Shunsuke Hayashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shunsuke Hayashi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Ken Hayashi
Hayashi Eye Hospital, Fukuoka, Japan
3 shared publications Motoaki Yoshida
Hayashi Eye Hospital (M.Y., K.H., K.N.), Fukuoka, Japan
2 shared publications- Motoaki Yoshida
Hayashi Eye Hospital, Fukuoka, Japan
2 shared publications Daiji Ikeda
Department of Chemistry and Biotechnology, Graduate School of Engineering, Tottori University
1 shared publicationGraham Palmer
Department of Biochemistry and Cell Biology, MS 140, Rice University, 6100 Main, Houston, TX 77005-1892, USA
1 shared publicationHideyuki Nobuto
Department of Chemistry and Biotechnology, Graduate School of Engineering, Tottori University
1 shared publication
Latest Publications
- 9 September 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Comparison of the functional defocus curve between eyes with diffractive multifocal intraocular lenses and age-stratified phakic eyes
Purpose: To compare the functional defocus curve between eyes with diffractive multifocal intraocular lenses (DMIOLs) and age-stratified phakic eyes with clear lenses. Setting: Hayashi Eye Hospital, Fukuoka, Japan. Design: Prospective comparative study. Methods: 85 eyes of 85 patients aged 60 years or older with DMIOLs (Alcon PanOptix, n = 40; Johnson & Johnson Odyssey, n = 45) and 380 phakic eyes of patients in their 30s, 40s, 50s, and 60s were enrolled. Corrected distance visual acuity (CDVA) at various simulated distances was measured at 3 months postoperatively using an all-distance vision tester and compared between groups. Results: Mean corrected distance VA at most distances was significantly worse in the DMIOL groups than in phakic patients in their 30s ( P ≤ .002). Compared with phakic patients in their 40s, the PanOptix group had significantly better corrected distance near VA (CDNVA) at 0.3 m and intermediate VA (CDIVA) at 0.5 m, but worse CDIVA at 1.0 m, whereas the Odyssey group had better CDNVA but worse CDIVA at 0.7 and 1.0 m ( P ≤ .002). Mean CDNVA and CDIVAs at 0.5 and 0.7 m were significantly better in the DMIOL groups than in phakic patients in their 50s and 60s ( P < .001), except for CDIVA at 0.7 m in patients in their 50s. Conclusions: The functional defocus curve in eyes with DMIOLs was comparable with that in phakic eyes of patients in their 40s and superior to that in phakic eyes of patients in their 50s and 60s, indicating that DMIOLs may restore the functional range of vision to that of phakic patients in their 40s.
- 9 September 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Comparison of the functional defocus curve between eyes with diffractive multifocal intraocular lenses and age-stratified phakic eyes
Purpose: To compare the functional defocus curve between eyes with diffractive multifocal intraocular lenses (DMIOLs) and age-stratified phakic eyes with clear lenses. Setting: Hayashi Eye Hospital, Fukuoka, Japan. Design: Prospective comparative study. Methods: 85 eyes of 85 patients aged 60 years or older with DMIOLs (Alcon PanOptix, n = 40; Johnson & Johnson Odyssey, n = 45) and 380 phakic eyes of patients in their 30s, 40s, 50s, and 60s were enrolled. Corrected distance visual acuity (CDVA) at various simulated distances was measured at 3 months postoperatively using an all-distance vision tester and compared between groups. Results: Mean corrected distance VA at most distances was significantly worse in the DMIOL groups than in phakic patients in their 30s ( P ≤ .002). Compared with phakic patients in their 40s, the PanOptix group had significantly better corrected distance near VA (CDNVA) at 0.3 m and intermediate VA (CDIVA) at 0.5 m, but worse CDIVA at 1.0 m, whereas the Odyssey group had better CDNVA but worse CDIVA at 0.7 and 1.0 m ( P ≤ .002). Mean CDNVA and CDIVAs at 0.5 and 0.7 m were significantly better in the DMIOL groups than in phakic patients in their 50s and 60s ( P < .001), except for CDIVA at 0.7 m in patients in their 50s. Conclusions: The functional defocus curve in eyes with DMIOLs was comparable with that in phakic eyes of patients in their 40s and superior to that in phakic eyes of patients in their 50s and 60s, indicating that DMIOLs may restore the functional range of vision to that of phakic patients in their 40s.
