Linglin Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Linglin Jiang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Jun Yan
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang, China
2 shared publicationsMarko Hočevar
Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana, Slovenia
2 shared publicationsYong Wang
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang, China
2 shared publicationsHoulin Liu
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang, China
1 shared publication- Houlin Liu
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
1 shared publication Jie Chen
School of Mechanical Engineering, Beijing Institute of Technology, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 17 February 2022
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 14 (2)
Optimization and CFD performance analysis of an automotive coolant pump
The blade outlet angle, wrap angle, and number of blades of the impeller are optimized to increase the pumping efficiency of the automotive coolant pump while keeping the size constant. Three new variants were designed and the optimal one was selected for the comparison with the original scheme. The experiment was conducted to test the hydraulic performance of the optimized impeller. The results show that the energy characteristics of the optimized impeller are in reasonable agreement with the experimental data. The energy characteristics and internal flow details of original scheme and optimized scheme are analyzed and compared. It was found that increasing the wrap angle while decreasing blade outlet angle appropriately can improve the flow conditions and the pressure distribution in the impeller and the volute, especially at low flow rates. At the designed flow rate, increasing the wrap angle while decreasing the number of blades and blade outlet angle can significantly increase the efficiency of the pump. And the maximum efficiency of the optimized impeller is 4.8% higher than the efficiency of the original impeller. The results of the study can guide designers in optimizing an automotive centrifugal coolant pump and reduce energy consumption of the automotive cooling system.
- 17 February 2022
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 14 (2)
Open AccessOptimization and CFD performance analysis of an automotive coolant pump
The blade outlet angle, wrap angle, and number of blades of the impeller are optimized to increase the pumping efficiency of the automotive coolant pump while keeping the size constant. Three new variants were designed and the optimal one was selected for the comparison with the original scheme. The experiment was conducted to test the hydraulic performance of the optimized impeller. The results show that the energy characteristics of the optimized impeller are in reasonable agreement with the experimental data. The energy characteristics and internal flow details of original scheme and optimized scheme are analyzed and compared. It was found that increasing the wrap angle while decreasing blade outlet angle appropriately can improve the flow conditions and the pressure distribution in the impeller and the volute, especially at low flow rates. At the designed flow rate, increasing the wrap angle while decreasing the number of blades and blade outlet angle can significantly increase the efficiency of the pump. And the maximum efficiency of the optimized impeller is 4.8% higher than the efficiency of the original impeller. The results of the study can guide designers in optimizing an automotive centrifugal coolant pump and reduce energy consumption of the automotive cooling system.
- 2 August 2021
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 9641-9657
Cooling performance and power consumption analysis of automobile engine cooling system
In order to study the cooling performance of the engine cooling system, as well as investigating the power consumption of the conventional electronic control cooling system with the electronic control cooling system with fuzzy controller, the fuzzy controller was designed and corresponding system models were established by using one-dimensional fluid system simulation software Flowmaster and Math software Matlab/Simulink. The analysis of the cooling performance of the engine cooling system was completed to compare the simulation results of two models. The results show that simulation values are close to the experiment values and temperature deviation of the coolant at outlet is less than 1% and the simulation method can be relied on. Heat dissipation rate and pump rotational speed have great influence on the temperature change of the engine coolant. The temperature difference increases from 0°C to 15°C with the heat dissipation rate increases from 5 kW to 45 kW when the rotational speed of the pump and the fan are 2300 r/min and 400 r/min, respectively, and the temperature difference decreases from 15°C to 5°C with the rotational speed of the pump increases from 1400 r/min to 5000 r/min when the rotational speed of the fan and the heat dissipation rate are 700 r/min and 25 kW, respectively. While fan rotational speed hardly affects the temperature change when rotational speed is above 700 r/min. Under NEDC (New European Driving Cycle) condition, compared with the conventional cooling system, the effect of reducing energy consumption by using the cooling system with fuzzy controller is obvious, the energy consumption of the electronic fan and the electronic pump decreases from 227 kJ in conventional electronic control cooling system to 134.8 kJ in electronic control cooling system with fuzzy controller and the energy consumption of the system reduces by 40.6%.
- 2 August 2021
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (1) , 9641-9657
Cooling performance and power consumption analysis of automobile engine cooling system
In order to study the cooling performance of the engine cooling system, as well as investigating the power consumption of the conventional electronic control cooling system with the electronic control cooling system with fuzzy controller, the fuzzy controller was designed and corresponding system models were established by using one-dimensional fluid system simulation software Flowmaster and Math software Matlab/Simulink. The analysis of the cooling performance of the engine cooling system was completed to compare the simulation results of two models. The results show that simulation values are close to the experiment values and temperature deviation of the coolant at outlet is less than 1% and the simulation method can be relied on. Heat dissipation rate and pump rotational speed have great influence on the temperature change of the engine coolant. The temperature difference increases from 0°C to 15°C with the heat dissipation rate increases from 5 kW to 45 kW when the rotational speed of the pump and the fan are 2300 r/min and 400 r/min, respectively, and the temperature difference decreases from 15°C to 5°C with the rotational speed of the pump increases from 1400 r/min to 5000 r/min when the rotational speed of the fan and the heat dissipation rate are 700 r/min and 25 kW, respectively. While fan rotational speed hardly affects the temperature change when rotational speed is above 700 r/min. Under NEDC (New European Driving Cycle) condition, compared with the conventional cooling system, the effect of reducing energy consumption by using the cooling system with fuzzy controller is obvious, the energy consumption of the electronic fan and the electronic pump decreases from 227 kJ in conventional electronic control cooling system to 134.8 kJ in electronic control cooling system with fuzzy controller and the energy consumption of the system reduces by 40.6%.