Shulian Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shulian Zhang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Fei Li-Gang
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments, Tsinghua University, Beijing 100084
2 shared publications- Gang Liu
Shandong Provincial Key Laboratory of Oil, Gas and New Energy Storage and Transportation Safety, China University of Petroleum (East China), Qingdao, Shandong, China
2 shared publications Wan Xin-Jun
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments, Tsinghua University, Beijing 100084
2 shared publicationsYequn Zhou
Department of Neonatology, Children's Hospital of Fudan University, National Children's Medical Center, Shanghai, China
2 shared publicationsYi Dai
2 shared publicationsYidong Tan
State Key Lab of Precision Measurement Technology and Instruments, Department of Precision Instruments, Tsinghua University, Beijing
2 shared publications
Latest Publications
- 27 July 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 419, 138252
Carbon footprints in pork production and consumption in China from 2005 to 2020
- 27 July 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 419, 138252
Carbon footprints in pork production and consumption in China from 2005 to 2020
- Open Access
- 3 September 2021
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 9
Ten-Year Trend of Retinopathy of Prematurity Among Extremely Preterm Infants in One Neonatal Intensive Care Unit in China
Background: Extremely preterm (EP) infants are at the highest risk of retinopathy of prematurity (ROP). With more EP infants survived in China, recent data of ROP is lacking. The aim of the study is to report the trend of incidence of ROP among EP infants in a large neonatal intensive care unit in China over the past 10-year period, in relation with the overall survival rate and the change of oxygen saturation targets.Methods: This retrospective cohort study enrolled all EP infants born before 28 weeks' gestation and admitted to one of the largest tertiary neonatal intensive care units in China from 2010 to 2019. Data were compared between two time periods according to different oxygen saturation targets: 2010–2014 (P1) with low saturation target and 2015–2019 (P2) with higher target.Results: Of 630 EP infants admitted during the 10 years, 447 (71.0%) infants survived to discharge. The survival rate increased significantly from 61.6% in P1 to 75.8% in P2 (P < 0.05). Of the 472 infants who had ROP data, 318 (67.4%) developed ROP of any stage, 67 (14.2%) developed severe ROP, and 44 (9.3%) received treatment. The incidence of any ROP increased significantly from 51.7% in P1 to 74.3% in P2 (P < 0.05). The incidence of severe ROP increased from 11.0% in P1 to 15.6% in P2, and ROP treatment increased from 6.9% in P1 to 10.4% in P2, but neither reached statistical significance (both P > 0.05).Conclusions: We observed an increasing trend in the incidence of ROP across the 10-year period in one of the largest neonatal care units in China. The increased survival rate and the use of high-target oxygen saturation in the later period may partly explain this trend. Further investigations are needed to improve the care practices and to reduce the incidence of severe ROP.
- 3 September 2021
- Published by Frontiers Media SA in Frontiers in Pediatrics
- Vol. 9
Open AccessTen-Year Trend of Retinopathy of Prematurity Among Extremely Preterm Infants in One Neonatal Intensive Care Unit in China
Background: Extremely preterm (EP) infants are at the highest risk of retinopathy of prematurity (ROP). With more EP infants survived in China, recent data of ROP is lacking. The aim of the study is to report the trend of incidence of ROP among EP infants in a large neonatal intensive care unit in China over the past 10-year period, in relation with the overall survival rate and the change of oxygen saturation targets.Methods: This retrospective cohort study enrolled all EP infants born before 28 weeks' gestation and admitted to one of the largest tertiary neonatal intensive care units in China from 2010 to 2019. Data were compared between two time periods according to different oxygen saturation targets: 2010–2014 (P1) with low saturation target and 2015–2019 (P2) with higher target.Results: Of 630 EP infants admitted during the 10 years, 447 (71.0%) infants survived to discharge. The survival rate increased significantly from 61.6% in P1 to 75.8% in P2 (P < 0.05). Of the 472 infants who had ROP data, 318 (67.4%) developed ROP of any stage, 67 (14.2%) developed severe ROP, and 44 (9.3%) received treatment. The incidence of any ROP increased significantly from 51.7% in P1 to 74.3% in P2 (P < 0.05). The incidence of severe ROP increased from 11.0% in P1 to 15.6% in P2, and ROP treatment increased from 6.9% in P1 to 10.4% in P2, but neither reached statistical significance (both P > 0.05).Conclusions: We observed an increasing trend in the incidence of ROP across the 10-year period in one of the largest neonatal care units in China. The increased survival rate and the use of high-target oxygen saturation in the later period may partly explain this trend. Further investigations are needed to improve the care practices and to reduce the incidence of severe ROP.