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 979-985
Comparison of visual performance among three higher-order aspheric enhanced monofocal intraocular lenses and a standard aspheric monofocal lens
Purpose: To compare visual performance among 3 types of higher-order aspheric enhanced monofocal intraocular lenses (IOLs) and a standard aspheric monofocal IOL. Setting: Hayashi Eye Hospital, Fukuoka, Japan. Design: Randomized comparative study. Methods: 344 eyes of 172 patients scheduled for phacoemulsification were randomly assigned to one of the 4 groups according to the IOL type: 3 types of enhanced monofocal IOL, (1) Eyhance, (2) Impress, and (3) NSP-3, and a standard monofocal IOL, (4) Tecnis monofocal. At 2 months postoperatively, monocular and binocular distance-corrected visual acuity (VA) from far to near simulated distances, photopic and mesopic contrast VA, and degree of halo and glare symptoms were measured and compared among groups. Results: Mean monocular and binocular distance-corrected intermediate VA at 0.5, 0.7, and 1.0 m was essentially better in the 3 enhanced monofocal IOL groups than in the standard monofocal IOL group ( P ≤ .04), whereas mean far and near distance-corrected VAs at 0.3, 2.0, 3.0, 5.0, and ∞ m did not differ significantly among the 4 groups. Mean photopic and mesopic contrast VA and the size and intensity of halo and glare symptoms did not differ significantly among groups. Conclusions: The 3 enhanced monofocal IOL types evaluated provided significantly better intermediate VA than a standard monofocal IOL with no significant deterioration in contrast sensitivity or photic symptoms. All visual performance test results examined were comparable among the 3 enhanced monofocal IOL types, suggesting that enhanced monofocal IOLs can serve as a replacement for standard monofocal IOLs.
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 979-985
Comparison of visual performance among three higher-order aspheric enhanced monofocal intraocular lenses and a standard aspheric monofocal lens
Purpose: To compare visual performance among 3 types of higher-order aspheric enhanced monofocal intraocular lenses (IOLs) and a standard aspheric monofocal IOL. Setting: Hayashi Eye Hospital, Fukuoka, Japan. Design: Randomized comparative study. Methods: 344 eyes of 172 patients scheduled for phacoemulsification were randomly assigned to one of the 4 groups according to the IOL type: 3 types of enhanced monofocal IOL, (1) Eyhance, (2) Impress, and (3) NSP-3, and a standard monofocal IOL, (4) Tecnis monofocal. At 2 months postoperatively, monocular and binocular distance-corrected visual acuity (VA) from far to near simulated distances, photopic and mesopic contrast VA, and degree of halo and glare symptoms were measured and compared among groups. Results: Mean monocular and binocular distance-corrected intermediate VA at 0.5, 0.7, and 1.0 m was essentially better in the 3 enhanced monofocal IOL groups than in the standard monofocal IOL group ( P ≤ .04), whereas mean far and near distance-corrected VAs at 0.3, 2.0, 3.0, 5.0, and ∞ m did not differ significantly among the 4 groups. Mean photopic and mesopic contrast VA and the size and intensity of halo and glare symptoms did not differ significantly among groups. Conclusions: The 3 enhanced monofocal IOL types evaluated provided significantly better intermediate VA than a standard monofocal IOL with no significant deterioration in contrast sensitivity or photic symptoms. All visual performance test results examined were comparable among the 3 enhanced monofocal IOL types, suggesting that enhanced monofocal IOLs can serve as a replacement for standard monofocal IOLs.
- 21 June 2022
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 242, 221-227
Comparison of Long-Term Corneal Astigmatic Changes After Cataract Surgery in Eyes With Superior or Horizontal Clear Corneal Incisions
- 21 June 2022
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 242, 221-227
Comparison of Long-Term Corneal Astigmatic Changes After Cataract Surgery in Eyes With Superior or Horizontal Clear Corneal Incisions
- 30 August 2021
- Published by Springer Nature in Eye
- Vol. 36 (10) , 1872-1877
Progression of posterior vitreous detachment after cataract surgery
Purpose To compare the progression of posterior vitreous detachment (PVD) between eyes that underwent cataract surgery and eyes that did not undergo surgery in non-highly myopic patients. Methods One-hundred twenty-five eyes of 125 patients scheduled for phacoemulsification and 125 eyes of 125 age-matched patients who did not undergo surgery were enrolled. PVD status was evaluated using swept-source optical coherence tomography at 2 days (baseline), and 1, 3, 6, and 12 months postoperatively, and classified into five stages: 0 (no), 1 (paramacular), 2 (perifoveal), 3 (peripapillary), and 4 (complete). The PVD stage and incidence of progression to complete PVD were compared between groups. Results The mean PVD stage significantly progressed over the 12 months in the surgery group (P = 0.0004), but did not change significantly in the non-surgery group. The PVD stage did not differ significantly between groups at 2 days, or 1, 3, and 6 months postoperatively, but was significantly more progressed in the surgery group than in the non-surgery group at 12 months (P = 0.0390). After adjusting for age, sex, axial length, and baseline PVD stage, the relative risk for progression to complete PVD was 7.1-fold higher in the surgery group than in the non-surgery group (P < 0.0001, 95% confidence interval 2.9–17.3). Conclusion PVD progressed significantly faster in eyes after cataract surgery compared with eyes that did not undergo surgery, and the relative risk of progression to complete PVD was approximately seven-fold higher within 1 year, indicating that the risk for PVD-related diseases is high after cataract surgery.
