Ludovica Pieroni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ludovica Pieroni has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Freddi
University College London
5 shared publications - Andre R. Barbosa
Oregon State University
4 shared publications - Massimo Latour
University of Salerno
4 shared publications - Barbara Simpson
Stanford University
3 shared publications - Sabatino Di Benedetto
University of Salerno
3 shared publications - Ali Roumieh
University College London
2 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by Springer Nature
- p. 711-723
Advancing Seismic Resilience of Self-centring Steel MRFs: From Component Testing to Large-Scale Shake Table Testing
- 17 November 2026
- Published by Springer Nature
- p. 711-723
Open AccessAdvancing Seismic Resilience of Self-centring Steel MRFs: From Component Testing to Large-Scale Shake Table Testing
- 1 September 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 152 (9)
Design and Shake-Table Testing of a Full-Scale, Six-Story Mass Timber Building with Posttensioned Rocking Walls and Buckling-Restrained Boundary Elements
Although dynamic contributions from higher modes are known to influence the force demands in mass timber rocking walls, higher-mode force and acceleration demands have not been formally addressed in a design procedure incorporating limit states at multiple intensity levels. This study assessed the design and dynamic response of posttensioned (PT) mass ply panel (MPP) rocking walls with buckling-restrained boundary elements (BRBs), referred to as MPP-BRB walls. A design approach using multiple modes to estimate system-level dynamic demands was adopted for the design of MPP-BRB walls and assessed via shake-table testing of a full-scale, six-story, mass timber building at the National Hazards Engineering Research Infrastructure (NHERI) Large High-Performance Outdoor Shake Table (LHPOST6) at the University of California, San Diego (UCSD). To meet global and local performance criteria at service, design, and risk-targeted maximum considered earthquake ( MCE R ) seismic intensity levels, the test specimen was designed using a modal combination rule, which assumes the higher modes superimpose with a first mode governing the nonlinear response. The modal combination rule was validated through comparison of modal estimates for peak response derived using the test specimen’s modal properties identified in white-noise testing and measured story drift, story force, and floor acceleration demands. The testing program utilized ground motion records scaled to the MCE R design spectrum for a hypothetical Seattle site, where ground motions were chosen to demonstrate the potential for higher-mode effects in the rocking system. After 18 tests with ground motion intensities ranging from 10% MCE R to 110% MCE R , the building exhibited negligible observable residual drifts. The MPP-BRB system behaved as intended, with the rocking wall enforcing a near-uniform distribution of story drift and the posttensioning enabling recentering. The design approach was able to represent the distribution and peak values of the experimentally observed responses, including posttensioning force stability, wall uplift, story drifts, floor accelerations, and force demands.
- 1 September 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 152 (9)
Design and Shake-Table Testing of a Full-Scale, Six-Story Mass Timber Building with Posttensioned Rocking Walls and Buckling-Restrained Boundary Elements
Although dynamic contributions from higher modes are known to influence the force demands in mass timber rocking walls, higher-mode force and acceleration demands have not been formally addressed in a design procedure incorporating limit states at multiple intensity levels. This study assessed the design and dynamic response of posttensioned (PT) mass ply panel (MPP) rocking walls with buckling-restrained boundary elements (BRBs), referred to as MPP-BRB walls. A design approach using multiple modes to estimate system-level dynamic demands was adopted for the design of MPP-BRB walls and assessed via shake-table testing of a full-scale, six-story, mass timber building at the National Hazards Engineering Research Infrastructure (NHERI) Large High-Performance Outdoor Shake Table (LHPOST6) at the University of California, San Diego (UCSD). To meet global and local performance criteria at service, design, and risk-targeted maximum considered earthquake ( MCE R ) seismic intensity levels, the test specimen was designed using a modal combination rule, which assumes the higher modes superimpose with a first mode governing the nonlinear response. The modal combination rule was validated through comparison of modal estimates for peak response derived using the test specimen’s modal properties identified in white-noise testing and measured story drift, story force, and floor acceleration demands. The testing program utilized ground motion records scaled to the MCE R design spectrum for a hypothetical Seattle site, where ground motions were chosen to demonstrate the potential for higher-mode effects in the rocking system. After 18 tests with ground motion intensities ranging from 10% MCE R to 110% MCE R , the building exhibited negligible observable residual drifts. The MPP-BRB system behaved as intended, with the rocking wall enforcing a near-uniform distribution of story drift and the posttensioning enabling recentering. The design approach was able to represent the distribution and peak values of the experimentally observed responses, including posttensioning force stability, wall uplift, story drifts, floor accelerations, and force demands.
- Open Access
- 31 July 2025
- Published by Springer Nature
- p. 243-254
Design and Analysis of Large-Scale Tests of a Self-centring Seismic-Resilient Steel MRF
Conventional seismic design methods rely on structural inelastic hysteretic response to dissipate seismic energy. This approach often results in extensive damage and substantial direct and indirect losses following high-intensity earthquakes, thereby affecting the overall resilience of communities. To address this issue, modern earthquake engineering is facing an extraordinarily challenging era in providing affordable, high-seismic-performance structures able to minimise both seismic damage and repair time. To this end, the ERIES SC-RESTEEL (Self-Centring seismic-RESilient sTEEL structures) project examines the structural response, repairability, resilience, and performance recovery of low-damage self-centring steel Moment-Resisting Frames (MRFs) equipped with friction devices and post-tensioned bars with disc springs at column bases and beam-to-column joints. Shaking table tests will be conducted at LNEC (Laboratório Nacional de Engenharia Civil) in Lisbon, Portugal, to investigate the performance of a large-scale 3-storey steel MRF. Key objectives include evaluating the seismic performance of the structure, its reparability strategy, and the performance after repairs. This paper presents the test specimen design, advanced Finite Element analyses of various joint configurations, and the preparatory work for the tests. The findings offer valuable insights into the expected experimental outcomes.
