Kostiantyn Karpenko
Kostiantyn Karpenko has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Oleksandr Salenko
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
5 shared publications - Viktor A. Chernyak
Taras Shevchenko National University of Kyiv, Kyiv, Ukraine
4 shared publications - Viktor Cherniak
Taras Shevchenko National University of Kyiv
4 shared publications - Vadym Orel
Zhytomyr Polytechnic State University
3 shared publications - Bohdan Salenko
Yuriy Kondratyuk Poltava Technical University
2 shared publications - Dmytro Dubenko
Bogomolets National Medical University, Kyiv
2 shared publications
Latest Publications
- 8 January 2026
- Published by Opca bolnica Zadar in Medica Jadertina
- Vol. 55 (3-4) , 211-218
Detection of Foreign Bodies in Simulated Wounds Using the Acoustic Emission Method
Introduction: Shrapnel and ballistic injuries are common in modern warfare, with many foreign bodies (FBs) undetectable by conventional imaging methods like X-ray or MRI. There is a critical need for a reliable, portable, and radiation-free method to detect radiolucent FBs in soft tissues, particularly in resource-limited or battlefield conditions. Methods: We developed and tested a prototype device using the Acoustic Emission (AE) method, which detects transient elastic waves generated when a flexible probe contacts a foreign object. Simulated wound channels were created in bovine muscle tissue, embedding fragments of metal, plastic, glass, and stone. Signals were captured with a microphone, analyzed with spectral tools and Fourier decomposition, and evaluated using fuzzy logic algorithms. Multiple probe configurations and contact conditions were evaluated. Results: Fragments ≥2.5 mm were detected with >50% accuracy; metal fragments ≥5.0 mm reached 80% accuracy. The detection of plastic fragments was least reliable. Glass and stone fragments showed moderate accuracy that increased with size. Short probes (300 mm, 5.2 mm diameter) produced the most consistent and clear signals. Signal analysis revealed that frequency spectrum width, rather than amplitude, correlated best with fragment type and size. Signal-to-noise ratios improved with gain adjustments and optimized filters. Conclusion: The AE method shows promise as a diagnostic tool for identifying foreign bodies, including radiolucent fragments, in wound channels. The technique offers a low-cost, portable, and radiation-free alternative suitable for field and emergency use. Further development and clinical validation could improve early detection and management of shrapnel injuries in both military and civilian settings.
- 8 January 2026
- Published by Opca bolnica Zadar in Medica Jadertina
- Vol. 55 (3-4) , 211-218
Detection of Foreign Bodies in Simulated Wounds Using the Acoustic Emission Method
Introduction: Shrapnel and ballistic injuries are common in modern warfare, with many foreign bodies (FBs) undetectable by conventional imaging methods like X-ray or MRI. There is a critical need for a reliable, portable, and radiation-free method to detect radiolucent FBs in soft tissues, particularly in resource-limited or battlefield conditions. Methods: We developed and tested a prototype device using the Acoustic Emission (AE) method, which detects transient elastic waves generated when a flexible probe contacts a foreign object. Simulated wound channels were created in bovine muscle tissue, embedding fragments of metal, plastic, glass, and stone. Signals were captured with a microphone, analyzed with spectral tools and Fourier decomposition, and evaluated using fuzzy logic algorithms. Multiple probe configurations and contact conditions were evaluated. Results: Fragments ≥2.5 mm were detected with >50% accuracy; metal fragments ≥5.0 mm reached 80% accuracy. The detection of plastic fragments was least reliable. Glass and stone fragments showed moderate accuracy that increased with size. Short probes (300 mm, 5.2 mm diameter) produced the most consistent and clear signals. Signal analysis revealed that frequency spectrum width, rather than amplitude, correlated best with fragment type and size. Signal-to-noise ratios improved with gain adjustments and optimized filters. Conclusion: The AE method shows promise as a diagnostic tool for identifying foreign bodies, including radiolucent fragments, in wound channels. The technique offers a low-cost, portable, and radiation-free alternative suitable for field and emergency use. Further development and clinical validation could improve early detection and management of shrapnel injuries in both military and civilian settings.
