Gökçe Gültekin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gökçe Gültekin has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Busemnaz Avşar Aksu
Department of Audiology, Faculty of Health Sciences, Üsküdar University, Istanbul, Türkiye
7 shared publications - Didem Şahin Ceylan
Department of Audiology, Faculty of Health Sciences, Üsküdar University, Istanbul, Türkiye
7 shared publications - Yeter Saçlı
Department of Audiology, Faculty of Health Sciences, Üsküdar University, Istanbul, Türkiye
6 shared publications - Büşra Aksu
Department of Audiology, Faculty of Health Sciences, Üsküdar University, Istanbul, Turkey
2 shared publications Ahmet Atas
Department of Otorhinolaryngology, Istanbul University-Cerrahpasa, Cerrahpasa Medical Faculty, Istanbul, Turkey
1 shared publication- Berna Aldemir
Department of Audiology, Faculty of Health Sciences, Uskudar University , Istanbul 34662
1 shared publication
Latest Publications
- 19 July 2026
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (10) , 6283-6295
Temporal and speech outcomes in bimodal cochlear implant users: The effect of device delay mismatch
Purpose The aim of this study is to characterize and compare the spectral-temporal features of speech, processing performance, and speech perception in noisy environments among bimodal cochlear implant (CI) users. Additionally, the study aims to examine intra-individual differences in synchronous and asynchronous use among individuals in whom the delay mismatch between the hearing aid (HA) and the CI has been reduced. Methods Forty-one bimodal cochlear implant users aged between 15 and 45 years participated in the study. Participants were divided into two groups based on the presence of the temporal synchronization (20 Cochlear, 21 MED-EL). In the first session, asynchronous data were collected using the Modulation Detection Threshold Test (easyMDT), Random Gap Detection Test (RGDT), Spectral-temporally Modulated Ripple Test (SMRT), and Turkish Matrix Test (TMT). For MED-EL users, the CI and HA were made temporally synchronized using a bimodal synchronization setting. In the second session, two CI programs were created, and all tests were repeated for synchronized fitting. In the programs, only the CI’s speech processing strategies were used differently (HDCIS only and a combination of FSP and HDCIS). Results Within the MED-EL users, synchronous mode comparisons demonstrated that the program using both strategies yielded improvements: a 2.3 ms reduction in RGDT composite score, a 1.31 dB decrease in easyMDT modulation detection threshold, a 5.56 dB SNR improvement in the Adaptive procedure of TMT, and a 6% increase in the Non-Adaptive procedure of TMT (p < 0.05). Conclusions In conclusion, the exploratory analysis suggests a possible relationship between temporal synchronization in bimodal CI use and outcomes related to temporal processing and speech perception in noise. Given the variability in inter-individual parameters, these findings should be considered preliminary and interpreted cautiously until confirmed by future controlled or longitudinal studies.
- 19 July 2026
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (10) , 6283-6295
Temporal and speech outcomes in bimodal cochlear implant users: The effect of device delay mismatch
Purpose The aim of this study is to characterize and compare the spectral-temporal features of speech, processing performance, and speech perception in noisy environments among bimodal cochlear implant (CI) users. Additionally, the study aims to examine intra-individual differences in synchronous and asynchronous use among individuals in whom the delay mismatch between the hearing aid (HA) and the CI has been reduced. Methods Forty-one bimodal cochlear implant users aged between 15 and 45 years participated in the study. Participants were divided into two groups based on the presence of the temporal synchronization (20 Cochlear, 21 MED-EL). In the first session, asynchronous data were collected using the Modulation Detection Threshold Test (easyMDT), Random Gap Detection Test (RGDT), Spectral-temporally Modulated Ripple Test (SMRT), and Turkish Matrix Test (TMT). For MED-EL users, the CI and HA were made temporally synchronized using a bimodal synchronization setting. In the second session, two CI programs were created, and all tests were repeated for synchronized fitting. In the programs, only the CI’s speech processing strategies were used differently (HDCIS only and a combination of FSP and HDCIS). Results Within the MED-EL users, synchronous mode comparisons demonstrated that the program using both strategies yielded improvements: a 2.3 ms reduction in RGDT composite score, a 1.31 dB decrease in easyMDT modulation detection threshold, a 5.56 dB SNR improvement in the Adaptive procedure of TMT, and a 6% increase in the Non-Adaptive procedure of TMT (p < 0.05). Conclusions In conclusion, the exploratory analysis suggests a possible relationship between temporal synchronization in bimodal CI use and outcomes related to temporal processing and speech perception in noise. Given the variability in inter-individual parameters, these findings should be considered preliminary and interpreted cautiously until confirmed by future controlled or longitudinal studies.
