Rosa Mendaza-DeCal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rosa Mendaza-DeCal has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jesus Rodriguez-Quiros
Department of Animal Medicine and Surgery, School of Veterinary Medicine, Complutense University of Madrid, 28040 Madrid, Spain
7 shared publications Salvador Peso-Fernandez
ABAX Engineering Solutions, Villanueva de la Cañada, Madrid, 28691, Spain
5 shared publicationsJuan Carlos del Real-Romero
Institute for Research in Technology/Mechanical Engineering Dept., Universidad Pontificia Comillas, Alberto Aguilera, 25, 28015 Madrid, Spain
2 shared publicationsYolanda Ballesteros
Institute for Research in Technology/Mechanical Engineering Dept., Universidad Pontificia Comillas, Alberto Aguilera, 25, 28015 Madrid, Spain
2 shared publications- Concepción Rojo
Department of Anatomy and Embryology, School of Veterinary Medicine, University Complutense of Madrid, 28040 Madrid, Spain
1 shared publication - David Díaz-Regañón
Department of Animal Medicine and Surgery, College of Veterinary Medicine, Complutense University of Madrid, 28040 Madrid, Spain
1 shared publication
Latest Publications
- 13 June 2026
- Published by Springer Nature in Veterinary Research Communications
- Vol. 50 (5)
3D-printed peek exo-endoprosthesis for limb salvage in dogs and cats
Exo-endoprostheses are gradually gaining popularity in veterinary medicine. This study reports the clinical evolution of four patients -one feline and three canines- treated with a novel exo-endoprosthesis system. In all cases, distal limb amputation was performed due to various pathologies -type IIB open fracture, grade 1 chondrosarcoma, ectrodactyly and traumatic partial amputation-, followed by implantation of a custom-designed endomedullary component inserted into the residual bone during same surgical procedure. The interval before exoprosthesis attachment ranged from 2 to 5 months postoperatively, depending on patient-specific factors such as epithelial down-growth or external limitations. Different exoprosthesis designs and versions were developed and 3D-printed according to anatomical region of amputation. Surgical technique, postoperative outcome, limb function, and radiographic findings were described for each case. Upon initial attachment, all animals readily accepted exoprosthesis, with no instances of implant failure or fracture during use. Osseous growth with this inner part was consistent and robust across cases. Surgeries were free of intraoperative complications and postoperative pain. However, long-term use was limited by instability at exo-endoprosthesis interface, which prevented consistent weight-bearing and definitive prosthesis adoption. Postoperative complications included excessive skin overgrowth in patients 2 and 4, and delayed healing in patient 3. Key issues were suboptimal postoperative care and delays in iterative exoprosthesis adjustments. Clinical progress of this system was discussed and compared with analogous designs in human medicine. Internal part implantation of exo-endoprosthesis to distal limb of small animals is feasible and can result in favourable functional outcomes if dermal integration issue can be adequately addressed.
- 13 June 2026
- Published by Springer Nature in Veterinary Research Communications
- Vol. 50 (5)
3D-printed peek exo-endoprosthesis for limb salvage in dogs and cats
Exo-endoprostheses are gradually gaining popularity in veterinary medicine. This study reports the clinical evolution of four patients -one feline and three canines- treated with a novel exo-endoprosthesis system. In all cases, distal limb amputation was performed due to various pathologies -type IIB open fracture, grade 1 chondrosarcoma, ectrodactyly and traumatic partial amputation-, followed by implantation of a custom-designed endomedullary component inserted into the residual bone during same surgical procedure. The interval before exoprosthesis attachment ranged from 2 to 5 months postoperatively, depending on patient-specific factors such as epithelial down-growth or external limitations. Different exoprosthesis designs and versions were developed and 3D-printed according to anatomical region of amputation. Surgical technique, postoperative outcome, limb function, and radiographic findings were described for each case. Upon initial attachment, all animals readily accepted exoprosthesis, with no instances of implant failure or fracture during use. Osseous growth with this inner part was consistent and robust across cases. Surgeries were free of intraoperative complications and postoperative pain. However, long-term use was limited by instability at exo-endoprosthesis interface, which prevented consistent weight-bearing and definitive prosthesis adoption. Postoperative complications included excessive skin overgrowth in patients 2 and 4, and delayed healing in patient 3. Key issues were suboptimal postoperative care and delays in iterative exoprosthesis adjustments. Clinical progress of this system was discussed and compared with analogous designs in human medicine. Internal part implantation of exo-endoprosthesis to distal limb of small animals is feasible and can result in favourable functional outcomes if dermal integration issue can be adequately addressed.
