Maria Anagnostou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria Anagnostou has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
A. Potamianou
Department of Microbiology, Asklipio General Hospital of Voula, Athens, Greece
1 shared publicationAfrodite Kakaboura
Department of Operative Dentistry, School of Dentistry, University of Athens, 2 Thivon Str., 11527 Goudi, Athens, Greece
1 shared publication- Anastasia Zappi
Department of Operative Dentistry, School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece
1 shared publication C. Tesseromatis
Department of Pharmacology, Medical School, University of Athens, 75 Mikras Asias St., Goudi, Athens 11527, Greece
1 shared publication- Charikleia Paximada
Department of Operative Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece
1 shared publication - Christina Papadopoulou
Independent Researcher, 11527 Athens, Greece
1 shared publication
Latest Publications
- Open Access
- 22 May 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (5) , 139
Is a Wiggling-Motion Modified Two-Step Impression Technique as Accurate as Conventional Techniques in Restorative Dentistry?
Background: The purpose of this study was to evaluate dental impression accuracy of one-step and two-step techniques compared to a modified two-step technique. Methods: Four impression techniques were compared: (1) a one-step double mix (DM) technique, (2) a cut-out (CO) technique, in which space relief was created using a blade and a laboratory bur, (3) a membrane (ME) technique, in which space relief was created by placing a PVC membrane on top of the putty material during the primary impression, and (4) a wiggling motion (WI) technique, in which PVC membrane was placed and additional wiggling movements were performed during the first 20 s when the primary impression was seated upon the master model (MM). Impressions were poured with type IV stone. Casts were scanned with a laboratory scanner and measurements were made for each cast using three-dimensional analysis software. Results: All groups presented differences compared to MM group, in at least one intra-abutment distance. Groups DM and ME presented the most significant differences, in three and two distances, respectively, whereas CO and WI presented one significant different distance compared to MM. There were no differences between MM and the four techniques for inter-abutment distances. Conclusions: WI yielded similar results with CO technique. Both performed better than the other groups.
- 22 May 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (5) , 139
Open AccessIs a Wiggling-Motion Modified Two-Step Impression Technique as Accurate as Conventional Techniques in Restorative Dentistry?
Background: The purpose of this study was to evaluate dental impression accuracy of one-step and two-step techniques compared to a modified two-step technique. Methods: Four impression techniques were compared: (1) a one-step double mix (DM) technique, (2) a cut-out (CO) technique, in which space relief was created using a blade and a laboratory bur, (3) a membrane (ME) technique, in which space relief was created by placing a PVC membrane on top of the putty material during the primary impression, and (4) a wiggling motion (WI) technique, in which PVC membrane was placed and additional wiggling movements were performed during the first 20 s when the primary impression was seated upon the master model (MM). Impressions were poured with type IV stone. Casts were scanned with a laboratory scanner and measurements were made for each cast using three-dimensional analysis software. Results: All groups presented differences compared to MM group, in at least one intra-abutment distance. Groups DM and ME presented the most significant differences, in three and two distances, respectively, whereas CO and WI presented one significant different distance compared to MM. There were no differences between MM and the four techniques for inter-abutment distances. Conclusions: WI yielded similar results with CO technique. Both performed better than the other groups.
- Open Access
- 8 May 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (5) , 128
Does Sterilization Affect the Performance of Single-Step Resin Composite Polishers?
(1) Background: Single-step polishers are used extensively for resin-composite polishing. The purpose of this study was to evaluate the effect of sterilization on their performance. (2) Methods: Optrapol Next Generation/Ivoclar-Vivadent, Jazz Supreme/SS White, Optishine Brush/Kerr and Jiffy Polishing Brush/Ultradent were used for polishing a nanohybrid resin composite (IPS Empress Direct/Ivoclar-Vivadent). Polishers (n = 40) were microscopically inspected before use. After polishing, surface roughness (Sa, Sz, Sdr, Sci) and gloss were determined. Polishers were subsequently sterilized and microscopically re-examined. The process was repeated four times on new samples (n = 200). Data were analyzed using the Friedman test and Wilcoxon post hoc test, at α = 0.05. (3) Results: Optrapol’s performance improved after the first sterilization for Sa and gloss, whereas it declined after the fourth sterilization for Sa. Jazz’s, improved after the second sterilization for Sa and gloss and after the third sterilization for Sdr. An improvement trend was observed for Optishine after the first sterilization, but not statistically significant. Sa, Sz, and gloss declined after the fourth sterilization. Jiffy’s performance was inconsistent, with a trend of performance loss after the fourth sterilization. (4) Conclusions: Performance of all polishing systems improved after the initial sterilization, but deteriorated after the fourth sterilization cycle. However, their performance can be considered clinically acceptable for a longer period of use.
- 8 May 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (5) , 128
Open AccessDoes Sterilization Affect the Performance of Single-Step Resin Composite Polishers?
(1) Background: Single-step polishers are used extensively for resin-composite polishing. The purpose of this study was to evaluate the effect of sterilization on their performance. (2) Methods: Optrapol Next Generation/Ivoclar-Vivadent, Jazz Supreme/SS White, Optishine Brush/Kerr and Jiffy Polishing Brush/Ultradent were used for polishing a nanohybrid resin composite (IPS Empress Direct/Ivoclar-Vivadent). Polishers (n = 40) were microscopically inspected before use. After polishing, surface roughness (Sa, Sz, Sdr, Sci) and gloss were determined. Polishers were subsequently sterilized and microscopically re-examined. The process was repeated four times on new samples (n = 200). Data were analyzed using the Friedman test and Wilcoxon post hoc test, at α = 0.05. (3) Results: Optrapol’s performance improved after the first sterilization for Sa and gloss, whereas it declined after the fourth sterilization for Sa. Jazz’s, improved after the second sterilization for Sa and gloss and after the third sterilization for Sdr. An improvement trend was observed for Optishine after the first sterilization, but not statistically significant. Sa, Sz, and gloss declined after the fourth sterilization. Jiffy’s performance was inconsistent, with a trend of performance loss after the fourth sterilization. (4) Conclusions: Performance of all polishing systems improved after the initial sterilization, but deteriorated after the fourth sterilization cycle. However, their performance can be considered clinically acceptable for a longer period of use.
- 1 January 2010
- Published by Elsevier in Journal of Dentistry
- Vol. 38, e129-e136
Effect of tooth-bleaching methods on gloss and color of resin composites
- 1 January 2010
- Published by Elsevier in Journal of Dentistry
- Vol. 38, e129-e136
Effect of tooth-bleaching methods on gloss and color of resin composites
- 1 July 2009
- Published by Elsevier in Dental Materials
- Vol. 25 (7) , 863-867
Biocompatibility of resin composites subcutaneously implanted in rats with experimentally induced arthritis
- 1 July 2009
- Published by Elsevier in Dental Materials
- Vol. 25 (7) , 863-867
Biocompatibility of resin composites subcutaneously implanted in rats with experimentally induced arthritis