- 23 April 2026
- Published by Springer Nature in Attention, Perception, & Psychophysics
- Vol. 88 (5)
Hot–cold water sound perception and auditory-thermal discrimination
This study aimed to determine whether individuals can discriminate the temperature state of water using auditory cues alone and to identify the acoustic, perceptual, and neurocognitive factors associated with this ability. Sixty-three volunteers aged 18-25 years with normal hearing participated. Participants were presented with prerecorded sounds of hot and cold water being poured into four types of cups (glass, plastic, paper, porcelain) and completed discrimination and matching tasks while auditory processing and event-related potential measures were obtained. Results from Spectral-Temporally Modulated Ripple Test (SMRT), Frequency Pattern Test (FPT), and P300 recordings were collected. Significant SMRT differences (p < 0.05) were observed among participants who correctly identified temperature differences in porcelain cup stimuli. For paper cup stimuli, P300 amplitudes (p < 0.05) and FPT scores (p < 0.05) differed significantly between correct and incorrect responders. Gender significantly influenced performance with glass cup stimuli and in participants who described acoustic features (frequency, intensity, duration) for porcelain stimuli (p < 0.05). Despite normal audiological findings, individuals exhibited notable variability in perceiving the same acoustic stimuli. Auditory-thermal discrimination appears to rely on higher-order auditory processing and neurocognitive mechanisms rather than basic auditory sensitivity. This is the first study to link auditory‑thermal discrimination with SMRT/FPT and P300 measures in normal‑hearing young adults.
- 23 April 2026
- Published by Springer Nature in Attention, Perception, & Psychophysics
- Vol. 88 (5)
Hot–cold water sound perception and auditory-thermal discrimination
This study aimed to determine whether individuals can discriminate the temperature state of water using auditory cues alone and to identify the acoustic, perceptual, and neurocognitive factors associated with this ability. Sixty-three volunteers aged 18-25 years with normal hearing participated. Participants were presented with prerecorded sounds of hot and cold water being poured into four types of cups (glass, plastic, paper, porcelain) and completed discrimination and matching tasks while auditory processing and event-related potential measures were obtained. Results from Spectral-Temporally Modulated Ripple Test (SMRT), Frequency Pattern Test (FPT), and P300 recordings were collected. Significant SMRT differences (p < 0.05) were observed among participants who correctly identified temperature differences in porcelain cup stimuli. For paper cup stimuli, P300 amplitudes (p < 0.05) and FPT scores (p < 0.05) differed significantly between correct and incorrect responders. Gender significantly influenced performance with glass cup stimuli and in participants who described acoustic features (frequency, intensity, duration) for porcelain stimuli (p < 0.05). Despite normal audiological findings, individuals exhibited notable variability in perceiving the same acoustic stimuli. Auditory-thermal discrimination appears to rely on higher-order auditory processing and neurocognitive mechanisms rather than basic auditory sensitivity. This is the first study to link auditory‑thermal discrimination with SMRT/FPT and P300 measures in normal‑hearing young adults.