- Open Access
Canine Upper Digestive Tract 3D Model: Assessing Its Utility for Anatomy and Upper Endoscopy Learning
A teaching strategy using 3D-printed models of the canine upper digestive tract (UDT) for anatomy demonstration and upper endoscopy instruction was evaluated. The canine UDT (esophagus–stomach–duodenum) was scanned and 3D-printed molds were manufactured using silicone casting. First-year students were introduced to these 3D models in practical sessions alongside real specimens. Simultaneously, fifth-year students were trained in endoscope handling and anatomical recognition using 3D specimens. Both groups completed an anonymous survey. Results showed that overall, first-year (n = 93) and fifth-year (n = 45) students agreed or strongly agreed that the 3D-printed model was effective for learning purposes. In summary, first-year students highlighted an improved understanding of size, volume, topography, and easier manipulation of the 3D model compared to fresh specimens. Fifth-year students were more enthusiastic, finding the 3D model valuable for spatial vision and clinical training. While both groups were against completely replacing the natural UDT with the 3D model, first-year students were more hesitant. These findings suggest that the 3D model of the canine UDT is an effective tool for hands-on training in clinical endoscopy and a valuable, albeit complementary, resource for teaching anatomy and topography.
Open AccessCanine Upper Digestive Tract 3D Model: Assessing Its Utility for Anatomy and Upper Endoscopy Learning
A teaching strategy using 3D-printed models of the canine upper digestive tract (UDT) for anatomy demonstration and upper endoscopy instruction was evaluated. The canine UDT (esophagus–stomach–duodenum) was scanned and 3D-printed molds were manufactured using silicone casting. First-year students were introduced to these 3D models in practical sessions alongside real specimens. Simultaneously, fifth-year students were trained in endoscope handling and anatomical recognition using 3D specimens. Both groups completed an anonymous survey. Results showed that overall, first-year (n = 93) and fifth-year (n = 45) students agreed or strongly agreed that the 3D-printed model was effective for learning purposes. In summary, first-year students highlighted an improved understanding of size, volume, topography, and easier manipulation of the 3D model compared to fresh specimens. Fifth-year students were more enthusiastic, finding the 3D model valuable for spatial vision and clinical training. While both groups were against completely replacing the natural UDT with the 3D model, first-year students were more hesitant. These findings suggest that the 3D model of the canine UDT is an effective tool for hands-on training in clinical endoscopy and a valuable, albeit complementary, resource for teaching anatomy and topography.
- Open Access
- 17 July 2023
- Published by Elsevier in Research in Veterinary Science
- Vol. 162, 104960
Orthotics and prosthetics by 3D-printing: Accelerating its fabrication flow
- 17 July 2023
- Published by Elsevier in Research in Veterinary Science
- Vol. 162, 104960
Open AccessOrthotics and prosthetics by 3D-printing: Accelerating its fabrication flow
- Open Access
- 17 April 2023
- Published by Elsevier in Research in Veterinary Science
- Vol. 159, 81-83
Short communication: Torsional tests on long-bone cylindrical medullary-canal exo-endoprostheses
- 17 April 2023
- Published by Elsevier in Research in Veterinary Science
- Vol. 159, 81-83
Open AccessShort communication: Torsional tests on long-bone cylindrical medullary-canal exo-endoprostheses
- Open Access
Biomechanical Tests on Long-Bone Elliptical Medullary-Canal Endoprostheses for Limb Salvage in Dogs
Exo-endoprosthesis is a limb salvage procedure poorly described for animals, as only expensive metal devices have been used so far. Currently, additive manufacturing (AM) can make this type of implant affordable by exploring a wide new range of materials. However, safety factors should be considered and could be related to kinetic and kinematic studies of canine natural gaits. The suitability of a novel inner part of an exo-endoprosthesis manufactured by fuse deposition modeling (FDM) was assessed for long canine bones with an elliptical medullary canal. Polyether ether ketone (PEEK) was the material used as an alternative to metal for veterinary traumatology. Poisson’s ratio of 3D-printed PEEK material and ex vivo mechanical tests of the customized endoprosthesis were performed for the evaluation. The customized endoprostheses had promising outcomes for the radii of 20 kg dogs. Quasistatic mechanical tests of bone-inserted endoprostheses—pure compression tests—reached a maximum force of 1045.0 ± 78.0 N. In fatigue tests, the samples reached 500,000 cycles without failure or detriment to their quasistatic results. These outcomes surpass the natural weight-bearing of dogs, even during a galloping pace. Furthermore, torque tests with different adhesives were performed to obtain reference data for future assessments comparing with natural dog movements.
