Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Schmid has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ecoresorbable chipless temperature-responsive tag made from biodegradable materials for sustainable IoT

    by James Bourely, Nicolas Fumeaux, Xavier Aeby, Jaemin Kim, Gilberto Siqueira, Christian Beyer, David Schmid, Oleksandr Vorobyov, Gustav Nyström, Danick Briand

    Temperature monitoring within the cold chain, essential for safety of perishable products, typically employs devices such as battery-powered data loggers and radio-frequency identification tags. Such devices include non-eco-friendly components, posing challenges for their safe disposal and recycling. This study demonstrates the fabrication of a fully ecoresorbable, chipless, and wireless temperature-responsive tag, designed to irreversibly track temperature changes through a permanent shift in resonance frequency. The tag is printed on a customized moisture-resistant poly(β-hydroxybutyrate)-cellulose composite substrate. An RLC circuit made of printed zinc metallic traces, encapsulated with beeswax to prevent oxidation, enables seamless wireless operation. The tag utilizes bio-based phase-changing materials such as frozen olive, jojoba, and coconut oils to induce irreversible resonance frequency shifts of more than 30 MHz at respective melting points of 8 °C, 15 °C, and 25 °C. A cellulose capillary element efficiently absorbs the melted oil, enabling reliable operation at inclinations from 0° to 90°. At the end of its service life, the device can undergo disintegration in a compost environment within 9 weeks. This work demonstrates a sustainable chipless technology from material selection and manufacturing processes to end-of-life disposal as an advanced thermal indicator solution for cold chain temperature-excursion detection.


  • Open Access

    Ecoresorbable Radio-Frequency Platform for Humidity and Temperature Sensing

    by James Bourely, Jaemin Kim, Xavier Aeby, Gilberto Siqueira, Gustav Nyström, Oleksandr Vorobyov, Christian Beyer, David Schmid, Danick Briand

    Aiming to reduce electronic waste in sensing applications, we report on an eco-friendly printed microstrip line to sense relative humidity (RH) and temperature. The device is made of zinc resonators on paper used as transducers, which are coated with beeswax as an encapsulant, and uses konjac as a humidity sensitive coating. The multi-resonating structure, operating in the S-band, shows reproducible temperature and humidity sensing from 15 °C to 35 °C and 30% to 70% RH with sensitivities up to 1.9 MHz/°C and 2.0 MHz/%RH, respectively. This combination of transducing and sensing materials is promising for the realization of disposable environmental sensors.


  • Open Access

    Correction: Peters et al. Benchmarking the ACEnano Toolbox for Characterisation of Nanoparticle Size and Concentration by Interlaboratory Comparison. Molecules 2021, 26, 5315

    by Ruud Peters, Ingrid Elbers, Anna Undas, Eelco Sijtsma, Sophie Briffa, Pauline Carnell-Morris, Agnieszka Siupa, Tae-Hyun Yoon, Loïc Burr, David Schmid, et al.

    Due to miscommunication a number of potential co-authors were not listed in the original publication


  • Open Access

    Automation and Standardization—A Coupled Approach towards Reproducible Sample Preparation Protocols for Nanomaterial Analysis

    by Jörg Radnik, Vasile-Dan Hodoroaba, Harald Jungnickel, Jutta Tentschert, Andreas Luch, Vanessa Sogne, Florian Meier, Loïc Burr, David Schmid, Christoph Schlager, et al.

    Whereas the characterization of nanomaterials using different analytical techniques is often highly automated and standardized, the sample preparation that precedes it causes a bottleneck in nanomaterial analysis as it is performed manually. Usually, this pretreatment depends on the skills and experience of the analysts. Furthermore, adequate reporting of the sample preparation is often missing. In this overview, some solutions for techniques widely used in nano-analytics to overcome this problem are discussed. Two examples of sample preparation optimization by automation are presented, which demonstrate that this approach is leading to increased analytical confidence. Our first example is motivated by the need to exclude human bias and focuses on the development of automation in sample introduction. To this end, a robotic system has been developed, which can prepare stable and homogeneous nanomaterial suspensions amenable to a variety of well-established analytical methods, such as dynamic light scattering (DLS), small-angle X-ray scattering (SAXS), field-flow fractionation (FFF) or single-particle inductively coupled mass spectrometry (sp-ICP-MS). Our second example addresses biological samples, such as cells exposed to nanomaterials, which are still challenging for reliable analysis. An air–liquid interface has been developed for the exposure of biological samples to nanomaterial-containing aerosols. The system exposes transmission electron microscopy (TEM) grids under reproducible conditions, whilst also allowing characterization of aerosol composition with mass spectrometry. Such an approach enables correlative measurements combining biological with physicochemical analysis. These case studies demonstrate that standardization and automation of sample preparation setups, combined with appropriate measurement processes and data reduction are crucial steps towards more reliable and reproducible data.


  • Open Access

    Benchmarking the ACEnano Toolbox for Characterisation of Nanoparticle Size and Concentration by Interlaboratory Comparisons

    by Ruud Peters, Ingrid Elbers, Anna Undas, Eelco Sijtsma, Sophie Briffa, Pauline Carnell-Morris, Agnieszka Siupa, Tae-Hyun Yoon, Loïc Burr, David Schmid, et al.

    ACEnano is an EU-funded project which aims at developing, optimising and validating methods for the detection and characterisation of nanomaterials (NMs) in increasingly complex matrices to improve confidence in the results and support their use in regulation. Within this project, several interlaboratory comparisons (ILCs) for the determination of particle size and concentration have been organised to benchmark existing analytical methods. In this paper the results of a number of these ILCs for the characterisation of NMs are presented and discussed. The results of the analyses of pristine well-defined particles such as 60 nm Au NMs in a simple aqueous suspension showed that laboratories are well capable of determining the sizes of these particles. The analysis of particles in complex matrices or formulations such as consumer products resulted in larger variations in particle sizes within technologies and clear differences in capability between techniques. Sunscreen lotion sample analysis by laboratories using spICP-MS and TEM/SEM identified and confirmed the TiO2 particles as being nanoscale and compliant with the EU definition of an NM for regulatory purposes. In a toothpaste sample orthogonal results by PTA, spICP-MS and TEM/SEM agreed and stated the TiO2 particles as not fitting the EU definition of an NM. In general, from the results of these ILCs we conclude that laboratories are well capable of determining particle sizes of NM, even in fairly complex formulations.


  • Open Access

    Towards a method for quantitative evaluation of nanoparticle from suspensions via microarray printing and SEM analysis

    by F Bennet, L Burr, D Schmid, V-D Hodoroaba

    As part of the development of a library of accurate and efficient methods for measurement of nanoparticle properties, we develop and optimize a method for the efficient analysis of nanoparticle size distribution from suspensions via microprinting and digital analysis of electron microscopy (SEM and TEM) images, with the ultimate aim of automated quantitative concentration analysis (calculated from drop volume). A series of different nanoparticle suspensions (gold, latex, and SiO2 in varying sizes and concentrations) were printed onto TEM grids in a 4 x 4 array in the concentration range 7×108 to 1×1011 nanoparticles/mL and imaged with SEM. Concentrations and printing conditions (temperature, relative humidity) were varied in order to minimize the coffee-ring effect.