situ laser profilometry and part properties in laser powder bed fusion
- Open Access
- 10 April 2024
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 10 (1) , 15-32
Influence of part temperature on in-situ monitoring of powder bed fusion of metals using eddy current testing
Powder bed fusion of metals (PBF-LB/M) is currently the most widely adopted additive manufacturing technology for the fabrication of metal parts. However, the inconsistent quality of PBF-LB/M-manufactured parts and high costs for part certification are impeding wider industrial adoption. In-situ monitoring technologies are expected to enable process control in order to ensure consistent quality, and to replace some of the post-process inspection steps, therefore, reducing part certification costs. Eddy current testing (ECT) is a standardized nondestructive testing technique, which can be used as an in-situ monitoring technology to measure the part quality during the PBF-LB/M build cycle. However, the process-induced complex temperature fields in PBF-LB/M parts during the build cycle are among the most relevant disturbances due to the temperature dependence of the electrical conductivity. This study investigates the process-induced temperature influence on in-situ monitoring of relative density using ECT. Parts made from AlSi10Mg were manufactured on a PBF-LB/M machine and the build cycle was monitored using ECT and an infrared camera, which was used to extract the part surface temperature right before the ECT measurement. The results demonstrate that the temperature increase of the parts during the build cycle decreases the electrical conductivity independently of the relative part density, which was measured via micro-computed tomography. Therefore, a temperature compensation method was proposed and applied demonstrating that a layer-to-layer difference of 0.15 % relative density can be detected via ECT. Consequently, it has been demonstrated that ECT is an effective in-situ monitoring technology for PBF-LB/M, even in the presence of temperature disparities within parts.
- 10 April 2024
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 10 (1) , 15-32
Open AccessInfluence of part temperature on in-situ monitoring of powder bed fusion of metals using eddy current testing
Powder bed fusion of metals (PBF-LB/M) is currently the most widely adopted additive manufacturing technology for the fabrication of metal parts. However, the inconsistent quality of PBF-LB/M-manufactured parts and high costs for part certification are impeding wider industrial adoption. In-situ monitoring technologies are expected to enable process control in order to ensure consistent quality, and to replace some of the post-process inspection steps, therefore, reducing part certification costs. Eddy current testing (ECT) is a standardized nondestructive testing technique, which can be used as an in-situ monitoring technology to measure the part quality during the PBF-LB/M build cycle. However, the process-induced complex temperature fields in PBF-LB/M parts during the build cycle are among the most relevant disturbances due to the temperature dependence of the electrical conductivity. This study investigates the process-induced temperature influence on in-situ monitoring of relative density using ECT. Parts made from AlSi10Mg were manufactured on a PBF-LB/M machine and the build cycle was monitored using ECT and an infrared camera, which was used to extract the part surface temperature right before the ECT measurement. The results demonstrate that the temperature increase of the parts during the build cycle decreases the electrical conductivity independently of the relative part density, which was measured via micro-computed tomography. Therefore, a temperature compensation method was proposed and applied demonstrating that a layer-to-layer difference of 0.15 % relative density can be detected via ECT. Consequently, it has been demonstrated that ECT is an effective in-situ monitoring technology for PBF-LB/M, even in the presence of temperature disparities within parts.
- Open Access
- 4 November 2022
- Published by Elsevier in Additive Manufacturing
- Vol. 60
In-situ monitoring of powder bed fusion of metals using eddy current testing
- 4 November 2022
- Published by Elsevier in Additive Manufacturing
- Vol. 60
Open AccessIn-situ monitoring of powder bed fusion of metals using eddy current testing
- Open Access
- 6 December 2021
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 7 (4) , 533-542
Influence of the particle size distribution of monomodal 316L powder on its flowability and processability in powder bed fusion
Powder bed fusion (PBF) is the most commonly adopted additive manufacturing process for fabricating complex metal parts via the layer-wise melting of a powder bed using a laser beam. However, the qualification of PBF-manufactured parts remains challenging and expensive, thereby limiting the broader industrialization of the technology. Powder characteristics significantly influence part properties, and understanding the influencing factors contributes to effective quality standards for PBF. In this study, the influence of the particle size distribution (PSD) median and width on powder flowability and part properties is investigated. Seven gas-atomized SS316L powders with monomodal PSDs, a median particle size ranging from 10 μm to 60 μm, and a distribution width of 15 μm and 30 μm were analyzed and subsequently processed. The PBF-manufactured parts were analyzed in terms of density and melt pool dimensions. Although powder flowability was inversely related to the median particle size, it was unrelated to the distribution width. An inverse relationship between the median particle size and the part density was observed; however, no link was found to the distribution width. Likely, the melt pool depth and width fluctuation significantly influence the part density. The melt pool depth decreases and the width fluctuation increases with an increasing median particle size.