- 29 October 2025
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 184 (11) , 1-8
School-age hearing screening outcomes: analysis of 24,258 students
This study aimed to characterize the audiological profiles of first-grade primary school students in the Üsküdar district and to determine the prevalence of hearing impairments within this population. Additionally, the study sought to highlight the benefits of implementing a school-age hearing screening protocol. Between November 2023 and June 2025, a total of 24,258 first-grade students enrolled in 107 primary schools located in the Üsküdar district were reached, along with their families; however, the study proceeded with 15,073 students whose parents provided consent for hearing screening. Initial hearing screenings using audiometry were conducted within the schools. Children who failed the screening were referred for further evaluation, including pure-tone audiometry testing. Of the 15,073 students, 14,279 (94.7%) passed the screening, while 794 (5.3%) failed and were referred for advanced diagnostic evaluation. Of the referred students, only 358 (45.1%) completed the advanced diagnostic assessment. Among these evaluated children, hearing loss was confirmed in 156 students (43.6% of those assessed): 128 with bilateral hearing loss and 28 with unilateral hearing loss. Sensorineural hearing loss was detected in 9 children (5.8% of those with confirmed hearing loss), while conductive hearing loss was identified in 147 children (94.2%). Conclusion: In school-age hearing screenings, approximately 3 out of every 100 children fail the screening test, and 1 out of every 5 children who fail the test is ultimately diagnosed with hearing loss. Increasing awareness, promoting related research, and educating families are essential for the early detection and treatment of hearing loss. What Is Known: • In many countries, hearing screenings for school-aged children are routinely conducted in accordance with established protocols. • The prevalence of hearing loss identified through school-age hearing screening is higher than the rate determined through newborn hearing screening. What Is New: • The large difference between the number of children reached and the number of children screened has been associated with the low level of public awareness regarding hearing loss and its effects. • The need to include preschool screening programs in hearing screening protocols nationwide in Turkiye has become evident.
- 29 October 2025
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 184 (11) , 1-8
School-age hearing screening outcomes: analysis of 24,258 students
This study aimed to characterize the audiological profiles of first-grade primary school students in the Üsküdar district and to determine the prevalence of hearing impairments within this population. Additionally, the study sought to highlight the benefits of implementing a school-age hearing screening protocol. Between November 2023 and June 2025, a total of 24,258 first-grade students enrolled in 107 primary schools located in the Üsküdar district were reached, along with their families; however, the study proceeded with 15,073 students whose parents provided consent for hearing screening. Initial hearing screenings using audiometry were conducted within the schools. Children who failed the screening were referred for further evaluation, including pure-tone audiometry testing. Of the 15,073 students, 14,279 (94.7%) passed the screening, while 794 (5.3%) failed and were referred for advanced diagnostic evaluation. Of the referred students, only 358 (45.1%) completed the advanced diagnostic assessment. Among these evaluated children, hearing loss was confirmed in 156 students (43.6% of those assessed): 128 with bilateral hearing loss and 28 with unilateral hearing loss. Sensorineural hearing loss was detected in 9 children (5.8% of those with confirmed hearing loss), while conductive hearing loss was identified in 147 children (94.2%). Conclusion: In school-age hearing screenings, approximately 3 out of every 100 children fail the screening test, and 1 out of every 5 children who fail the test is ultimately diagnosed with hearing loss. Increasing awareness, promoting related research, and educating families are essential for the early detection and treatment of hearing loss. What Is Known: • In many countries, hearing screenings for school-aged children are routinely conducted in accordance with established protocols. • The prevalence of hearing loss identified through school-age hearing screening is higher than the rate determined through newborn hearing screening. What Is New: • The large difference between the number of children reached and the number of children screened has been associated with the low level of public awareness regarding hearing loss and its effects. • The need to include preschool screening programs in hearing screening protocols nationwide in Turkiye has become evident.
- 15 October 2025
- Published by Taylor & Francis in Archives of Environmental & Occupational Health
- Vol. 80 (10) , 265-273
Examination of audiologic findings and noise sensitivity in motorcycle couriers
This study evaluated peripheral hearing and noise sensitivity among motorcycle couriers in Istanbul. Participants comprised 31 couriers (29 males, 2 females; age: 28.51 ± 6.23) and 30 controls (27 males, 3 females; age: 27.03 ± 4.20). Assessment included Weinstein's Noise Sensitivity Scale, tympanometry, pure tone audiometry, and otoacoustic emissions. Couriers demonstrated significantly elevated hearing thresholds in the right ear at 500 Hz (p = 0.017), 1,000 Hz (p < 0.001), 2,000 Hz (p = 0.004), 4,000 Hz (p = 0.001), 6,000 Hz (p = 0.002), and 8,000 Hz (p < 0.001), and in the left ear at 4,000 Hz (p = 0.010) and 8,000 Hz (p = 0.039). Noise sensitivity scores were significantly higher (p = 0.031). Motorcycle couriers represent an occupational group vulnerable to hearing loss and heightened noise sensitivity. Protective measures should encompass environmental noise mitigation, speed limit regulation, and helmet redesign incorporating ear protection to promote hearing conservation and improve overall well-being.
