JWJiachen Wang

Jiachen Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiachen Wang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • HabSim-HMS: A Systems Testbed to Investigate Situational Awareness for Extraterrestrial Habitation

    by R Murali Krishnan, Zixu Zhang, Kairui Hao, Sreehari Manikkan, Paul Parsons, Shirley J. Dyke, Ilias Bilionis, Jiachen Wang, Chuanyu Xue, Song Han, et al.

    Deep-space habitation presents unique challenges in operating complex control-based systems in distant and disruptive environments far from Earth. The capability to handle unforeseen situations and manage system health is crucial for resilient operations in deep space. Trusted health management strategies operational on the International Space Station (ISS) heavily rely on ground control support. These strategies must adapt to cope with sizable communication delays imposed by the infrastructure limitations or light distances that separate ground control and the habitat. Alternative approaches that increase reliance on artificial intelligence-based onboard autonomy are constrained by limited onboard computing and risks associated with human-system integration. There is an increased need to study the design and architecture of the health management system (HMS) of such complex systems to address autonomy challenges for deep-space habitation. This paper presents a model-based HMS testbed developed at the Resilient Extra-Terrestrial Habitats Institute that is part of the HabSim, a system-of-systems simulator of a smart habitat. The testbed is designed to facilitate performance assessment of critical health management functions essential to enable fault-management autonomy, situational awareness, and interface-based mission control. In this paper, the HMS testbed is motivated and placed within HabSim, the architecture of its components is detailed, and the testbed features are demonstrated through an illustrative example. The lessons learned in developing this testbed that may be useful for others seeking to solve similar problems are also discussed.


  • Open Access

    Assessing Electrocardiogram and Respiratory Signal Quality of a Wearable Device (SensEcho): Semisupervised Machine Learning-Based Validation Study

    by Haoran Xu, Wei Yan, Ke Lan, Chenbin Ma, Di Wu, Anshuo Wu, Zhicheng Yang, Jiachen Wang, Yaning Zang, Muyang Yan, et al.

    Background: With the development and promotion of wearable devices and their mobile health (mHealth) apps, physiological signals have become a research hotspot. However, noise is complex in signals obtained from daily lives, making it difficult to analyze the signals automatically and resulting in a high false alarm rate. At present, screening out the high-quality segments of the signals from huge-volume data with few labels remains a problem. Signal quality assessment (SQA) is essential and is able to advance the valuable information mining of signals. Objective: The aims of this study were to design an SQA algorithm based on the unsupervised isolation forest model to classify the signal quality into 3 grades: good, acceptable, and unacceptable; validate the algorithm on labeled data sets; and apply the algorithm on real-world data to evaluate its efficacy. Methods: Data used in this study were collected by a wearable device (SensEcho) from healthy individuals and patients. The observation windows for electrocardiogram (ECG) and respiratory signals were 10 and 30 seconds, respectively. In the experimental procedure, the unlabeled training set was used to train the models. The validation and test sets were labeled according to preset criteria and used to evaluate the classification performance quantitatively. The validation set consisted of 3460 and 2086 windows of ECG and respiratory signals, respectively, whereas the test set was made up of 4686 and 3341 windows of signals, respectively. The algorithm was also compared with self-organizing maps (SOMs) and 4 classic supervised models (logistic regression, random forest, support vector machine, and extreme gradient boosting). One case validation was illustrated to show the application effect. The algorithm was then applied to 1144 cases of ECG signals collected from patients and the detected arrhythmia false alarms were calculated. Results: The quantitative results showed that the ECG SQA model achieved 94.97% and 95.58% accuracy on the validation and test sets, respectively, whereas the respiratory SQA model achieved 81.06% and 86.20% accuracy on the validation and test sets, respectively. The algorithm was superior to SOM and achieved moderate performance when compared with the supervised models. The example case showed that the algorithm was able to correctly classify the signal quality even when there were complex pathological changes in the signals. The algorithm application results indicated that some specific types of arrhythmia false alarms such as tachycardia, atrial premature beat, and ventricular premature beat could be significantly reduced with the help of the algorithm. Conclusions: This study verified the feasibility of applying the anomaly detection unsupervised model to SQA. The application scenarios include reducing the false alarm rate of the device and selecting signal segments that can be used for further research.


  • Open Access

    Assessing Electrocardiogram and Respiratory Signal Quality of a Wearable Device (SensEcho): Semisupervised Machine Learning-Based Validation Study (Preprint)

    by Haoran Xu, Wei Yan, Ke Lan, Chenbin Ma, Di Wu, Anshuo Wu, Zhicheng Yang, Jiachen Wang, Yaning Zang, Muyang Yan, et al.

    BACKGROUND With the development and promotion of wearable devices and their mobile health (mHealth) apps, physiological signals have become a research hotspot. However, noise is complex in signals obtained from daily lives, making it difficult to analyze the signals automatically and resulting in a high false alarm rate. At present, screening out the high-quality segments of the signals from huge-volume data with few labels remains a problem. Signal quality assessment (SQA) is essential and is able to advance the valuable information mining of signals. OBJECTIVE The aims of this study were to design an SQA algorithm based on the unsupervised isolation forest model to classify the signal quality into 3 grades: good, acceptable, and unacceptable; validate the algorithm on labeled data sets; and apply the algorithm on real-world data to evaluate its efficacy. METHODS Data used in this study were collected by a wearable device (SensEcho) from healthy individuals and patients. The observation windows for electrocardiogram (ECG) and respiratory signals were 10 and 30 seconds, respectively. In the experimental procedure, the unlabeled training set was used to train the models. The validation and test sets were labeled according to preset criteria and used to evaluate the classification performance quantitatively. The validation set consisted of 3460 and 2086 windows of ECG and respiratory signals, respectively, whereas the test set was made up of 4686 and 3341 windows of signals, respectively. The algorithm was also compared with self-organizing maps (SOMs) and 4 classic supervised models (logistic regression, random forest, support vector machine, and extreme gradient boosting). One case validation was illustrated to show the application effect. The algorithm was then applied to 1144 cases of ECG signals collected from patients and the detected arrhythmia false alarms were calculated. RESULTS The quantitative results showed that the ECG SQA model achieved 94.97% and 95.58% accuracy on the validation and test sets, respectively, whereas the respiratory SQA model achieved 81.06% and 86.20% accuracy on the validation and test sets, respectively. The algorithm was superior to SOM and achieved moderate performance when compared with the supervised models. The example case showed that the algorithm was able to correctly classify the signal quality even when there were complex pathological changes in the signals. The algorithm application results indicated that some specific types of arrhythmia false alarms such as tachycardia, atrial premature beat, and ventricular premature beat could be significantly reduced with the help of the algorithm. CONCLUSIONS This study verified the feasibility of applying the anomaly detection unsupervised model to SQA. The application scenarios include reducing the false alarm rate of the device and selecting signal segments that can be used for further research.