- Open Access
- 20 March 2025
- Published by State Institution of Science "Center of Innovative Healthcare Technologies" State Administrative Department in Clinical and Preventive Medicine
- No. 3,p. 121-128
DETECTION OF METALLIC AND NON-METALLIC ORIGIN FOREIGN BODIES IN BIOLOGICAL TISSUES OBTAINED AS A RESULT OF MILITARY TRAUMA: A LITERATURE REVIEW
Introduction. The presence of foreign bodies in the human body is often the result of injuries with a violation of the integrity of the integumentary structures. In combat conditions, fragments of metal, glass or other materials can enter the body, which complicates diagnosis. Metal objects are well visualized on radiography and CT, but non-metallic materials, such as wood or plastic, require the use of other imaging methods, such as ultrasound or MRI. Increasing the sensitivity of detection methods is an important task of modern medicine. A separate important issue in the detection of foreign bodies (FB) is their intraoperative detection and navigation. Removal of a foreign body resulting from combat trauma is often a complex technical task that requires special skills of the surgeon and high-tech medical equipment that can be used during surgical intervention. Such equipment must meet medical safety standards, be mobile and convenient to use, and must be resistant to multiple sterilizations and exposure to aggressive chemicals and biological fluids. Aim. Analysis of modern approaches and technologies for detecting foreign bodies of metallic and non-metallic origin in biological tissues resulting from combat trauma. Results and discussion. Various imaging methods can be used to detect foreign objects, such as ultrasound, conventional radiography, computed tomography, or magnetic resonance imaging. The visibility of foreign bodies depends on the interaction of the physicochemical properties of the object and the physical phenomena underlying the corresponding imaging method. The currently accepted methods are the main tools for diagnosing FB, each of which has its own advantages and limitations. For accurate planning of surgical interventions, it is necessary to use radiography, ultrasound, CT, or MRI, depending on the situation. In the case of complex injuries, intraoperative navigation should be used to localize the FB and minimize the risk of complications. Conclusions. Development of new imaging techniques: Development of non-radioactive fragments detection in gunshot wounds using noise emission technology, imaging and intraoperative navigation will increase the efficiency of detection and treatment of patients with FB.
- 20 March 2025
- Published by State Institution of Science "Center of Innovative Healthcare Technologies" State Administrative Department in Clinical and Preventive Medicine
- No. 3,p. 121-128
Open AccessDETECTION OF METALLIC AND NON-METALLIC ORIGIN FOREIGN BODIES IN BIOLOGICAL TISSUES OBTAINED AS A RESULT OF MILITARY TRAUMA: A LITERATURE REVIEW
Introduction. The presence of foreign bodies in the human body is often the result of injuries with a violation of the integrity of the integumentary structures. In combat conditions, fragments of metal, glass or other materials can enter the body, which complicates diagnosis. Metal objects are well visualized on radiography and CT, but non-metallic materials, such as wood or plastic, require the use of other imaging methods, such as ultrasound or MRI. Increasing the sensitivity of detection methods is an important task of modern medicine. A separate important issue in the detection of foreign bodies (FB) is their intraoperative detection and navigation. Removal of a foreign body resulting from combat trauma is often a complex technical task that requires special skills of the surgeon and high-tech medical equipment that can be used during surgical intervention. Such equipment must meet medical safety standards, be mobile and convenient to use, and must be resistant to multiple sterilizations and exposure to aggressive chemicals and biological fluids. Aim. Analysis of modern approaches and technologies for detecting foreign bodies of metallic and non-metallic origin in biological tissues resulting from combat trauma. Results and discussion. Various imaging methods can be used to detect foreign objects, such as ultrasound, conventional radiography, computed tomography, or magnetic resonance imaging. The visibility of foreign bodies depends on the interaction of the physicochemical properties of the object and the physical phenomena underlying the corresponding imaging method. The currently accepted methods are the main tools for diagnosing FB, each of which has its own advantages and limitations. For accurate planning of surgical interventions, it is necessary to use radiography, ultrasound, CT, or MRI, depending on the situation. In the case of complex injuries, intraoperative navigation should be used to localize the FB and minimize the risk of complications. Conclusions. Development of new imaging techniques: Development of non-radioactive fragments detection in gunshot wounds using noise emission technology, imaging and intraoperative navigation will increase the efficiency of detection and treatment of patients with FB.
