Payam Mohammadinejad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Payam Mohammadinejad has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Cynthia H. McCollough
Department of Radiology, Mayo Clinic, Rochester, Minnesota
2 shared publications - Joel G. Fletcher
Department of Radiology, Mayo Clinic, Rochester, USA
2 shared publications - Achille Mileto
Department of Radiology, University of Washington, Seattle, USA
1 shared publication - Adam T. Froemming
Department of Radiology, Mayo Clinic Rochester, Rochester, Minn
1 shared publication Ahmad Khodadad
Pediatrics Center of Excellence, Children's Medical Center, Tehran University of Medical Sciences, Tehran, Iran
1 shared publicationAhmed F Halaweish
Siemens Medical Solutions, USA
1 shared publication
Latest Publications
- 1 September 2021
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 41 (5) , 1493-1508
CT Noise-Reduction Methods for Lower-Dose Scanning: Strengths and Weaknesses of Iterative Reconstruction Algorithms and New Techniques
In pursuit of lower-radiation-dose CT, radiologists should be aware of the strengths, weaknesses, and methods of assessment of iterative reconstruction algorithms, as well as new image reconstructi... Iterative reconstruction (IR) algorithms are the most widely used CT noise-reduction method to improve image quality and have greatly facilitated radiation dose reduction within the radiology commu...
- 1 September 2021
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 41 (5) , 1493-1508
CT Noise-Reduction Methods for Lower-Dose Scanning: Strengths and Weaknesses of Iterative Reconstruction Algorithms and New Techniques
In pursuit of lower-radiation-dose CT, radiologists should be aware of the strengths, weaknesses, and methods of assessment of iterative reconstruction algorithms, as well as new image reconstructi... Iterative reconstruction (IR) algorithms are the most widely used CT noise-reduction method to improve image quality and have greatly facilitated radiation dose reduction within the radiology commu...
- Open Access
- 27 July 2021
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 10 (7)
The utility of a dual-phase, dual-energy CT protocol in patients presenting with overt gastrointestinal bleeding
Due to their easy accessibility, CT scans have been increasingly used for investigation of gastrointestinal (GI) bleeding. To estimate the performance of a dual-phase, dual-energy (DE) GI bleed CT protocol in patients with overt GI bleeding in clinical practice and examine the added value of portal phase and DE images. Consecutive patients with GI bleeding underwent a two-phase DE GI bleed CT protocol. Two gastroenterologists established the reference standard. Performance was estimated using clinical CT reports. Three GI radiologists rated confidence in GI bleeding in a subset of 62 examinations, evaluating first mixed kV arterial images, then after examining additional portal venous phase images, and finally after additional DE images (virtual non-contrast and virtual monoenergetic 50 keV images). 52 of 176 patients (29.5%) had GI bleeding by the reference standard. The overall sensitivity, specificity, and positive and negative predictive values of the CT GI bleed protocol for detecting GI bleeding were 65.4%, 89.5%, 72.3%, and 86.0%, respectively. In patients with GI bleeding, diagnostic confidence of readers increased after adding portal phase images to arterial phase images (p = 0.002), without additional benefit from dual energy images. In patients without GI bleeding, confidence in luminal extravasation appropriately decreased after adding portal phase, and subsequently DE images (p = 0.006, p = 0.018). A two-phase DE GI bleed CT protocol had high specificity and negative predictive value in clinical practice. Portal venous phase images improved diagnostic confidence in comparison to arterial phase images alone. Dual-energy images further improved radiologist confidence in the absence of bleeding.
- 27 July 2021
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 10 (7)
Open AccessThe utility of a dual-phase, dual-energy CT protocol in patients presenting with overt gastrointestinal bleeding
Due to their easy accessibility, CT scans have been increasingly used for investigation of gastrointestinal (GI) bleeding. To estimate the performance of a dual-phase, dual-energy (DE) GI bleed CT protocol in patients with overt GI bleeding in clinical practice and examine the added value of portal phase and DE images. Consecutive patients with GI bleeding underwent a two-phase DE GI bleed CT protocol. Two gastroenterologists established the reference standard. Performance was estimated using clinical CT reports. Three GI radiologists rated confidence in GI bleeding in a subset of 62 examinations, evaluating first mixed kV arterial images, then after examining additional portal venous phase images, and finally after additional DE images (virtual non-contrast and virtual monoenergetic 50 keV images). 52 of 176 patients (29.5%) had GI bleeding by the reference standard. The overall sensitivity, specificity, and positive and negative predictive values of the CT GI bleed protocol for detecting GI bleeding were 65.4%, 89.5%, 72.3%, and 86.0%, respectively. In patients with GI bleeding, diagnostic confidence of readers increased after adding portal phase images to arterial phase images (p = 0.002), without additional benefit from dual energy images. In patients without GI bleeding, confidence in luminal extravasation appropriately decreased after adding portal phase, and subsequently DE images (p = 0.006, p = 0.018). A two-phase DE GI bleed CT protocol had high specificity and negative predictive value in clinical practice. Portal venous phase images improved diagnostic confidence in comparison to arterial phase images alone. Dual-energy images further improved radiologist confidence in the absence of bleeding.
