    Device based monitoring in digital care and its impact on hospital service use

    by Anne-Jet S. Jansen, Guido M. Peters, Laura Kooij, Carine J. M. Doggen, Wim H. van Harten

    This systematic review examines four themes of device-based remote monitoring (DRM): technology, patient monitoring and support, integration of DRM into clinical care, and patient engagement, and their impact on hospital service use. We included randomized controlled trials (RCTs) until 2024 comparing hospital service use in DRM with usual care. Hospital service use decreased in DRM in 72% of the 116 included RCTs. Non-implantable devices were most commonly used to measure data, but showed a lower decrease in hospital service use than implanted or mobile devices (69% vs 89% and 76%). Providing 24/7 support for patients led to a decrease (81% of the studies). DRM replacing usual care, involving designated healthcare providers, and patient-performed data transmission led to a greater decrease in hospital service use. DRM has the potential to further reduce hospital service use with additional factors such as sufficient support, automated processes, and optimized care redesign.


  • Open Access

    Technological Aspects of Device-Based Monitoring and the Impact on Hospital Services

    by Anne-Jet Jansen, Guido Peters, Laura Kooij, Carine Doggen, Wim van Harten

    This systematic review examines the components of technology used in device-based monitoring and its impact on hospital service use. The most impactful remote monitoring interventions were those measuring vital signs and behavior, while non-implantable devices had less impact on hospital service use.

  • Open Access

    Budget impact analysis of providing hospital inpatient care at home virtually, starting with two specific surgical patient groups

    by Guido M Peters, Carine J M Doggen, Wim H van Harten

    Objective To determine the budget impact of virtual care. Methods We conducted a budget impact analysis of virtual care from the perspective of a large teaching hospital in the Netherlands. Virtual care included remote monitoring of vital signs and three daily remote contacts. Net budget impact over 5 years and net costs per patient per day (costs/patient/day) were calculated for different scenarios: implementation in one ward, in two different wards, in the entire hospital, and in multiple hospitals. Sensitivity analyses included best-case and worst-case scenarios, and reducing the frequency of daily remote contacts. Results Net budget impact over 5 years was €2 090 000 for implementation in one ward, €410 000 for two wards and €−6 206 000 for the entire hospital. Costs/patient/day in the first year were €303 for implementation in one ward, €94 for two wards and €11 for the entire hospital, decreasing in subsequent years to a mean of €259 (SD=€72), €17 (SD=€10) and €−55 (SD=€44), respectively. Projecting implementation in every Dutch hospital resulted in a net budget impact over 5 years of €−445 698 500. For this scenario, costs/patient/day decreased to €−37 in the first year, and to €54 in subsequent years in the base case. Conclusions With present cost levels, virtual care only saves money if it is deployed at sufficient scale or if it can be designed such that the active involvement of health professionals is minimised. Taking a greenfield approach, involving larger numbers of hospitals, further decreases costs compared with implementing virtual care in one hospital alone.


  • Open Access

    Remote continuous monitoring with wireless wearable sensors in clinical practice, nurses perspectives on factors affecting implementation: a qualitative study