- Open Access
- 18 March 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Mechanics and Advanced Technologies
- Vol. 9 (1(104)) , 40-50
Increasing the sensitivity of the tactile sensor to detect shredders in the patient’s body
Means of increasing the sensitivity of a tactile sensor for detecting foreign bodies in the wound of patients, the wound channel, which is advisable to use in field conditions in emergency situations, have been analyzed. Such a sensor is a device consisting of a probe and a block of mechanical and electronic means held by the paramedic's hand. To detect a foreign body, a probe containing an elastic thin flexible probe with an external quasi-elastic shell is inserted through the wound channel until contact with the foreign body. The signal from the dynamic contact is visualized and displayed on a display device, which allows the paramedic to make a decision on further medical care for the affected person.Since the probe receives additional mechanical excitation, the signal has a long-lasting form, which increases the efficiency of primary diagnostics. However, at the same time, using the probe as a waveguide for both mechanical excitation and for transmitting vibrations to the means of amplification and spectral analysis significantly distorts the informativeness of the signal, impairs the accuracy of the studies.It is proposed to use the probe shell as a waveguide for transmitting vibrations, while the probe acts directly as a waveguide for the contact signal.It has been established that in this case it is possible to increase the signal-to-noise ratio in the range of 0.92…2.5 kHz to 2 dBA, which is extremely important for analyzing the spectral density patterns of vibrations from contact conditions in a viscous medium.
- 18 March 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Mechanics and Advanced Technologies
- Vol. 9 (1(104)) , 40-50
Open AccessIncreasing the sensitivity of the tactile sensor to detect shredders in the patient’s body
Means of increasing the sensitivity of a tactile sensor for detecting foreign bodies in the wound of patients, the wound channel, which is advisable to use in field conditions in emergency situations, have been analyzed. Such a sensor is a device consisting of a probe and a block of mechanical and electronic means held by the paramedic's hand. To detect a foreign body, a probe containing an elastic thin flexible probe with an external quasi-elastic shell is inserted through the wound channel until contact with the foreign body. The signal from the dynamic contact is visualized and displayed on a display device, which allows the paramedic to make a decision on further medical care for the affected person.Since the probe receives additional mechanical excitation, the signal has a long-lasting form, which increases the efficiency of primary diagnostics. However, at the same time, using the probe as a waveguide for both mechanical excitation and for transmitting vibrations to the means of amplification and spectral analysis significantly distorts the informativeness of the signal, impairs the accuracy of the studies.It is proposed to use the probe shell as a waveguide for transmitting vibrations, while the probe acts directly as a waveguide for the contact signal.It has been established that in this case it is possible to increase the signal-to-noise ratio in the range of 0.92…2.5 kHz to 2 dBA, which is extremely important for analyzing the spectral density patterns of vibrations from contact conditions in a viscous medium.
