Julia Bauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Julia Bauer has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
- Jürgen Debus
Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
8 shared publications Jürgen Debus
Department of Radiation Oncology and Heidelberg Ion Beam Therapy Center, Heidelberg University Hospital, Heidelberg, Germany; Heidelberg Institute for Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany; Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
7 shared publications- Katia Parodi
Ludwig-Maximilians-Universität München
5 shared publications - Klaus Herfarth
Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
4 shared publications - Thomas Haberer
Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
4 shared publications Katharina Seidensaal
Department of Radiation Oncology and Heidelberg Ion Beam Therapy Center (HIT), Heidelberg University Hospital, Heidelberg, Germany
3 shared publications
Latest Publications
- 19 November 2026
- Published by Taylor & Francis
- p. 241-327
Treatment Planning
- Open Access
- 15 November 2026
- Published by Elsevier in Radiotherapy and Oncology
- p. 111873
Independent validation of a predictive risk model for contrast-enhancing brain lesions supports enhanced periventricular radiosensitivity and variable proton RBE
- 15 November 2026
- Published by Elsevier in Radiotherapy and Oncology
- p. 111873
Open AccessIndependent validation of a predictive risk model for contrast-enhancing brain lesions supports enhanced periventricular radiosensitivity and variable proton RBE
- Open Access
- 27 June 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 222, 111674
Early ADC changes in risk-model-defined brain regions precede contrast-enhancing lesions after proton therapy for low-grade glioma
- 27 June 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 222, 111674
Open AccessEarly ADC changes in risk-model-defined brain regions precede contrast-enhancing lesions after proton therapy for low-grade glioma
- Open Access
- 6 December 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 57, 101092
Prospective controlled study comparing patient-reported outcomes after daily online adaptive radiotherapy or conventional IGRT in patients with prostate cancer
- 6 December 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 57, 101092
Open AccessProspective controlled study comparing patient-reported outcomes after daily online adaptive radiotherapy or conventional IGRT in patients with prostate cancer
- Open Access
- 1 November 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 214, 111244
Radiation dose inaccuracies near patient-specific osteosynthesis plates: an ex vivo dosimetric study
- 1 November 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 214, 111244
Open AccessRadiation dose inaccuracies near patient-specific osteosynthesis plates: an ex vivo dosimetric study
- Open Access
- 17 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145027
An analytical approach to predict 3D positron emitter distribution in carbon ion therapy
Objective. Carbon ion therapy could benefit from range verification due to its sensitivity to range uncertainties. Positron emission tomography (PET) aids in this and comparing PET signals to a predicted positron emitter distribution (PED) is one viable approach. Monte Carlo (MC) simulations are one way to predict PED but are computationally intensive and time-consuming. To address this, an analytical approach was previously suggested to predict 1D PED from depth dose profiles. Here we aim to develop a computational framework for 3D PED prediction in carbon ion therapy, building on the 1D approach to provide a faster method than MC simulations, with potential for integration into treatment planning systems (TPS). Approach. The 1D approach was revised by considering more PEs channels and introducing new modeling functions. A mapping process for handling longitudinal heterogeneity effects in projectile PED was developed. Then, a dedicated framework for 3D PED generation based on a pencil beam algorithm (PBA) and the updated 1D method was proposed. Validation was performed through in-silico studies against MC calculations for several phantoms as well as realistic computed tomography scans from patient data. Main results. For range assessment, the differences between distal fall-off positions of predicted and simulated 1D PED profiles were calculated to be below 0.8 mm for all validation cases. The comparison of predicted 3D PED with simulated results was performed by global gamma index analysis using the 2%/2 mm and 1%/1 mm criteria. For patient cases, the passing rates for 1%/1 mm criteria were above 95%. Significance. These results demonstrated the capability of our approach to predict 3D PED with good accuracy in terms of range and magnitude, paving the way to future implementation in a TPS, which commonly relies on PBA for 12C ions. Moreover, a significant speed-up compared to MC simulations was achieved, with future speed-optimized implementations.
- 17 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (14) , 145027
Open AccessAn analytical approach to predict 3D positron emitter distribution in carbon ion therapy
Objective. Carbon ion therapy could benefit from range verification due to its sensitivity to range uncertainties. Positron emission tomography (PET) aids in this and comparing PET signals to a predicted positron emitter distribution (PED) is one viable approach. Monte Carlo (MC) simulations are one way to predict PED but are computationally intensive and time-consuming. To address this, an analytical approach was previously suggested to predict 1D PED from depth dose profiles. Here we aim to develop a computational framework for 3D PED prediction in carbon ion therapy, building on the 1D approach to provide a faster method than MC simulations, with potential for integration into treatment planning systems (TPS). Approach. The 1D approach was revised by considering more PEs channels and introducing new modeling functions. A mapping process for handling longitudinal heterogeneity effects in projectile PED was developed. Then, a dedicated framework for 3D PED generation based on a pencil beam algorithm (PBA) and the updated 1D method was proposed. Validation was performed through in-silico studies against MC calculations for several phantoms as well as realistic computed tomography scans from patient data. Main results. For range assessment, the differences between distal fall-off positions of predicted and simulated 1D PED profiles were calculated to be below 0.8 mm for all validation cases. The comparison of predicted 3D PED with simulated results was performed by global gamma index analysis using the 2%/2 mm and 1%/1 mm criteria. For patient cases, the passing rates for 1%/1 mm criteria were above 95%. Significance. These results demonstrated the capability of our approach to predict 3D PED with good accuracy in terms of range and magnitude, paving the way to future implementation in a TPS, which commonly relies on PBA for 12C ions. Moreover, a significant speed-up compared to MC simulations was achieved, with future speed-optimized implementations.
