ACAlejandro Castilla

Alejandro Castilla

*This is an algorithmically generated author record based on publicly available information.

Alejandro Castilla has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Conceptual design of a high reactive-power ferroelectric fast reactive tuner

    by Ilan Ben-Zvi, Graeme Burt, Alejandro Castilla, Alick Macpherson, Nicholas Shipman

    We present a novel design of a ferroelectric fast reactive tuner (FE-FRT) capable of modulating mega-VAR reactive power on a submicrosecond timescale. The high reactive power capability of our design extends the range of applications of reactive tuners to numerous applications. We present a detailed analytical model of the performance of a megawatt-class reactive power device and benchmark it against finite-element method eigenmode and frequency domain electromagnetic simulations. We introduce new features, including an annulus design for the ferroelectric capacitors and capacitive window coupling to the cavity. We consider thermal design issues and nonlinear effects in the ferroelectric. The model covers several configurations, allowing control of the frequency of superconducting and normal-conducting cavities in a variety of applications and frequencies. We calculate that the FE-FRT designed should be capable of handling around 0.45 MVAR of reactive power with around 3 kW of resistive losses, providing a frequency tuning range of 8 kHz in an example of 400 MHz cavity geometry. Published by the American Physical Society 2024


  • Open Access

    Ka-band linearizer structure studies for a compact light source

    by A. Castilla, R. Apsimon, G. Burt, X. Wu, A. Latina, X. Liu, I. Syratchev, W. Wuensch, B. Spataro, A. W. Cross

    The CompactLight design for a next-generation x-ray free-electron laser utilizes a C-band injector. This requires that the harmonic system used to linearize the beam’s phase space must operate at X-band rf or higher. We investigate the optimum frequency for the harmonic system in the range of frequencies from 12 to 48 GHz. We describe the reasoning behind selecting 36 GHz (Ka-band) as our working harmonic frequency. The full linearizer system design including the power source, pulse compressor, and linearizing structure, along with options, is considered and presented. These designs are compared in terms of rf and beam dynamics performance. Two potential MW-level rf sources are discussed; a multibeam klystron and a gyro-klystron, while a klystron-based upconverter with an X-band driver is briefly discussed as an alternative path if even higher peak powers are needed. To further increase peak power, novel options for pulse compressors at Ka-band are discussed. Traveling and standing wave solutions for the structure are presented.


  • Open Access

    High-power ferro-electric fast reactive tuner

    by Ilan Ban-Zvi, A. Castilla, A. Macpherson, N. Shipman

    The U.S. Department of Energy's Office of Scientific and Technical Information


  • Open Access

    Pushing the Capture Limit of Thermionic Gun Linacs

    by Sadiq Setiniyaz, Alejandro Castilla, Julian McKenzie, Robert Apsimon, Boris Militsyn, Deepa Angal-Kalinin, Graeme Burt

    Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving uncaptured electrons to cause problems due to back bombardment, shortening of cathode life, etc. Any solution to increase capture should be effective, simple, reliable, compact, and low cost in order to be adopted by industry. To address this, we present the design of a 6 MeV high capture efficiency S-band electron linac that captures 90% of the initial DC beam. This linac does not require any extra parts that would increase the cost as the high efficiency is achieved via a low-field-amplitude in the first bunching cell to decrease the number of backstreaming electrons, to velocity bunch the electron beam, and recapture backstreaming electrons. Under the low field amplitude, any electrons launched at decelerating phases travel backward with low speeds, thus most of them can catch the next RF cycle, and get re-accelerated/recaptured. As the electron speed is low, the cell length is also shorter than existing linacs. Such a short field is achieved by the use of asymmetric cells with differential coupling to the side-coupled cells. Our novel design has implications for all commercial high current thermionic gun linacs for increasing beam current and increasing cathode lifetime.

  • Open Access

    Pushing the capture limit of thermionic gun linacs

    by Sadiq Setiniyaz, Alejandro Castilla, Julian McKenzie, Robert Apsimon, Boris Militsyn, Deepa Angal-Kalinin, Graeme Burt

    Although accelerator technology has matured sufficiently, state-of-the-art x-ray linacs for radiotherapy and cargo-scanning capture merely 30%–50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving uncaptured electrons to cause problems such as back bombardment on the cathode leading to a shortening of cathode life. Any solution to increase capture should be effective, simple, reliable, compact, and low cost in order to be adopted by the industry. To address this, we present the design of a 6 MeV high capture efficiency S-band electron linac that captures 90% of the initial dc beam. This linac does not require any extra parts that would increase the cost as the high efficiency is achieved via a low-field amplitude in the first bunching cell to decrease the number of back-streaming electrons, to velocity bunch the electron beam, and recapture back-streaming electrons. Under the low field amplitude, any electrons launched at decelerating phases travel backward with low speeds, thus most of them can catch the next rf cycle, and get reaccelerated/recaptured. As the electron speed is low, the cell length is also shorter than existing linacs. Such a short field is achieved by the use of asymmetric cells with differential coupling to the side-coupled cells. Our novel design has implications for all commercial high current thermionic gun linacs for increasing beam current and increasing cathode lifetime.