- Open Access
- 1 January 2024
- Published by Taras Shevchenko National University of Kyiv in Medical physics – the current status, problems, the way of development. Innovation technologies
- No. 1,p. 313-320
DEVELOPMENT OF A DEVICE FOR THE DETECTION OF NON-X-RAY CONTRAST FRAGMENTS IN THE WOUNDED AFTER BURNT INJURIES
Introduction. Since the injury often occurs not only with radiopaque fragments and bullets, the diagnosis of the position of foreign bodies in the wound channel or the patient's cavity is complicated. In the conditions of modern conflict, new types of weapons and striking projectiles are used, and new materials, in particular modifications of plastic, are increasingly used as bullets, projectile shells, and offensive and defensive grenades. Cases of splinter damage to soft tissues by plastic and glass elements are increasingly common. Plastic, getting into the human body's soft tissues, has the properties of the cores of bursting bullets, significantly increasing the size of the pulsating cavity of the wound channel. At the same time, the ability of plastic and glass to shatter in the body may require opening wounds to treat and remove these foreign objects, increasing the trauma and prolonging the rehabilitation period of patients. Searching for a fragment, especially a non-radiocontrast one, in the wound channel is often difficult and long, which is associated with its insufficient visualization, a change in the normal anatomy in gunshot wounds, and the difficulty of the surgical search. Therefore, the search for simple and reliable means of diagnosing foreign objects in the patient's body (without the use of X-ray machines) in the field is an urgent and extremely important task today, the solution of which can save the lives and health of thousands of wounded. Conclusions. The article describes the prerequisites for the development of a new method of diagnosing the presence of extraneous non-contrast fragments in a patient's wound through direct contact. The use of the noise emission effect is described for the detection of fragments. Due to the difference in noise, it is possible to tactilely diagnose the location of the fragment. After experimenting with the biological model, it was possible to record the dependence of the amplitude and base frequency of oscillations depending on the position of the fragment and its size in the wound channel. The article also provides an example of an effective pain relief scheme when searching for fragments.
- 1 January 2024
- Published by Taras Shevchenko National University of Kyiv in Medical physics – the current status, problems, the way of development. Innovation technologies
- No. 1,p. 313-320
Open AccessDEVELOPMENT OF A DEVICE FOR THE DETECTION OF NON-X-RAY CONTRAST FRAGMENTS IN THE WOUNDED AFTER BURNT INJURIES
Introduction. Since the injury often occurs not only with radiopaque fragments and bullets, the diagnosis of the position of foreign bodies in the wound channel or the patient's cavity is complicated. In the conditions of modern conflict, new types of weapons and striking projectiles are used, and new materials, in particular modifications of plastic, are increasingly used as bullets, projectile shells, and offensive and defensive grenades. Cases of splinter damage to soft tissues by plastic and glass elements are increasingly common. Plastic, getting into the human body's soft tissues, has the properties of the cores of bursting bullets, significantly increasing the size of the pulsating cavity of the wound channel. At the same time, the ability of plastic and glass to shatter in the body may require opening wounds to treat and remove these foreign objects, increasing the trauma and prolonging the rehabilitation period of patients. Searching for a fragment, especially a non-radiocontrast one, in the wound channel is often difficult and long, which is associated with its insufficient visualization, a change in the normal anatomy in gunshot wounds, and the difficulty of the surgical search. Therefore, the search for simple and reliable means of diagnosing foreign objects in the patient's body (without the use of X-ray machines) in the field is an urgent and extremely important task today, the solution of which can save the lives and health of thousands of wounded. Conclusions. The article describes the prerequisites for the development of a new method of diagnosing the presence of extraneous non-contrast fragments in a patient's wound through direct contact. The use of the noise emission effect is described for the detection of fragments. Due to the difference in noise, it is possible to tactilely diagnose the location of the fragment. After experimenting with the biological model, it was possible to record the dependence of the amplitude and base frequency of oscillations depending on the position of the fragment and its size in the wound channel. The article also provides an example of an effective pain relief scheme when searching for fragments.