- 15 October 2025
- Published by Taylor & Francis in Archives of Environmental & Occupational Health
- Vol. 80 (10) , 265-273
Examination of audiologic findings and noise sensitivity in motorcycle couriers
This study evaluated peripheral hearing and noise sensitivity among motorcycle couriers in Istanbul. Participants comprised 31 couriers (29 males, 2 females; age: 28.51 ± 6.23) and 30 controls (27 males, 3 females; age: 27.03 ± 4.20). Assessment included Weinstein's Noise Sensitivity Scale, tympanometry, pure tone audiometry, and otoacoustic emissions. Couriers demonstrated significantly elevated hearing thresholds in the right ear at 500 Hz (p = 0.017), 1,000 Hz (p < 0.001), 2,000 Hz (p = 0.004), 4,000 Hz (p = 0.001), 6,000 Hz (p = 0.002), and 8,000 Hz (p < 0.001), and in the left ear at 4,000 Hz (p = 0.010) and 8,000 Hz (p = 0.039). Noise sensitivity scores were significantly higher (p = 0.031). Motorcycle couriers represent an occupational group vulnerable to hearing loss and heightened noise sensitivity. Protective measures should encompass environmental noise mitigation, speed limit regulation, and helmet redesign incorporating ear protection to promote hearing conservation and improve overall well-being.
- 1 October 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (4) , 3359-3364
Sound, brain, and bias: Dissecting the Laurel–Yanny illusion with auditory and cognitive markers
This study aims to explore the acoustic, perceptual, and cognitive mechanisms underlying the Laurel–Yanny auditory illusion. A total of 60 volunteers aged between 18 and 28 years (M = 22.36 ± 2.17), all with normal hearing and a Montreal Cognitive Assessment score of ≥21, participated in the study. Participants' perceptions of the Laurel–Yanny auditory illusion were evaluated, and they were administered the Frequency Pattern Test, the Spectral-Temporally Modulated Ripple Test (SMRT), and the P300 test. A statistically significant difference was found in SMRT results between participants who perceived “Laurel” and those who perceived “Yanny,” with the “Yanny” group having a better SMRT performance (p = 0.026). No significant differences were observed between the groups in the results of the other assessments (p > 0.05). Among participants who perceived “Laurel,” a moderate negative correlation was found between SMRT results and P300 latency (r = −0.525, p < 0.01). These findings suggest that the differences in responses to the Laurel–Yanny auditory illusion may not solely be attributed to cognitive or attentional processes but may also involve differences in lower-level auditory processing mechanisms. The results indicate a potential interaction between auditory frequency resolution, spectral discrimination, and cognitive processing time.
- 1 October 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (4) , 3359-3364
Sound, brain, and bias: Dissecting the Laurel–Yanny illusion with auditory and cognitive markers
This study aims to explore the acoustic, perceptual, and cognitive mechanisms underlying the Laurel–Yanny auditory illusion. A total of 60 volunteers aged between 18 and 28 years (M = 22.36 ± 2.17), all with normal hearing and a Montreal Cognitive Assessment score of ≥21, participated in the study. Participants' perceptions of the Laurel–Yanny auditory illusion were evaluated, and they were administered the Frequency Pattern Test, the Spectral-Temporally Modulated Ripple Test (SMRT), and the P300 test. A statistically significant difference was found in SMRT results between participants who perceived “Laurel” and those who perceived “Yanny,” with the “Yanny” group having a better SMRT performance (p = 0.026). No significant differences were observed between the groups in the results of the other assessments (p > 0.05). Among participants who perceived “Laurel,” a moderate negative correlation was found between SMRT results and P300 latency (r = −0.525, p < 0.01). These findings suggest that the differences in responses to the Laurel–Yanny auditory illusion may not solely be attributed to cognitive or attentional processes but may also involve differences in lower-level auditory processing mechanisms. The results indicate a potential interaction between auditory frequency resolution, spectral discrimination, and cognitive processing time.