- 30 August 2021
- Published by Springer Nature in Eye
- Vol. 36 (10) , 1872-1877
Progression of posterior vitreous detachment after cataract surgery
Purpose To compare the progression of posterior vitreous detachment (PVD) between eyes that underwent cataract surgery and eyes that did not undergo surgery in non-highly myopic patients. Methods One-hundred twenty-five eyes of 125 patients scheduled for phacoemulsification and 125 eyes of 125 age-matched patients who did not undergo surgery were enrolled. PVD status was evaluated using swept-source optical coherence tomography at 2 days (baseline), and 1, 3, 6, and 12 months postoperatively, and classified into five stages: 0 (no), 1 (paramacular), 2 (perifoveal), 3 (peripapillary), and 4 (complete). The PVD stage and incidence of progression to complete PVD were compared between groups. Results The mean PVD stage significantly progressed over the 12 months in the surgery group (P = 0.0004), but did not change significantly in the non-surgery group. The PVD stage did not differ significantly between groups at 2 days, or 1, 3, and 6 months postoperatively, but was significantly more progressed in the surgery group than in the non-surgery group at 12 months (P = 0.0390). After adjusting for age, sex, axial length, and baseline PVD stage, the relative risk for progression to complete PVD was 7.1-fold higher in the surgery group than in the non-surgery group (P < 0.0001, 95% confidence interval 2.9–17.3). Conclusion PVD progressed significantly faster in eyes after cataract surgery compared with eyes that did not undergo surgery, and the relative risk of progression to complete PVD was approximately seven-fold higher within 1 year, indicating that the risk for PVD-related diseases is high after cataract surgery.
- 5 September 2011
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 40 (9) , 953-955
Palladium-catalyzed Regio- and Diastereoselective Allylic Alkylation in Ionic Liquids
Palladium-catalyzed regio- and diastereoselective allylic alkylations using ionic liquids (ILs) as a solvent were demonstrated. The reaction using diethyl(2-methoxyethyl)methylammonium bis(trifluoromethanesulfonyl)amide ([N221ME][NTf2]) or ethylhexyldimethylammonium bis(trifluoromethanesulfonyl)amide ([N6211][NTf2]) as solvent realized the recyclable use of the palladium catalyst while maintaining excellent regioselectivity and diastereoselectivity.
- 5 September 2011
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 40 (9) , 953-955
Palladium-catalyzed Regio- and Diastereoselective Allylic Alkylation in Ionic Liquids
Palladium-catalyzed regio- and diastereoselective allylic alkylations using ionic liquids (ILs) as a solvent were demonstrated. The reaction using diethyl(2-methoxyethyl)methylammonium bis(trifluoromethanesulfonyl)amide ([N221ME][NTf2]) or ethylhexyldimethylammonium bis(trifluoromethanesulfonyl)amide ([N6211][NTf2]) as solvent realized the recyclable use of the palladium catalyst while maintaining excellent regioselectivity and diastereoselectivity.
- 1 July 2004
- Published by Elsevier in Journal of Inorganic Biochemistry
- Vol. 98 (7) , 1223-1228
Hydroxylamine and hydrazine bind directly to the heme iron of the heme–heme oxygenase-1 complex
- 1 July 2004
- Published by Elsevier in Journal of Inorganic Biochemistry
- Vol. 98 (7) , 1223-1228
Hydroxylamine and hydrazine bind directly to the heme iron of the heme–heme oxygenase-1 complex