- 1 September 2021
- Published by Wiley in Paediatric and Perinatal Epidemiology
- Vol. 36 (3) , 380-389
Incidence of retinopathy of prematurity treatment in extremely preterm infants in China
Background: Retinopathy of prematurity (ROP) continues to be a major cause of visual impairment and blindness in premature infants and children.Objectives: To investigate the incidence of severe ROP receiving treatment in extremely preterm (EP) infants in China over time. The risk factors for ROP treatment were also assessed.Methods: This was a multicentre retrospective study and a subanalysis of baseline data from the “Outcomes of EP infants in China 2010–2019” study. This study was conducted in 68 tertiary neonatal care centres from 31 provinces of China. Infants with a gestational age of 230–276 weeks and admitted to a neonatal unit within the first 72 h of life between 2010 and 2019 were enrolled. Incidence of ROP was analysed in infants who survived to 32 weeks postmenstrual age and screened for ROP. Multivariable modified Poisson regression models were used to identify risk factors for ROP treatment.Results: Among 7295 eligible infants, 4701 (64.5%) survived to 32 weeks postmenstrual age and met ROP screening criteria. Of the 3756 infants who screened and with ROP data, 2320 (61.8%) developed ROP of any stage. The overall incidence of ROP treatment was 12.6%, decreasing from 45.5% at 23 weeks to 8.3% at 27 weeks. During the 10‐year period, the incidence of ROP treatment did not change, although the incidence of any ROP increased over time. Independent risk factors associated with ROP treatment included lower gestational age, small for gestational age, multiple birth, severe intraventricular haemorrhage, patent ductus arteriosus and supplemental oxygen duration.Conclusions: The incidence of EP infants receiving ROP treatment showed no change during this 10‐year period in China. Prevention of prematurity and foetal growth restriction, judicious use of oxygen and reducing comorbidities are promising factors that may reduce the incidence of ROP needing treatment in these high‐risk infants.
- 1 September 2021
- Published by Wiley in Paediatric and Perinatal Epidemiology
- Vol. 36 (3) , 380-389
Incidence of retinopathy of prematurity treatment in extremely preterm infants in China
Background: Retinopathy of prematurity (ROP) continues to be a major cause of visual impairment and blindness in premature infants and children.Objectives: To investigate the incidence of severe ROP receiving treatment in extremely preterm (EP) infants in China over time. The risk factors for ROP treatment were also assessed.Methods: This was a multicentre retrospective study and a subanalysis of baseline data from the “Outcomes of EP infants in China 2010–2019” study. This study was conducted in 68 tertiary neonatal care centres from 31 provinces of China. Infants with a gestational age of 230–276 weeks and admitted to a neonatal unit within the first 72 h of life between 2010 and 2019 were enrolled. Incidence of ROP was analysed in infants who survived to 32 weeks postmenstrual age and screened for ROP. Multivariable modified Poisson regression models were used to identify risk factors for ROP treatment.Results: Among 7295 eligible infants, 4701 (64.5%) survived to 32 weeks postmenstrual age and met ROP screening criteria. Of the 3756 infants who screened and with ROP data, 2320 (61.8%) developed ROP of any stage. The overall incidence of ROP treatment was 12.6%, decreasing from 45.5% at 23 weeks to 8.3% at 27 weeks. During the 10‐year period, the incidence of ROP treatment did not change, although the incidence of any ROP increased over time. Independent risk factors associated with ROP treatment included lower gestational age, small for gestational age, multiple birth, severe intraventricular haemorrhage, patent ductus arteriosus and supplemental oxygen duration.Conclusions: The incidence of EP infants receiving ROP treatment showed no change during this 10‐year period in China. Prevention of prematurity and foetal growth restriction, judicious use of oxygen and reducing comorbidities are promising factors that may reduce the incidence of ROP needing treatment in these high‐risk infants.
- 26 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 32 (3) , 146-149
Laser Scanning Feedback Imaging System Based on Digital Micromirror Device
Most of the traditional scanning feedback imaging systems cannot break through the limitations of scanning speed. In this paper, a fast scanning system with changeable scanning sequences by projecting patterns alternatively on the digital micromirror device is proposed. Combined with the laser feedback techniques, the system exhibits high sensitivity to weak signals from targets with low reflectivity. In experiments, the images of handwriting ink patterns on a piece of glass are obtained in 6 seconds, and the resolution of the system is evaluated to be 124.5 lm with a 3.24mm by 3.24mm field of view. This scanning feedback imaging system can be combined potentially with single pixel imaging techniques to reconstruct phase objects more efficiently.
- 26 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 32 (3) , 146-149
Laser Scanning Feedback Imaging System Based on Digital Micromirror Device
Most of the traditional scanning feedback imaging systems cannot break through the limitations of scanning speed. In this paper, a fast scanning system with changeable scanning sequences by projecting patterns alternatively on the digital micromirror device is proposed. Combined with the laser feedback techniques, the system exhibits high sensitivity to weak signals from targets with low reflectivity. In experiments, the images of handwriting ink patterns on a piece of glass are obtained in 6 seconds, and the resolution of the system is evaluated to be 124.5 lm with a 3.24mm by 3.24mm field of view. This scanning feedback imaging system can be combined potentially with single pixel imaging techniques to reconstruct phase objects more efficiently.