- Open Access
- 29 December 2023
- Published by Publishing Company VIT-A-POL in General Surgery
- No. 3-4,p. 61-67
Endovascular treatment of post-thrombotic syndrome of the lower extremities caused by combat trauma. Clinical case
In the course of Russia’s military invasion of Ukraine, gunshot shrapnel wounds of the lower extremities that result in damage to major blood vessels have become a common phenomenon. Their incidence is consistent with the general data on combat‑related vascular injuries. Vascular gunshot injuries can cause significant changes to the normal anatomy and hemodynamics of the extremity as a result of the bullet or shrapnel travelling through the wound channel. Combat trauma of the vascular bundle, either as a primary factor or in combination with other lesions, often causes a serious condition in the wounded that requires urgent surgical intervention]. Injury to the major blood vessels of the lower limbs carries the risk of critical ischemia, which can lead to higher mortality rates, poor limb recovery, and disability. This clinical case demonstrates the endovascular management of a disabling combat‑related vascular injury. The treatment involves the use of modern imaging techniques and minimally invasive surgical procedures. This case highlights the progression of the pathological process after a gunshot shrapnel wound to the soft tissues and major blood vessels. It also shows a change in the normal anatomy of the major blood vessels and the subsequent development of regional hemodynamic disorders of the lower limb after injury. In January 2023, a 51‑year‑old male received a gunshot wound to the soft tissues of the pelvis and right lower limb, as well as a gunshot fracture of the right femur. Immediate post‑evacuation therapy included the management of life‑threatening bleeding by ligating the deep femoral artery and providing external fixation of the gunshot femur fracture. Following the healing of the wounds and the removal of the external fixation device, the injured individual experienced a progressive and notable swelling of the lower limb over a period of 3 months. Subsequently, trophic ulcers appeared on the lower leg. In September 2023, the patient was admitted to the National Military Medical Clinical Centre in Kyiv after developing clinical signs of the post‑thrombotic syndrome. However, further examination revealed the presence of an AV fistula. Consequently, a simultaneous endovascular reconstructive intervention was performed on the arteries and veins of the patient’s lower extremity. Conclusions. A gunshot wound to the major blood vessels can contribute to pathological changes in the normal anatomical structure, resulting in arterial collateral blood circulation or narrowing of blood vessels that can lead to regional hemodynamic disorders. The clinical case exemplifies the importance of using modern imaging techniques for a comprehensive examination of the vascular system and the possibility of minimally invasive treatment for patients with gunshot injuries to the major blood vessels.
- 29 December 2023
- Published by Publishing Company VIT-A-POL in General Surgery
- No. 3-4,p. 61-67
Open AccessEndovascular treatment of post-thrombotic syndrome of the lower extremities caused by combat trauma. Clinical case
In the course of Russia’s military invasion of Ukraine, gunshot shrapnel wounds of the lower extremities that result in damage to major blood vessels have become a common phenomenon. Their incidence is consistent with the general data on combat‑related vascular injuries. Vascular gunshot injuries can cause significant changes to the normal anatomy and hemodynamics of the extremity as a result of the bullet or shrapnel travelling through the wound channel. Combat trauma of the vascular bundle, either as a primary factor or in combination with other lesions, often causes a serious condition in the wounded that requires urgent surgical intervention]. Injury to the major blood vessels of the lower limbs carries the risk of critical ischemia, which can lead to higher mortality rates, poor limb recovery, and disability. This clinical case demonstrates the endovascular management of a disabling combat‑related vascular injury. The treatment involves the use of modern imaging techniques and minimally invasive surgical procedures. This case highlights the progression of the pathological process after a gunshot shrapnel wound to the soft tissues and major blood vessels. It also shows a change in the normal anatomy of the major blood vessels and the subsequent development of regional hemodynamic disorders of the lower limb after injury. In January 2023, a 51‑year‑old male received a gunshot wound to the soft tissues of the pelvis and right lower limb, as well as a gunshot fracture of the right femur. Immediate post‑evacuation therapy included the management of life‑threatening bleeding by ligating the deep femoral artery and providing external fixation of the gunshot femur fracture. Following the healing of the wounds and the removal of the external fixation device, the injured individual experienced a progressive and notable swelling of the lower limb over a period of 3 months. Subsequently, trophic ulcers appeared on the lower leg. In September 2023, the patient was admitted to the National Military Medical Clinical Centre in Kyiv after developing clinical signs of the post‑thrombotic syndrome. However, further examination revealed the presence of an AV fistula. Consequently, a simultaneous endovascular reconstructive intervention was performed on the arteries and veins of the patient’s lower extremity. Conclusions. A gunshot wound to the major blood vessels can contribute to pathological changes in the normal anatomical structure, resulting in arterial collateral blood circulation or narrowing of blood vessels that can lead to regional hemodynamic disorders. The clinical case exemplifies the importance of using modern imaging techniques for a comprehensive examination of the vascular system and the possibility of minimally invasive treatment for patients with gunshot injuries to the major blood vessels.
