Zhaohui Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhaohui Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Delian Liu
School of Physics and Optoelectronic Engineering, Xidian University, Xi’an, Shaanxi 710071, China
1 shared publicationJianqi Zhang
School of Physics and Optoelectronic Engineering, Xidian University, Xi’an, Shaanxi 710071, China
1 shared publication- Mengjing Zhu
Xi’an University of Science and Technology, School of Communication and Information Engineering, Xi’an, China
1 shared publication - Wei Chen
School of Communication and Information Engineering, Xi’an University of Science and Technology, Xi’an, China
1 shared publication Wenying Xue
College of Communication and Information Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
1 shared publicationXiaorui Wang
School of Physics and Optoelectronic Engineering, Xidian University, Xi’an, Shaanxi 710071, China
1 shared publication
Latest Publications
- Open Access
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (04) , 045002-16
Improved U-net-based leukocyte segmentation method
Leukocytes are an important part of the body’s immune system. They are mainly made up of neutrophils, basophils, eosinophils, monocytes, and lymphocytes. The number and ratio of different types of leukocytes correspond to different diseases, so the accuracy of the leukocyte test is very important for the diagnosis of diseases. The traditional method of leukocyte testing is mainly manual microscopy, which requires two well-trained and experienced examiners to observe the morphology of leukocytes under the microscope to finalize the test results, which is not only time-consuming and inefficient but also highly subjective.1 With the improvement of computer performance and the increase of data volume in recent years, deep learning has also been widely applied to medical segmentation, and the proposed work is mainly based on various convolutional neural network schemes,2 such as SegNet,3,4 U-Net,4,5 and VGG-Unet.6 For the work on leukocyte segmentation, many researchers have achieved good results. Reena et al.7 used DeepLabv3+ architecture and ResNet-50 as a feature extraction network to segment each of the five types of leukocytes, and the final average segmentation accuracy was 96.1% and intersection-union accuracy was 92.1%; Lu et al.8 proposed a WBC-Net model based on UNet++ and ResNet to segment individual leukocytes, mainly by designing a context-aware feature encoder with residual blocks to extract multiscale features and introducing hybrid jump paths on dense convolutional blocks to acquire and fuse image features at different scales, which finally achieved good results on four publicly available datasets. Li et al.9 proposed a segmentation algorithm based on the U-Net model with dual-path and void space pyramidal pooling to achieve pixel-level segmentation of blood leukocytes, mainly by introducing a dual-path network in the feature encoder to extract multiscale features of leukocytes in images and using a void space pyramidal pooling module to enhance the feature extraction capability of the network, and the research results show that its mIoU value can reach above 0.97.
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (04) , 045002-16
Open AccessImproved U-net-based leukocyte segmentation method
Leukocytes are an important part of the body’s immune system. They are mainly made up of neutrophils, basophils, eosinophils, monocytes, and lymphocytes. The number and ratio of different types of leukocytes correspond to different diseases, so the accuracy of the leukocyte test is very important for the diagnosis of diseases. The traditional method of leukocyte testing is mainly manual microscopy, which requires two well-trained and experienced examiners to observe the morphology of leukocytes under the microscope to finalize the test results, which is not only time-consuming and inefficient but also highly subjective.1 With the improvement of computer performance and the increase of data volume in recent years, deep learning has also been widely applied to medical segmentation, and the proposed work is mainly based on various convolutional neural network schemes,2 such as SegNet,3,4 U-Net,4,5 and VGG-Unet.6 For the work on leukocyte segmentation, many researchers have achieved good results. Reena et al.7 used DeepLabv3+ architecture and ResNet-50 as a feature extraction network to segment each of the five types of leukocytes, and the final average segmentation accuracy was 96.1% and intersection-union accuracy was 92.1%; Lu et al.8 proposed a WBC-Net model based on UNet++ and ResNet to segment individual leukocytes, mainly by designing a context-aware feature encoder with residual blocks to extract multiscale features and introducing hybrid jump paths on dense convolutional blocks to acquire and fuse image features at different scales, which finally achieved good results on four publicly available datasets. Li et al.9 proposed a segmentation algorithm based on the U-Net model with dual-path and void space pyramidal pooling to achieve pixel-level segmentation of blood leukocytes, mainly by introducing a dual-path network in the feature encoder to extract multiscale features of leukocytes in images and using a void space pyramidal pooling module to enhance the feature extraction capability of the network, and the research results show that its mIoU value can reach above 0.97.