- 6 December 2021
- Published by Springer Nature in Progress in Additive Manufacturing
- Vol. 7 (4) , 533-542
Open AccessInfluence of the particle size distribution of monomodal 316L powder on its flowability and processability in powder bed fusion
Powder bed fusion (PBF) is the most commonly adopted additive manufacturing process for fabricating complex metal parts via the layer-wise melting of a powder bed using a laser beam. However, the qualification of PBF-manufactured parts remains challenging and expensive, thereby limiting the broader industrialization of the technology. Powder characteristics significantly influence part properties, and understanding the influencing factors contributes to effective quality standards for PBF. In this study, the influence of the particle size distribution (PSD) median and width on powder flowability and part properties is investigated. Seven gas-atomized SS316L powders with monomodal PSDs, a median particle size ranging from 10 μm to 60 μm, and a distribution width of 15 μm and 30 μm were analyzed and subsequently processed. The PBF-manufactured parts were analyzed in terms of density and melt pool dimensions. Although powder flowability was inversely related to the median particle size, it was unrelated to the distribution width. An inverse relationship between the median particle size and the part density was observed; however, no link was found to the distribution width. Likely, the melt pool depth and width fluctuation significantly influence the part density. The melt pool depth decreases and the width fluctuation increases with an increasing median particle size.
- Open Access
Relative Density Measurement of PBF-Manufactured 316L and AlSi10Mg Samples via Eddy Current Testing
Powder bed fusion (PBF) is the most commonly used additive manufacturing process for fabricating complex metal parts via the layer-wise melting of powder. Despite the tremendous recent technological development of PBF, manufactured parts still lack consistent quality in terms of part properties such as dimensional accuracy, surface roughness, or relative density. In addition to process-inherent variability, this is mainly owing to a knowledge gap in the understanding of process influences and the inability to adequately control them during part production. Eddy current testing (ECT) is a well-established nondestructive testing technique primarily used to detect near-surface defects and measure material properties such as electrical conductivity in metal parts. Hence, it is an appropriate technology for the layer-wise measuring of the material properties of the fused material in PBF. This study evaluates ECT’s potential as a novel in situ monitoring technology for relative part density in PBF. Parts made from SS316L and AlSi10Mg with different densities are manufactured on a PBF machine. These parts are subsequently measured using ECT, as well as the resulting signals correlated with the relative part density. The results indicate a statistically significant and strong correlation (316L: r(8) = 0.998, p < 0.001, AlSi10Mg: r(8) = 0.992, p < 0.001) between relative part density and the ECT signal component, which is mainly affected by the electrical conductivity of the part. The results indicate that ECT has the potential to evolve into an effective technology for the layer-wise measuring of relative part density during the PBF process.
Open AccessRelative Density Measurement of PBF-Manufactured 316L and AlSi10Mg Samples via Eddy Current Testing
Powder bed fusion (PBF) is the most commonly used additive manufacturing process for fabricating complex metal parts via the layer-wise melting of powder. Despite the tremendous recent technological development of PBF, manufactured parts still lack consistent quality in terms of part properties such as dimensional accuracy, surface roughness, or relative density. In addition to process-inherent variability, this is mainly owing to a knowledge gap in the understanding of process influences and the inability to adequately control them during part production. Eddy current testing (ECT) is a well-established nondestructive testing technique primarily used to detect near-surface defects and measure material properties such as electrical conductivity in metal parts. Hence, it is an appropriate technology for the layer-wise measuring of the material properties of the fused material in PBF. This study evaluates ECT’s potential as a novel in situ monitoring technology for relative part density in PBF. Parts made from SS316L and AlSi10Mg with different densities are manufactured on a PBF machine. These parts are subsequently measured using ECT, as well as the resulting signals correlated with the relative part density. The results indicate a statistically significant and strong correlation (316L: r(8) = 0.998, p < 0.001, AlSi10Mg: r(8) = 0.992, p < 0.001) between relative part density and the ECT signal component, which is mainly affected by the electrical conductivity of the part. The results indicate that ECT has the potential to evolve into an effective technology for the layer-wise measuring of relative part density during the PBF process.