- Open Access
- 12 February 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 188, 109777
Real-time adaptive proton therapy: An AI-based spatio-temporal mono-energetic dose calculation model (CC-LSTM)
- 12 February 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 188, 109777
Open AccessReal-time adaptive proton therapy: An AI-based spatio-temporal mono-energetic dose calculation model (CC-LSTM)
- 12 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (4) , 045018
Enhancing U-Net-based Pseudo-CT generation from MRI using CT-guided bone segmentation for radiation treatment planning in head & neck cancer patients
Objective. This study investigates the effects of various training protocols on enhancing the precision of MRI-only Pseudo-CT generation for radiation treatment planning and adaptation in head & neck cancer patients. It specifically tackles the challenge of differentiating bone from air, a limitation that frequently results in substantial deviations in the representation of bony structures on Pseudo-CT images. Approach. The study included 25 patients, utilizing pre-treatment MRI-CT image pairs. Five cases were randomly selected for testing, with the remaining 20 used for model training and validation. A 3D U-Net deep learning model was employed, trained on patches of size 643 with an overlap of 323. MRI scans were acquired using the Dixon gradient echo (GRE) technique, and various contrasts were explored to improve Pseudo-CT accuracy, including in-phase, water-only, and combined water-only and fat-only images. Additionally, bone extraction from the fat-only image was integrated as an additional channel to better capture bone structures on Pseudo-CTs. The evaluation involved both image quality and dosimetric metrics. Main results. The generated Pseudo-CTs were compared with their corresponding registered target CTs. The mean absolute error (MAE) and peak signal-to-noise ratio (PSNR) for the base model using combined water-only and fat-only images were 19.20 ± 5.30 HU and 57.24 ± 1.44 dB, respectively. Following the integration of an additional channel using a CT-guided bone segmentation, the model’s performance improved, achieving MAE and PSNR of 18.32 ± 5.51 HU and 57.82 ± 1.31 dB, respectively. The measured results are statistically significant, with a p-value < 0.05. The dosimetric assessment confirmed that radiation treatment planning on Pseudo-CT achieved accuracy comparable to conventional CT. Significance. This study demonstrates improved accuracy in bone representation on Pseudo-CTs achieved through a combination of water-only, fat-only and extracted bone images; thus, enhancing feasibility of MRI-based simulation for radiation treatment planning.
- 12 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (4) , 045018
Enhancing U-Net-based Pseudo-CT generation from MRI using CT-guided bone segmentation for radiation treatment planning in head & neck cancer patients
Objective. This study investigates the effects of various training protocols on enhancing the precision of MRI-only Pseudo-CT generation for radiation treatment planning and adaptation in head & neck cancer patients. It specifically tackles the challenge of differentiating bone from air, a limitation that frequently results in substantial deviations in the representation of bony structures on Pseudo-CT images. Approach. The study included 25 patients, utilizing pre-treatment MRI-CT image pairs. Five cases were randomly selected for testing, with the remaining 20 used for model training and validation. A 3D U-Net deep learning model was employed, trained on patches of size 643 with an overlap of 323. MRI scans were acquired using the Dixon gradient echo (GRE) technique, and various contrasts were explored to improve Pseudo-CT accuracy, including in-phase, water-only, and combined water-only and fat-only images. Additionally, bone extraction from the fat-only image was integrated as an additional channel to better capture bone structures on Pseudo-CTs. The evaluation involved both image quality and dosimetric metrics. Main results. The generated Pseudo-CTs were compared with their corresponding registered target CTs. The mean absolute error (MAE) and peak signal-to-noise ratio (PSNR) for the base model using combined water-only and fat-only images were 19.20 ± 5.30 HU and 57.24 ± 1.44 dB, respectively. Following the integration of an additional channel using a CT-guided bone segmentation, the model’s performance improved, achieving MAE and PSNR of 18.32 ± 5.51 HU and 57.82 ± 1.31 dB, respectively. The measured results are statistically significant, with a p-value < 0.05. The dosimetric assessment confirmed that radiation treatment planning on Pseudo-CT achieved accuracy comparable to conventional CT. Significance. This study demonstrates improved accuracy in bone representation on Pseudo-CTs achieved through a combination of water-only, fat-only and extracted bone images; thus, enhancing feasibility of MRI-based simulation for radiation treatment planning.
- Open Access
- 16 November 2024
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 14, 100636
Evaluation of Pelvic MRI-to-CT Deformable Registration for Adaptive MR-Guided Particle Therapy
- 16 November 2024
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 14, 100636
Open AccessEvaluation of Pelvic MRI-to-CT Deformable Registration for Adaptive MR-Guided Particle Therapy