XTXinxin Tang

Xinxin Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xinxin Tang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Active thermal balancing strategy of three-level converters through stray parameters control in laminated busbars

    by Xinxin Tang, Wei Li, Yaming Xu

    In high-power three-level converters, busbar stray inductance critically influences switching transient and thermal distribution. This paper establishes a parametric stray inductance model for laminated busbars and analyses its impact on commutation paths. To resolve thermal imbalance, a power loss thermal balance method optimizes control strategies, enabling stable commutation path switching and preventing system instability at switching points. The key is to propose weighting factors based on stray parameters for dynamic energy exchange among internal, external and clamp switches, combined with case temperature-dependent modulation to achieve thermal balance in three-level converters. The accuracy of the model established and the feasibility of the adopted approach are verified by simulation studies in MATLAB/Simulink and experiments based on a 900 V alternating current power system.

  • Three-Level SiC DC–DC Converter With Midpoint Voltage Self-Recovery for Energy-Storage Trams

    by Wei Li, Wenlu Zhang, Chunyang Chen, Xinxin Tang, Yejun Mao, Kai Wang

    The energy storage tram places high-quality requirements on the power supply system of energy storage devices. The charging system for the energy storage tram must deliver high voltage and high power to meet the demands of fast charging. The adoption of three-level DC-DC converters and wide-bandwidth devices, like SiC MOSFETs, expands the range of blocking voltage and switching frequency, making them highly suitable for high-voltage and high-power applications. To achieve a lightweight charging system, this paper proposes a three-level asymmetric hybrid clamped DC-DC converter. The operating principles and input midpoint voltage self-recovery mechanism are introduced. By employing a ’series charging and parallel discharging’ circuit configuration, midpoint voltage balance can be achieved under specific conditions. A charging control algorithm is designed to meet the charging requirements of energy storage trams. Based on this topology, a prototype charging module utilizing SiC MOSFET devices was developed. Compared to the previous generation of charging systems, this module has reduced volume by 32.85% and mass by 30.70%. Simulation and prototype experimental results validate the self-recovery capability of the midpoint voltage under specific conditions and demonstrate the effectiveness of the proposed control strategy.

  • Suppression Strategy for Midpoint Potential Fluctuation of Three-Level Wind Power Converter

    by Xinxin Tang, Yongqi Tang, Yaming Xu

    With the development of offshore wind power, three-level wind power converters have begun to be widely used in wind farms, but there has always been a problem of low-frequency fluctuations in bus voltage, which will seriously affect the power quality of wind farms. This article studies a genetic algorithm-back propagation (GA-BP) neural network optimization control method, injecting zero-sequence components on the basis of the sine pulsewidth modulation strategy of carrier stacking, and then optimizing the neural network weights and thresholds through genetic algorithm, and the bus capacitor voltage low-frequency fluctuations are tracked and compensated to improve the predictive ability of the control system. This combination of zero-sequence voltage injection and injection-compensated low-frequency fluctuation components solves the problem of bus voltage fluctuations. Through MATLAB/Simulink simulation analysis and 1140 V wind power converter experimental verification, the verification results show that the bus voltage fluctuation is reduced by 50%, and the grid current waveform is improved. The proposed scheme can well solve some of the influences caused by the fluctuation of the bus voltage in the wind power converter, ensure the operation reliability of the wind power system and improve the operation efficiency of the wind power system.