- 5 June 2025
- Published by Springer Nature in Indian Journal of Otolaryngology and Head & Neck Surgery
- Vol. 77 (8) , 2834-2841
An Occupational Disease in Car Wash and Auto Detailing Workers: Hearing Loss
The main aim of this study is to evaluate the hearing health of car wash and auto detailing workers. Audiologic findings of car cash and auto detailing workers in indoor and outdoor environments will be compared with normal hearing individuals. The study included 26 car wash and auto detailing workers working indoors (I-CD), 25 car wash and auto detailing workers working outdoors (O-CD) and a control group of 29 participants. All participants performed a hearing evaluation including Tympanometry, Pure Tone Audiometry (PTA), Transient Evoked Otoacoustic Emission (TEOAE) tests. Tympanometry results, a significant difference was obtained between the groups for left ear canal volume (p<0.05). Significant differences were obtained between the groups for PTA at 250 Hz, 500 Hz and 1000 Hz in the right and 500 Hz in the left ear; for TEOAE at 1000 Hz and 1500 Hz in the right and 1000 Hz in the left ear (p<0.05). Positive significant correlations were obtained between the duration of experience of I-CD workers and PTA at 500 Hz, 1000 Hz and 6000 Hz in the right and 125 Hz in the left ear; and between the duration of experience of O-CD workers and PTA at 2000 Hz in the right, 2000 Hz and 6000 Hz in the left ear (p<0.05).The synergistic effect of noise, chemical components and vibration threatens the hearing health of car wash and auto detailing workers.
- 5 June 2025
- Published by Springer Nature in Indian Journal of Otolaryngology and Head & Neck Surgery
- Vol. 77 (8) , 2834-2841
An Occupational Disease in Car Wash and Auto Detailing Workers: Hearing Loss
The main aim of this study is to evaluate the hearing health of car wash and auto detailing workers. Audiologic findings of car cash and auto detailing workers in indoor and outdoor environments will be compared with normal hearing individuals. The study included 26 car wash and auto detailing workers working indoors (I-CD), 25 car wash and auto detailing workers working outdoors (O-CD) and a control group of 29 participants. All participants performed a hearing evaluation including Tympanometry, Pure Tone Audiometry (PTA), Transient Evoked Otoacoustic Emission (TEOAE) tests. Tympanometry results, a significant difference was obtained between the groups for left ear canal volume (p<0.05). Significant differences were obtained between the groups for PTA at 250 Hz, 500 Hz and 1000 Hz in the right and 500 Hz in the left ear; for TEOAE at 1000 Hz and 1500 Hz in the right and 1000 Hz in the left ear (p<0.05). Positive significant correlations were obtained between the duration of experience of I-CD workers and PTA at 500 Hz, 1000 Hz and 6000 Hz in the right and 125 Hz in the left ear; and between the duration of experience of O-CD workers and PTA at 2000 Hz in the right, 2000 Hz and 6000 Hz in the left ear (p<0.05).The synergistic effect of noise, chemical components and vibration threatens the hearing health of car wash and auto detailing workers.