    by Laura Kooij, Guido M. Peters, Carine J. M. Doggen, Wim H. van Harten

    Background: Continuous monitoring using wireless wearable sensors is a promising solution for use in clinical practice and in the home setting. It is important to involve nurses to ensure successful implementation. This paper aims to provide an overview of 1) factors affecting implementation of continuous monitoring using wireless wearable sensors by evaluating nurses’ experiences with its use on the nursing ward, and 2) nurses’ expectations for use in the home setting. Methods: Semi-structured interviews were conducted with 16 nurses from three teaching hospitals in the Netherlands, covering constructs from the Consolidated Framework for Implementation Research (CFIR). A deductive approach of directed content analysis was applied. One additional factor was added using the Unified Theory for Acceptance of Technology (UTAUT). The quotes and domains were rated on valence (positive, neutral, negative) and strength (strong: − 2, + 2, neutral 0, and weak: − 1, + 1). Results: Data was collected on 27 CFIR constructs and 1 UTAUT construct. In the experience of at least 8 nurses, five constructs had a strong positive influence on implementation on the nursing ward, including relative advantage (e.g., early detection of deterioration), patient needs and resources (e.g. feeling safe), networks and communications (e.g. execute tasks together), personal attributes (e.g. experience with intervention), and implementation leaders (e.g., project leader). Five constructs had a strong negative influence: evidence strength and quality (e.g. lack of evidence from practical experience), complexity (e.g. number of process steps), design quality and packaging (e.g., bad sensor quality), compatibility (e.g, change in work) and facilitating conditions (e.g, Wi-Fi connection). Nurses expected continuous monitoring in the home setting to be hindered by compatibility with work processes and to be facilitated by staff’s access to information. Technical facilitating conditions (e.g. interoperability) were suggested to be beneficial for further development. Conclusions: This paper provides an overview, of factors influencing implementation of continuous monitoring including relative importance, based on nurses’ experiences with use on nursing wards, and their perspectives for use in the home setting. Implementation of continuous monitoring is affected by a wide range of factors. This overview may be used as a guideline for future implementations.


  • Open Access

    Continuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting

    by Niels Kant, Guido M. Peters, Brenda J. Voorthuis, Catharina G. M. Groothuis-Oudshoorn, Mark V. Koning, Bart P. L. Witteman, Myra Rinia-Feenstra, Carine J. M. Doggen

    Our aim was to determine the agreement of heart rate (HR) and respiratory rate (RR) measurements by the Philips Biosensor with a reference monitor (General Electric Carescape B650) in severely obese patients during and after bariatric surgery. Additionally, sensor reliability was assessed. Ninety-four severely obese patients were monitored with both the Biosensor and reference monitor during and after bariatric surgery. Agreement was defined as the mean absolute difference between both monitoring devices. Bland Altman plots and Clarke Error Grid analysis (CEG) were used to visualise differences. Sensor reliability was reflected by the amount, duration and causes of data loss. The mean absolute difference for HR was 1.26 beats per minute (bpm) (SD 0.84) during surgery and 1.84 bpm (SD 1.22) during recovery, and never exceeded the 8 bpm limit of agreement. The mean absolute difference for RR was 1.78 breaths per minute (brpm) (SD 1.90) during surgery and 4.24 brpm (SD 2.75) during recovery. The Biosensor’s RR measurements exceeded the 2 brpm limit of agreement in 58% of the compared measurements. Averaging 15 min of measurements for both devices improved agreement. CEG showed that 99% of averaged RR measurements resulted in adequate treatment. Data loss was limited to 4.5% of the total duration of measurements for RR. No clear causes for data loss were found. The Biosensor is suitable for remote monitoring of HR, but not RR in morbidly obese patients. Future research should focus on improving RR measurements, the interpretation of continuous data, and development of smart alarm systems.


  • Open Access

    The Effect of Telehealth on Hospital Services Use: Systematic Review and Meta-analysis

    by Guido M Peters, Laura Kooij, Anke Lenferink, Wim H van Harten, Carine J M Doggen

    Background: Telehealth interventions, that is, health care provided over a distance using information and communication technology, are suggested as a solution to rising health care costs by reducing hospital service use. However, the extent to which this is possible is unclear. Objective: The aim of this study is to evaluate the effect of telehealth on the use of hospital services, that is, (duration of) hospitalizations, and to compare the effects between telehealth types and health conditions. Methods: We searched PubMed, Scopus, and the Cochrane Library from inception until April 2019. Peer-reviewed randomized controlled trials (RCTs) reporting the effect of telehealth interventions on hospital service use compared with usual care were included. Risk of bias was assessed using the Cochrane Risk of Bias 2 tool and quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation guidelines. Results: We included 127 RCTs in the meta-analysis. Of these RCTs, 82.7% (105/127) had a low risk of bias or some concerns overall. High-quality evidence shows that telehealth reduces the risk of all-cause or condition-related hospitalization by 18 (95% CI 0-30) and 37 (95% CI 20-60) per 1000 patients, respectively. We found high-quality evidence that telehealth leads to reductions in the mean all-cause and condition-related hospitalizations, with 50 and 110 fewer hospitalizations per 1000 patients, respectively. Overall, the all-cause hospital days decreased by 1.07 (95% CI −1.76 to −0.39) days per patient. For hospitalized patients, the mean hospital stay for condition-related hospitalizations decreased by 0.89 (95% CI −1.42 to −0.36) days. The effects were similar between telehealth types and health conditions. A trend was observed for studies with longer follow-up periods yielding larger effects. Conclusions: Small to moderate reductions in hospital service use can be achieved using telehealth. It should be noted that, despite the large number of included studies, uncertainties around the magnitude of effects remain, and not all effects are statistically significant.