- Open Access
- 1 February 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2209 (1) , 012006
Measuring the orbital angular momentum mode of vortex beam based on phase matching sequence
Measuring the orbital angular momentum(OAM) mode of vortex beams is of great significance in applications based on vortex beams.we propose a method of phase matching characteristics of vortex beams to measure the OAM mode. The method first use a high-speed spatial light modulator(SLM) to sequentially load a set of helical phase sequence images, so that the vortex beam is modulated by this SLM. Then obtain the modulated optical field through pinhole filtering, and then the synchronized tilt phase modulation is performed by the 4f system and high-speed SLM. When the OAM mode of vortex beam is opposite to the topological charge of helical phase image, that is, the incident vortex beam degenerates to the fundamental Gaussian mode beam,and through our optical system, the output plane obtained a indicating spot with the position related to the OAM mode. The Simulation and experimental results show that the method obtains a clear OAM mode indicating spot on the final output plane, which verifies the theoretical derivation.
- 1 February 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2209 (1) , 012006
Open AccessMeasuring the orbital angular momentum mode of vortex beam based on phase matching sequence
Measuring the orbital angular momentum(OAM) mode of vortex beams is of great significance in applications based on vortex beams.we propose a method of phase matching characteristics of vortex beams to measure the OAM mode. The method first use a high-speed spatial light modulator(SLM) to sequentially load a set of helical phase sequence images, so that the vortex beam is modulated by this SLM. Then obtain the modulated optical field through pinhole filtering, and then the synchronized tilt phase modulation is performed by the 4f system and high-speed SLM. When the OAM mode of vortex beam is opposite to the topological charge of helical phase image, that is, the incident vortex beam degenerates to the fundamental Gaussian mode beam,and through our optical system, the output plane obtained a indicating spot with the position related to the OAM mode. The Simulation and experimental results show that the method obtains a clear OAM mode indicating spot on the final output plane, which verifies the theoretical derivation.
- Open Access
- 2 December 2015
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2015, 1-9
Novel Spatiotemporal Filter for Dim Point Targets Detection in Infrared Image Sequences
Dim point target detection is of great importance in both civil and military fields. In this paper a novel spatiotemporal filter is proposed to incorporate both the spatial and temporal features of moving dim point targets. Since targets are expected to be detected as far as possible, in this situation, they have no texture features in spatial dimensions, appearing like isolated points. Based on the attributes, potential targets are extracted by searching the local maximum point in a sliding window. And the potential targets are then correlated based on target moving patterns. After combining local maximum points and target moving patterns, structure background in infrared scene is removed. Next, the temporal profiles of infrared sense are reviewed and examined. By a new max-median filter performing on temporal profiles, the intensity of target pulse signal is extracted. Finally, each temporal profile is divided into several pieces to estimate the variance of the temporal profiles, which leads to a new detection metric. The proposed approach is tested via several infrared image sequences. The results show that our proposed method can significantly reduce the complex background in aerial infrared image sequence and have a good detection performance.
- 2 December 2015
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2015, 1-9
Open AccessNovel Spatiotemporal Filter for Dim Point Targets Detection in Infrared Image Sequences
Dim point target detection is of great importance in both civil and military fields. In this paper a novel spatiotemporal filter is proposed to incorporate both the spatial and temporal features of moving dim point targets. Since targets are expected to be detected as far as possible, in this situation, they have no texture features in spatial dimensions, appearing like isolated points. Based on the attributes, potential targets are extracted by searching the local maximum point in a sliding window. And the potential targets are then correlated based on target moving patterns. After combining local maximum points and target moving patterns, structure background in infrared scene is removed. Next, the temporal profiles of infrared sense are reviewed and examined. By a new max-median filter performing on temporal profiles, the intensity of target pulse signal is extracted. Finally, each temporal profile is divided into several pieces to estimate the variance of the temporal profiles, which leads to a new detection metric. The proposed approach is tested via several infrared image sequences. The results show that our proposed method can significantly reduce the complex background in aerial infrared image sequence and have a good detection performance.