- 1 July 2024
- Published by Uskudar University in Journal of Health Sciences and Technologies
- Vol. 1 (2) , 1-8
Study of multiple intelligence types among undergraduate students: The case of the Faculty of Health Sciences Audiology Department and the Faculty of Communication
The theory of multiple intelligences suggests that people have different learning abilities. According to this theory, individuals should be evaluated in a total of 8 intelligence areas: verbal-linguistic, logical-mathematical, visual-spatial, musical-rhythmic, bodily-kinesthetic, interpersonal-social, personal-intrapersonal, naturalist-existentialist. The aim of our study is to determine and compare the dominant intelligence types of students in the Faculty of Health Sciences and the Faculty of Communication. The study included 100 students aged 22-27 who were admitted to the university with a numerical score type and who were 4th year students in the Audiology Department of the Faculty of Health Sciences, and 100 students aged 23-27 who were admitted to the university with a verbal score type and who were 4th year students in the Faculty of Communication. The logical-mathematical intelligence scores of the students in Audiology of the Faculty of Health Sciences were higher than those of the students of the Faculty of Communication (p<0,01). When evaluating each faculty within each faculty, the interpersonal intelligence of the students of the Faculty of Health Sciences is better than the verbal-linguistic intelligence, the logical-mathematical intelligence, the visual-spatial intelligence and the musical-rhythmical intelligence (p<0,05). Communication students' logical-mathematical intelligence was worse than all other types of intelligence (p<0,05). Their interpersonal intelligence was better than their visual-spatial, musical-rhythmic and bodily-kinesthetic intelligences (p<0,05). In this study, the Faculty of Communication was found to be the faculty with the least similarity to the Faculty of Audiology in terms of course content, according to the University's exemption standards, and the intelligence potential of the students was examined and the types of intelligence were compared. The significant results obtained in the comparisons suggest that these differences may be due to the theoretical and practical training given over 4 years and the emphasis placed on field placements in the final year.
- 1 July 2024
- Published by Uskudar University in Journal of Health Sciences and Technologies
- Vol. 1 (2) , 1-8
Study of multiple intelligence types among undergraduate students: The case of the Faculty of Health Sciences Audiology Department and the Faculty of Communication
The theory of multiple intelligences suggests that people have different learning abilities. According to this theory, individuals should be evaluated in a total of 8 intelligence areas: verbal-linguistic, logical-mathematical, visual-spatial, musical-rhythmic, bodily-kinesthetic, interpersonal-social, personal-intrapersonal, naturalist-existentialist. The aim of our study is to determine and compare the dominant intelligence types of students in the Faculty of Health Sciences and the Faculty of Communication. The study included 100 students aged 22-27 who were admitted to the university with a numerical score type and who were 4th year students in the Audiology Department of the Faculty of Health Sciences, and 100 students aged 23-27 who were admitted to the university with a verbal score type and who were 4th year students in the Faculty of Communication. The logical-mathematical intelligence scores of the students in Audiology of the Faculty of Health Sciences were higher than those of the students of the Faculty of Communication (p<0,01). When evaluating each faculty within each faculty, the interpersonal intelligence of the students of the Faculty of Health Sciences is better than the verbal-linguistic intelligence, the logical-mathematical intelligence, the visual-spatial intelligence and the musical-rhythmical intelligence (p<0,05). Communication students' logical-mathematical intelligence was worse than all other types of intelligence (p<0,05). Their interpersonal intelligence was better than their visual-spatial, musical-rhythmic and bodily-kinesthetic intelligences (p<0,05). In this study, the Faculty of Communication was found to be the faculty with the least similarity to the Faculty of Audiology in terms of course content, according to the University's exemption standards, and the intelligence potential of the students was examined and the types of intelligence were compared. The significant results obtained in the comparisons suggest that these differences may be due to the theoretical and practical training given over 4 years and the emphasis placed on field placements in the final year.
- 5 December 2023
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- p. 483
Mismatch Negativity as a Tool to Detect the Intensity Just Noticeable Difference
Mismatch negativity (MMN) essentially reflects auditory change detection. Although auditory change detection can potentially be assessed through behavioral auditory testing methods, the increased reliability of objective methods, such as MMN, makes them more valuable. The aim of this study was to detect and compare the intensity just noticeable difference using the MMN and a behavioral method. The level at which the intensity difference between the frequent stimulus and the infrequent stimulus was the lowest and the MMN wave elicited was accepted as the MMN threshold. A total of 60 subjects, 30 females (mean age 21.70, SD = 1.91 years) and 30 males (mean age 22.77, SD = 3.01), aged 20–30 years, were included in the study. In the whole sample, a significant difference was found between MMN thresholds obtained from the right ear side and MMN thresholds obtained from the left ear side, regardless of sex (p < 0:05). In the comparison of the values obtained using the behavioral method and MMN, no significant difference was found for either the right or the left side in both sexes (p > 0:05). The results showed that the values determined by the behavioral method and MMN on both the right and left ear sides were similar in both sexes.