- Open Access
- 22 December 2023
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Mechanics and Advanced Technologies
- Vol. 7 (3 (99)) , 337-349
The possibility of detecting non-x-ray fragments in the body of the wounded by the contact method
The types of injuries and types of striking elements were analyzed, the conditions of patients requiring urgent surgical intervention were assessed. The possibilities of existing means of diagnosing fragments in the patient's body were analyzed, and it was concluded that for non-X-ray contrast fragments, the proposed method of mechanical contact with a special flexible and elastic probe is appropriate and effective.A special tool for examining wound canals has been developed, consisting of a flexible probe for individual use and a handle-holder with a microphone capsule, the membrane of which is directly connected to the probe and reacts to mechanical contact with an obstacle, and the capsule itself is directly connected to the oscilloscope through a signal amplifier . which has spectral signal processing circuits.The problem of the interaction of the elastic contact of a non-rigid element with a fragment located in a viscous medium is set, provided that the properties of the medium are not constant. Typical solutions of this problem for various types of fragments and parameters of the contacting element itself are presented. A picture of the noise emission accompanying the contact is shown.The functional dependence of noise emission parameters on the shape and type of the foreign object in the wound canal was revealed. The expediency of using the frequency-amplitude characteristic of noise radiation as a controlled parameter has been proven. A conclusion was made about the functional conditioning of the width of the signal spectrum and basic frequencies at the time of mechanical contact with a foreign object in the wound, depending on its shape and type; it was established that the use of an oscilloscope with a spectral analysis channel allows for the fairly accurate identification of a non-radiocontrast foreign object in a wound.
- 22 December 2023
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Mechanics and Advanced Technologies
- Vol. 7 (3 (99)) , 337-349
Open AccessThe possibility of detecting non-x-ray fragments in the body of the wounded by the contact method
The types of injuries and types of striking elements were analyzed, the conditions of patients requiring urgent surgical intervention were assessed. The possibilities of existing means of diagnosing fragments in the patient's body were analyzed, and it was concluded that for non-X-ray contrast fragments, the proposed method of mechanical contact with a special flexible and elastic probe is appropriate and effective.A special tool for examining wound canals has been developed, consisting of a flexible probe for individual use and a handle-holder with a microphone capsule, the membrane of which is directly connected to the probe and reacts to mechanical contact with an obstacle, and the capsule itself is directly connected to the oscilloscope through a signal amplifier . which has spectral signal processing circuits.The problem of the interaction of the elastic contact of a non-rigid element with a fragment located in a viscous medium is set, provided that the properties of the medium are not constant. Typical solutions of this problem for various types of fragments and parameters of the contacting element itself are presented. A picture of the noise emission accompanying the contact is shown.The functional dependence of noise emission parameters on the shape and type of the foreign object in the wound canal was revealed. The expediency of using the frequency-amplitude characteristic of noise radiation as a controlled parameter has been proven. A conclusion was made about the functional conditioning of the width of the signal spectrum and basic frequencies at the time of mechanical contact with a foreign object in the wound, depending on its shape and type; it was established that the use of an oscilloscope with a spectral analysis channel allows for the fairly accurate identification of a non-radiocontrast foreign object in a wound.
