PGPietro Giampa

Pietro Giampa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pietro Giampa has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterisation of SiPM Photon Emission in the Dark

    by Joseph Biagio McLaughlin, Giacomo Gallina, Fabrice Retière, Austin De St. Croix, Pietro Giampa, Mahsa Mahtab, Peter Margetak, Lars Martin, Nicolas Massacret, Jocelyn Monroe, et al.

    In this paper, we report on the photon emission of Silicon Photomultipliers (SiPMs) from avalanche pulses generated in dark conditions, with the main objective of better understanding the associated systematics for next-generation, large area, SiPM-based physics experiments. A new apparatus for spectral and imaging analysis was developed at TRIUMF and used to measure the light emitted by the two SiPMs considered as photo-sensor candidates for the nEXO neutrinoless double-beta decay experiment: one Fondazione Bruno Kessler (FBK) VUV-HD Low Field (LF) Low After Pulse (Low AP) (VUV-HD3) SiPM and one Hamamatsu Photonics K.K. (HPK) VUV4 Multi-Pixel Photon Counter (MPPC). Spectral measurements of their light emissions were taken with varying over-voltage in the wavelength range of 450–1020 nm. For the FBK VUV-HD3, at an over-voltage of 12.1±1.0 V, we measured a secondary photon yield (number of photons (γ) emitted per charge carrier (e−)) of (4.04±0.02)×10−6γ/e−. The emission spectrum of the FBK VUV-HD3 contains an interference pattern consistent with thin-film interference. Additionally, emission microscopy images (EMMIs) of the FBK VUV-HD3 show a small number of highly localized regions with increased light intensity (hotspots) randomly distributed over the SiPM surface area. For the HPK VUV4 MPPC, at an over-voltage of 10.7±1.0 V, we measured a secondary photon yield of (8.71±0.04)×10−6γ/e−. In contrast to the FBK VUV-HD3, the emission spectra of the HPK VUV4 did not show an interference pattern—likely due to a thinner surface coating. The EMMIs of the HPK VUV4 also revealed a larger number of hotspots compared to the FBK VUV-HD3, especially in one of the corners of the device. The photon yield reported in this paper may be limited if compared with the one reported in previous studies due to the measurement wavelength range, which is only up to 1020 nm.


  • On the DEAP-3600 resurfacing

    by P. Giampa

    The DEAP-3600 experiment is a single-phase detector that can hold up to 3600 kg of liquid argon to search for dark matter at SNOLAB in Sudbury Canada, 6800 ft. underground. The projected sensitivity to the spin-independent WIMP-nucleon cross-section is 10−46 cm2 for a WIMP mass of 100 GeV/c2. One of the primary background sources to the WIMP search are alpha decays occurring on the surface of the experiment, which only deposit a tiny fraction of their energy in the argon. The work reported here focuses on the development and operation of a custom designed robot, the Resurfacer, which was used to remove 500 micrometers from the inner-most layer of the detector’s acrylic cryostat, thus removing contaminations introduced during construction.