- Open Access
- 1 January 2013
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 11 (10) , 90-92
Method for in situ calibration of multiple feedback interferometers
A method is presented for in situ resolution calibration of multiple feedback interferometers (MFIs) using two lasers with different feedback levels simultaneously. The laser with weak optical feedback level generates half-wavelength optical fringes, whereas the laser with strong multiple feedback level generates optical nano-fringes. By using this method, the number of displaced optical nano-fringes can be easily counted, and the resolution of the MFIs can be accurately determined. The integrated MFIs can be used to measure displacements and calibrate other displacement sensors.
- 1 January 2013
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 11 (10) , 90-92
Open AccessMethod for in situ calibration of multiple feedback interferometers
A method is presented for in situ resolution calibration of multiple feedback interferometers (MFIs) using two lasers with different feedback levels simultaneously. The laser with weak optical feedback level generates half-wavelength optical fringes, whereas the laser with strong multiple feedback level generates optical nano-fringes. By using this method, the number of displaced optical nano-fringes can be easily counted, and the resolution of the MFIs can be accurately determined. The integrated MFIs can be used to measure displacements and calibrate other displacement sensors.
- 1 February 2010
- Published by IOP Publishing in Chinese Physics B
- Vol. 19 (2) , 024206
Polarization switching in a quasi-isotropic microchip Nd:YAG laser induced by optical feedback
- 1 February 2010
- Published by IOP Publishing in Chinese Physics B
- Vol. 19 (2) , 024206
Polarization switching in a quasi-isotropic microchip Nd:YAG laser induced by optical feedback
- 1 May 2007
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 136 (2) , 567-571
Displacement self-sensing align-free He–Ne laser based on hollow cube corner prism folding cavity
- 1 May 2007
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 136 (2) , 567-571
Displacement self-sensing align-free He–Ne laser based on hollow cube corner prism folding cavity
- 1 October 2005
- Published by Taylor & Francis in Progress in Natural Science: Materials International
- Vol. 15 (10) , 865-876
Orthogonal linear polarized lasers (II)—Study on the physical phenomena
The Physical phenomena and corresponding theoretical analysis of orthogonal polarized laser are reviewed. Four lasers(or systems)with orthogonal polarized beams are involved. For the birefringence dual frequency laser, its physical phenomena discussed include the alternation between strong mode competition and medium mode competition in cavity tuning; the range of frequency difference of strong mode competition (about 0–40 MHZ); four polarization statues (o–light oscillating but e-light extinguishing, both o-light and e-light oscillating but o-light extinguishing, both o-light and e-light extinguishing)in cavity tuning; the tuning curves of frequency difference; the influence of optical activity of quartz crystal on polarization direction; and the aberrance of frequency splitting. For the birefringence–Zeeman dual frequency laser, we focus on its intensity tuning and frequency difference tuning. For the feedback system of orthogonally polarized laser, we discuss the mutual suppression between two orthogonal frequencies and double of intensity fringe frequency. For orthogonally polarized LD-pumped Nd: YAG microchip laser, its property of the dependence of intensity sensitivity on frequency difference is described.
- 1 October 2005
- Published by Taylor & Francis in Progress in Natural Science: Materials International
- Vol. 15 (10) , 865-876
Orthogonal linear polarized lasers (II)—Study on the physical phenomena
The Physical phenomena and corresponding theoretical analysis of orthogonal polarized laser are reviewed. Four lasers(or systems)with orthogonal polarized beams are involved. For the birefringence dual frequency laser, its physical phenomena discussed include the alternation between strong mode competition and medium mode competition in cavity tuning; the range of frequency difference of strong mode competition (about 0–40 MHZ); four polarization statues (o–light oscillating but e-light extinguishing, both o-light and e-light oscillating but o-light extinguishing, both o-light and e-light extinguishing)in cavity tuning; the tuning curves of frequency difference; the influence of optical activity of quartz crystal on polarization direction; and the aberrance of frequency splitting. For the birefringence–Zeeman dual frequency laser, we focus on its intensity tuning and frequency difference tuning. For the feedback system of orthogonally polarized laser, we discuss the mutual suppression between two orthogonal frequencies and double of intensity fringe frequency. For orthogonally polarized LD-pumped Nd: YAG microchip laser, its property of the dependence of intensity sensitivity on frequency difference is described.
- 27 October 2004
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 21 (11) , 2175-2178
Self-Mixing Interference in Dual-Polarization Microchip Nd:YAG Lasers
- 27 October 2004
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 21 (11) , 2175-2178
Self-Mixing Interference in Dual-Polarization Microchip Nd:YAG Lasers
- 1 October 2004
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 21 (10) , 1944-1947
Influence of Optical Feedback from Birefringence External Cavity on Intensity Tuning and Polarization of Laser
- 1 October 2004
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 21 (10) , 1944-1947
Influence of Optical Feedback from Birefringence External Cavity on Intensity Tuning and Polarization of Laser