- Open Access
- 30 August 2023
- Published by Ukrainian Research and Design Institute of Building Materials and Products in SWorld-Ger Conference proceedings
- No. gec40-00,p. 71-75
SURGICAL TREATMENT OF A GUNSHOT WOUND WITH A FOREIGN BODY: USING THE SENSITIVITY OF THE TACTILE SENSOR
Despite the obvious advantages of ultrasound devices, in field conditions, especially during the primary surgical treatment of gunshot wounds in patients affected by shrapnel, the device we offer has undeniable advantages, since it does not require highly
- 30 August 2023
- Published by Ukrainian Research and Design Institute of Building Materials and Products in SWorld-Ger Conference proceedings
- No. gec40-00,p. 71-75
Open AccessSURGICAL TREATMENT OF A GUNSHOT WOUND WITH A FOREIGN BODY: USING THE SENSITIVITY OF THE TACTILE SENSOR
Despite the obvious advantages of ultrasound devices, in field conditions, especially during the primary surgical treatment of gunshot wounds in patients affected by shrapnel, the device we offer has undeniable advantages, since it does not require highly
- Open Access
- 30 August 2023
- Published by Ukrainian Research and Design Institute of Building Materials and Products in SWorld-Ger Conference proceedings
- No. gec34-00,p. 48-57
SOUND METHODS OF DETECTING FRAGMENTS IN THE WOUND
The work considers the search for simple and reliable means of diagnosing foreign objects in the patient's body without the use of X-ray machines. The main methods of such diagnostics include ultrasound, but it requires the use of a special immersion liqu
- 30 August 2023
- Published by Ukrainian Research and Design Institute of Building Materials and Products in SWorld-Ger Conference proceedings
- No. gec34-00,p. 48-57
Open AccessSOUND METHODS OF DETECTING FRAGMENTS IN THE WOUND
The work considers the search for simple and reliable means of diagnosing foreign objects in the patient's body without the use of X-ray machines. The main methods of such diagnostics include ultrasound, but it requires the use of a special immersion liqu
- Open Access
- 28 December 2022
- Published by Communicable Diseases Intensive Care Association in Infusion & Chemotherapy
- No. 4,p. 46-51
Features of the influence of degenerative changes of the cervical spine in the V1 segment of the spinal artery on the character of extravasal compression
BACKGROUND. The peculiarity of the cervical spine (CS) is a complex movable musculoskeletal, ligamentous-articular apparatus that carries a significant static and dynamic load. X-ray research methods could not based on the definition of degenerative changes in bones and joints, explain compression-reflex and myotonic syndromes in the pathology of the CS. OBJECTIVE. To reveal the clinical, instrumental, and hemodynamic features of the course of vertebral artery compression syndrome (VACS) and their role in determining diagnostic and therapeutic tactics. MATERIALS AND METHODS. The features of diagnosis and treatment tactics of 1,118 patients with degenerative lesions of the CS and VACS were analyzed. X-ray examination made it possible to solve common tasks of diagnosis. During the analysis of X-ray examination in segment V1 showed degeneration of dystrophic changes. RESULTS AND DISCUSSION. Analyzing the expressiveness of VACS in compression scores, we obtained the following results for the identified variants of dystrophic changes of VACS in the projection of the V1 segment: variant I – 14.7±1.84; variant II – 15.3±1.72; variant III-A – 17.1±1.78; variant III-B – 16.2±1.67; variant IV-A – 16.8±1.69; variant IV-B – 15.9±1.48. The analysis of degenerative-dystrophic changes of the CS at the level of the maximum positional compression showed that the expressiveness of the extravasal positional compression in the V1 segment did not differ significantly in variants I, II, III. CONCLUSIONS. 1. Degenerative changes in CS occur long before the appearance of the clinical manifestation of VACS. 2. The expressiveness of the degenerative damage of the musculoskeletal system of the CS according to the X-ray examination does not correspond to the clinical course of VACS. 3. Character of radiological functional instability in CS is not reflected in the complex clinical symptoms of VACS. 4. A multimodal approach to analgesia guarantees full control over all links of the pain process.