- 1 October 2015
- Published by Springer Nature in Obesity Surgery
- Vol. 25 (12) , 2426-2427
A Comment on “Obesity Surgery and Ramadan: a Prospective Analysis of Nutritional Intake, Hunger and Satiety and Adaptive Behaviours During Fasting”
- 1 October 2015
- Published by Springer Nature in Obesity Surgery
- Vol. 25 (12) , 2426-2427
A Comment on “Obesity Surgery and Ramadan: a Prospective Analysis of Nutritional Intake, Hunger and Satiety and Adaptive Behaviours During Fasting”
- Open Access
- 15 January 2014
- Published by The Editorial Office of Gut and Liver in Gut and Liver
- Vol. 8 (1) , 24-28
Evaluation of Antibody Response to Polysaccharide Vaccine and Switched Memory B Cells in Pediatric Patients with Inflammatory Bowel Disease
Inflammatory bowel disease (IBD) is a chronic disease of the gastrointestinal tract, whose etiologies are still unknown. This study was performed to evaluate the humoral immune response in terms of B cell functions in selected IBD patients. Eighteen pediatric patients with IBD, including 12 cases of ulcerative colitis (UC) and six with Crohn disease (CD), were enrolled in this study. The pneumococcal vaccine was injected in all patients, and the IgG antibody level to the polysaccharide antigen was measured before and 4 weeks after injection. The B cell switch-recombination process was evaluated. Five patients with IBD (three CD and two UC) had defects in B cell switching, which was significantly higher than in controls (p=0.05). Ten patients had a specific antibody deficiency and exhibited a higher frequency of bacterial infection than the healthy group. The mean increased level of IgG after vaccination was lower in IBD patients (82.9±32.5 µg/mL vs 219.8±59.0 µg/mL; p=0.001). Among the patients who had an insufficient response, no significant difference in the number of switched memory B-cell was observed. A defect in B lymphocyte switching was observed in pediatric IBD patients, and especially in those patients with CD. Owing to an increased risk of bacterial infections in those patients with antibody production defects, pneumococcal vaccination could be recommended. However, not all patients can benefit from the vaccination, and several may require other prophylactic methods.
- 15 January 2014
- Published by The Editorial Office of Gut and Liver in Gut and Liver
- Vol. 8 (1) , 24-28
Open AccessEvaluation of Antibody Response to Polysaccharide Vaccine and Switched Memory B Cells in Pediatric Patients with Inflammatory Bowel Disease
Inflammatory bowel disease (IBD) is a chronic disease of the gastrointestinal tract, whose etiologies are still unknown. This study was performed to evaluate the humoral immune response in terms of B cell functions in selected IBD patients. Eighteen pediatric patients with IBD, including 12 cases of ulcerative colitis (UC) and six with Crohn disease (CD), were enrolled in this study. The pneumococcal vaccine was injected in all patients, and the IgG antibody level to the polysaccharide antigen was measured before and 4 weeks after injection. The B cell switch-recombination process was evaluated. Five patients with IBD (three CD and two UC) had defects in B cell switching, which was significantly higher than in controls (p=0.05). Ten patients had a specific antibody deficiency and exhibited a higher frequency of bacterial infection than the healthy group. The mean increased level of IgG after vaccination was lower in IBD patients (82.9±32.5 µg/mL vs 219.8±59.0 µg/mL; p=0.001). Among the patients who had an insufficient response, no significant difference in the number of switched memory B-cell was observed. A defect in B lymphocyte switching was observed in pediatric IBD patients, and especially in those patients with CD. Owing to an increased risk of bacterial infections in those patients with antibody production defects, pneumococcal vaccination could be recommended. However, not all patients can benefit from the vaccination, and several may require other prophylactic methods.