- 5 December 2023
- Published by Polish Academy of Sciences Chancellery in Archives of Acoustics
- p. 483
Mismatch Negativity as a Tool to Detect the Intensity Just Noticeable Difference
Mismatch negativity (MMN) essentially reflects auditory change detection. Although auditory change detection can potentially be assessed through behavioral auditory testing methods, the increased reliability of objective methods, such as MMN, makes them more valuable. The aim of this study was to detect and compare the intensity just noticeable difference using the MMN and a behavioral method. The level at which the intensity difference between the frequent stimulus and the infrequent stimulus was the lowest and the MMN wave elicited was accepted as the MMN threshold. A total of 60 subjects, 30 females (mean age 21.70, SD = 1.91 years) and 30 males (mean age 22.77, SD = 3.01), aged 20–30 years, were included in the study. In the whole sample, a significant difference was found between MMN thresholds obtained from the right ear side and MMN thresholds obtained from the left ear side, regardless of sex (p < 0:05). In the comparison of the values obtained using the behavioral method and MMN, no significant difference was found for either the right or the left side in both sexes (p > 0:05). The results showed that the values determined by the behavioral method and MMN on both the right and left ear sides were similar in both sexes.
- 11 August 2021
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 27 (2) , 133-138
Facial and Auditory Recognition Abilities of Implanted Primary Schoolers
Objective: Emotions are often conveyed via visual and together with the auditory mode in social interaction. We aimed to investigate the ability to recognize facial and/or auditory emotions in school-aged children with cochlear implantation and healthy controls. Methods: All participants were asked to respond to facial emotions of Ekman and Friesen’s pictures, then auditory emotions, and last, they were asked to respond to video-based dynamic synchronous facial and auditory emotions. Results: The mean accuracy rates in recognizing anger (p = 0.025), surprise (p = 0.029), and neutral (p = 0.029) faces were significantly worse in children with cochlear implants (CIs) than in healthy controls. They were significantly worse than healthy controls in recognizing all auditory emotions except auditory emotion of fear (p = 0.067). The mean accuracy rates in recognizing video-based auditory/facial emotions of surprise (p = 0.031) and neutral (p = 0.029) emotions were significantly worse in children with CIs. Conclusion: The children with hearing loss were poorer in recognizing surprise, anger, and neutral facial emotions than healthy children; they had similar performance in recognizing anger emotions when both stimuli were given synchronously which may have a positive effect on social behaviors. It seems beneficial that emotion recognition training should be included in rehabilitation programs.
- 11 August 2021
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 27 (2) , 133-138
Facial and Auditory Recognition Abilities of Implanted Primary Schoolers
Objective: Emotions are often conveyed via visual and together with the auditory mode in social interaction. We aimed to investigate the ability to recognize facial and/or auditory emotions in school-aged children with cochlear implantation and healthy controls. Methods: All participants were asked to respond to facial emotions of Ekman and Friesen’s pictures, then auditory emotions, and last, they were asked to respond to video-based dynamic synchronous facial and auditory emotions. Results: The mean accuracy rates in recognizing anger (p = 0.025), surprise (p = 0.029), and neutral (p = 0.029) faces were significantly worse in children with cochlear implants (CIs) than in healthy controls. They were significantly worse than healthy controls in recognizing all auditory emotions except auditory emotion of fear (p = 0.067). The mean accuracy rates in recognizing video-based auditory/facial emotions of surprise (p = 0.031) and neutral (p = 0.029) emotions were significantly worse in children with CIs. Conclusion: The children with hearing loss were poorer in recognizing surprise, anger, and neutral facial emotions than healthy children; they had similar performance in recognizing anger emotions when both stimuli were given synchronously which may have a positive effect on social behaviors. It seems beneficial that emotion recognition training should be included in rehabilitation programs.