- 31 July 2025
- Published by Springer Nature
- p. 243-254
Open AccessDesign and Analysis of Large-Scale Tests of a Self-centring Seismic-Resilient Steel MRF
Conventional seismic design methods rely on structural inelastic hysteretic response to dissipate seismic energy. This approach often results in extensive damage and substantial direct and indirect losses following high-intensity earthquakes, thereby affecting the overall resilience of communities. To address this issue, modern earthquake engineering is facing an extraordinarily challenging era in providing affordable, high-seismic-performance structures able to minimise both seismic damage and repair time. To this end, the ERIES SC-RESTEEL (Self-Centring seismic-RESilient sTEEL structures) project examines the structural response, repairability, resilience, and performance recovery of low-damage self-centring steel Moment-Resisting Frames (MRFs) equipped with friction devices and post-tensioned bars with disc springs at column bases and beam-to-column joints. Shaking table tests will be conducted at LNEC (Laboratório Nacional de Engenharia Civil) in Lisbon, Portugal, to investigate the performance of a large-scale 3-storey steel MRF. Key objectives include evaluating the seismic performance of the structure, its reparability strategy, and the performance after repairs. This paper presents the test specimen design, advanced Finite Element analyses of various joint configurations, and the preparatory work for the tests. The findings offer valuable insights into the expected experimental outcomes.
- Open Access
- 17 August 2022
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 197, 107489
Genetic Algorithm for the optimal placement of Self-Centering Damage-Free joints in steel MRFs
- 17 August 2022
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 197, 107489
Open AccessGenetic Algorithm for the optimal placement of Self-Centering Damage-Free joints in steel MRFs
- Open Access
- 14 February 2022
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 51 (5) , 1292-1316
Effective placement of self‐centering damage‐free connections for seismic‐resilient steel moment resisting frames
In recent years, significant advancements have been made in the definition of innovative “minimal‐damage structures,” chasing the need for more resilient societies against extreme seismic events. In this context, moment resisting frames (MRFs) equipped with self‐centering damage‐free (SCDF) devices in column bases and beam‐to‐column joints represent a viable solution to improve structural resilience and damage reduction. However, the extensive use of these devices significantly increases complexity and costs compared to conventional structures, thus limiting their practical application. To overcome this drawback, current research works are focusing on the definition of effective placement for SCDF devices, maximizing their beneficial effect on the seismic response and controlling their impact on the overall structural complexity. Within this context, the present study investigates the influence of the placement of SCDF devices in a steel MRF. An eight‐story MRF is designed, and 50 configurations with different locations of SCDF joints are considered. Numerical models are developed in OpenSees, and non‐linear static push–pull and incremental dynamic analyses (IDAs) are carried out. The influence of the placement of SCDF devices is assessed by considering residual and peak interstory drifts, residual top story drifts, peak story accelerations, and the total dissipated energy as performance parameters. The results of IDAs for a seismic intensity corresponding to the ultimate limit state (ULS) are analyzed and compared, and fragility curves are successively derived for some relevant configurations. The paper provides insights and observations to understand how including a different number of SCDF BCJs at different stories affects the seismic response.
- 14 February 2022
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 51 (5) , 1292-1316
Open AccessEffective placement of self‐centering damage‐free connections for seismic‐resilient steel moment resisting frames
In recent years, significant advancements have been made in the definition of innovative “minimal‐damage structures,” chasing the need for more resilient societies against extreme seismic events. In this context, moment resisting frames (MRFs) equipped with self‐centering damage‐free (SCDF) devices in column bases and beam‐to‐column joints represent a viable solution to improve structural resilience and damage reduction. However, the extensive use of these devices significantly increases complexity and costs compared to conventional structures, thus limiting their practical application. To overcome this drawback, current research works are focusing on the definition of effective placement for SCDF devices, maximizing their beneficial effect on the seismic response and controlling their impact on the overall structural complexity. Within this context, the present study investigates the influence of the placement of SCDF devices in a steel MRF. An eight‐story MRF is designed, and 50 configurations with different locations of SCDF joints are considered. Numerical models are developed in OpenSees, and non‐linear static push–pull and incremental dynamic analyses (IDAs) are carried out. The influence of the placement of SCDF devices is assessed by considering residual and peak interstory drifts, residual top story drifts, peak story accelerations, and the total dissipated energy as performance parameters. The results of IDAs for a seismic intensity corresponding to the ultimate limit state (ULS) are analyzed and compared, and fragility curves are successively derived for some relevant configurations. The paper provides insights and observations to understand how including a different number of SCDF BCJs at different stories affects the seismic response.