  • Open Access

    The Effect of Telehealth on Hospital Services Use: Systematic Review and Meta-analysis (Preprint)

    by Guido M Peters, Laura Kooij, Anke Lenferink, Wim H van Harten, Carine J M Doggen

    BACKGROUND Telehealth interventions, that is, health care provided over a distance using information and communication technology, are suggested as a solution to rising health care costs by reducing hospital service use. However, the extent to which this is possible is unclear. OBJECTIVE The aim of this study is to evaluate the effect of telehealth on the use of hospital services, that is, (duration of) hospitalizations, and to compare the effects between telehealth types and health conditions. METHODS We searched PubMed, Scopus, and the Cochrane Library from inception until April 2019. Peer-reviewed randomized controlled trials (RCTs) reporting the effect of telehealth interventions on hospital service use compared with usual care were included. Risk of bias was assessed using the Cochrane Risk of Bias 2 tool and quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation guidelines. RESULTS We included 127 RCTs in the meta-analysis. Of these RCTs, 82.7% (105/127) had a low risk of bias or some concerns overall. High-quality evidence shows that telehealth reduces the risk of all-cause or condition-related hospitalization by 18 (95% CI 0-30) and 37 (95% CI 20-60) per 1000 patients, respectively. We found high-quality evidence that telehealth leads to reductions in the mean all-cause and condition-related hospitalizations, with 50 and 110 fewer hospitalizations per 1000 patients, respectively. Overall, the all-cause hospital days decreased by 1.07 (95% CI −1.76 to −0.39) days per patient. For hospitalized patients, the mean hospital stay for condition-related hospitalizations decreased by 0.89 (95% CI −1.42 to −0.36) days. The effects were similar between telehealth types and health conditions. A trend was observed for studies with longer follow-up periods yielding larger effects. CONCLUSIONS Small to moderate reductions in hospital service use can be achieved using telehealth. It should be noted that, despite the large number of included studies, uncertainties around the magnitude of effects remain, and not all effects are statistically significant.

  • Open Access

    Orthopaedic Consequences of Slipped Capital Femoral Epiphysis in Adults

    by D. Lazovic, G. Peters

    Slipping of the femoral head usually occurs at the beginning of puberty. With sexual hormone deficiency the growth plates remain open with the danger of a Slipped Capital Femoral Epiphysis (SCFE) beyond the normal age of growth. In several endocrine disorders such as hypothyroidism or growth hormone deficiency, and especially during supplemental therapy with hormones, SCFE can occur. SCFE can occur even if the hormonal replacement therapy has stopped. Since 1984 we have seen and treated 7 adult patients (6 male, 1 female) with SCFE. They were between 17 and 36 years old. Due to the lack of sexual hormones three patients had severe osteoporosis which caused difficulties in surgical treatment. From the orthopaedic point of view regular clinical and radiological check-ups are necessary in patients with open physes beyond the normal growth age - especially in patients with endocrine dysfunction and hormonal supplement therapy. These reviews have to be continued until the growth plates are closed be-cause SCFE occur even after hormonal replacement has been stopped for years. Prophylactic screwing of the opposite hip is also recommended in high risk patients.