- 28 December 2022
- Published by Communicable Diseases Intensive Care Association in Infusion & Chemotherapy
- No. 4,p. 46-51
Open AccessFeatures of the influence of degenerative changes of the cervical spine in the V1 segment of the spinal artery on the character of extravasal compression
BACKGROUND. The peculiarity of the cervical spine (CS) is a complex movable musculoskeletal, ligamentous-articular apparatus that carries a significant static and dynamic load. X-ray research methods could not based on the definition of degenerative changes in bones and joints, explain compression-reflex and myotonic syndromes in the pathology of the CS. OBJECTIVE. To reveal the clinical, instrumental, and hemodynamic features of the course of vertebral artery compression syndrome (VACS) and their role in determining diagnostic and therapeutic tactics. MATERIALS AND METHODS. The features of diagnosis and treatment tactics of 1,118 patients with degenerative lesions of the CS and VACS were analyzed. X-ray examination made it possible to solve common tasks of diagnosis. During the analysis of X-ray examination in segment V1 showed degeneration of dystrophic changes. RESULTS AND DISCUSSION. Analyzing the expressiveness of VACS in compression scores, we obtained the following results for the identified variants of dystrophic changes of VACS in the projection of the V1 segment: variant I – 14.7±1.84; variant II – 15.3±1.72; variant III-A – 17.1±1.78; variant III-B – 16.2±1.67; variant IV-A – 16.8±1.69; variant IV-B – 15.9±1.48. The analysis of degenerative-dystrophic changes of the CS at the level of the maximum positional compression showed that the expressiveness of the extravasal positional compression in the V1 segment did not differ significantly in variants I, II, III. CONCLUSIONS. 1. Degenerative changes in CS occur long before the appearance of the clinical manifestation of VACS. 2. The expressiveness of the degenerative damage of the musculoskeletal system of the CS according to the X-ray examination does not correspond to the clinical course of VACS. 3. Character of radiological functional instability in CS is not reflected in the complex clinical symptoms of VACS. 4. A multimodal approach to analgesia guarantees full control over all links of the pain process.
- Top Cited Papers
- 7 September 2022
- Published by Wiley in World Journal of Surgery
- Vol. 46 (12) , 2858-2862
Ukraine's Experience with Management of Combat Casualties Using NATO's Four‐Tier “Changing as Needed” Healthcare System
Introduction: The full‐scale war with Russia on the territory of Ukraine has revealed several problems related to care of the wounded. In this article, we summarize the mechanisms of injury and injuries sustained for the period February to April 2022, focusing on extremity injuries.Materials and methods: We compared these to a period of lower‐intensity warfare in 2014–2021. In both cases, we report patients treated by the National Military Medical Clinical Center (NMMCC) in Kyiv. We also sought to evaluate the care of the wounded from an organizational viewpoint, taking into account the four‐level system of care also used by the North Atlantic Treaty Organization (NATO). Third, we sought to understand lessons learned that could improve the care of the wounded.Conclusion: During the 2022 conflict, the percentage of patients with extremity wounds who had long bone fractures increased and the percentage of people with long bone fractures who had bone defects increased, compared with 2014–2021. This may be due to the higher blast energy from the weapons used in the current conflict. Second, we adapted the four‐level NATO system of care. Level 2 (first level hospital) care was provided by civilian hospitals close to the fighting, rather than mobile military hospitals. Level 3 (specialized) and 4 (highly specialized) care were combined into one hospital (NMMCC). This is the first description of flexible use of NATO's four levels. Finally, a major lesson learned was the need to improve use of damage control surgery.
- 7 September 2022
- Published by Wiley in World Journal of Surgery
- Vol. 46 (12) , 2858-2862
Top Cited PapersUkraine's Experience with Management of Combat Casualties Using NATO's Four‐Tier “Changing as Needed” Healthcare System
Introduction: The full‐scale war with Russia on the territory of Ukraine has revealed several problems related to care of the wounded. In this article, we summarize the mechanisms of injury and injuries sustained for the period February to April 2022, focusing on extremity injuries.Materials and methods: We compared these to a period of lower‐intensity warfare in 2014–2021. In both cases, we report patients treated by the National Military Medical Clinical Center (NMMCC) in Kyiv. We also sought to evaluate the care of the wounded from an organizational viewpoint, taking into account the four‐level system of care also used by the North Atlantic Treaty Organization (NATO). Third, we sought to understand lessons learned that could improve the care of the wounded.Conclusion: During the 2022 conflict, the percentage of patients with extremity wounds who had long bone fractures increased and the percentage of people with long bone fractures who had bone defects increased, compared with 2014–2021. This may be due to the higher blast energy from the weapons used in the current conflict. Second, we adapted the four‐level NATO system of care. Level 2 (first level hospital) care was provided by civilian hospitals close to the fighting, rather than mobile military hospitals. Level 3 (specialized) and 4 (highly specialized) care were combined into one hospital (NMMCC). This is the first description of flexible use of NATO's four levels. Finally, a major lesson learned was the need to improve use of damage control surgery.