Open AccessBiomechanical Tests on Long-Bone Elliptical Medullary-Canal Endoprostheses for Limb Salvage in Dogs
Exo-endoprosthesis is a limb salvage procedure poorly described for animals, as only expensive metal devices have been used so far. Currently, additive manufacturing (AM) can make this type of implant affordable by exploring a wide new range of materials. However, safety factors should be considered and could be related to kinetic and kinematic studies of canine natural gaits. The suitability of a novel inner part of an exo-endoprosthesis manufactured by fuse deposition modeling (FDM) was assessed for long canine bones with an elliptical medullary canal. Polyether ether ketone (PEEK) was the material used as an alternative to metal for veterinary traumatology. Poisson’s ratio of 3D-printed PEEK material and ex vivo mechanical tests of the customized endoprosthesis were performed for the evaluation. The customized endoprostheses had promising outcomes for the radii of 20 kg dogs. Quasistatic mechanical tests of bone-inserted endoprostheses—pure compression tests—reached a maximum force of 1045.0 ± 78.0 N. In fatigue tests, the samples reached 500,000 cycles without failure or detriment to their quasistatic results. These outcomes surpass the natural weight-bearing of dogs, even during a galloping pace. Furthermore, torque tests with different adhesives were performed to obtain reference data for future assessments comparing with natural dog movements.
- Open Access
- 30 June 2022
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 9, 887676
Biomechanical Test of a New Endoprosthesis for Cylindrical Medullary Canals in Dogs
Exo-endoprosthesis is a limb salvage procedure for animals, although only expensive metal devices have been described. Now-a-days, new materials for this type of implant could be considered due to novel and affordable manufacturing techniques. However, a factor of safety (FoS) should be considered. There are kinetic and kinematic studies of canine natural gaits, which can be used to establish an FoS for mechanical tests for new non-metallic devices. Polyetheretherketone (PEEK) is used in different specialties in human medicine. Its mechanical properties (and its close mechanical stiffness to that of bone) make this polymer an alternative to metals in veterinary traumatology. PEEK could also be used in 3D printing. The suitability of a novel inner part of an exo-endoprosthesis manufactured by fuse deposition modeling (FDM) was presented in this study for long canine bones. Mechanical characterization of 3D-printed PEEK material and ex vivo mechanical tests of a customized endoprosthesis were performed to address it. Young's modulus of 3D-printed PEEK suffered a reduction of 30% in relation to bulk PEEK. Customized 3D-printed PEEK endoprostheses had promising outcomes for the tibiae of 20 kg dogs. Pure compression tests of the non-inserted endoprostheses showed a maximum force of 936 ± 199 N. In the bending tests of non-inserted endoprostheses, the PEEK part remained intact. Quasistatic mechanical tests of bone-inserted endoprostheses (compression-bending and pure compression tests) reached a maximum force of 785 ± 101 N and 1,642 ± 447 N, respectively. In fatigue tests, the samples reached 500,000 cycles without failure or detriment to their quasistatic results. These outcomes surpass the natural weight-bearing of dogs, even during a galloping pace. In conclusion, the 3D-printed PEEK part of the endoprosthesis for an exo-endoprosthesis can withstand loading, even during a galloping pace.
- 30 June 2022
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 9, 887676
Open AccessBiomechanical Test of a New Endoprosthesis for Cylindrical Medullary Canals in Dogs
Exo-endoprosthesis is a limb salvage procedure for animals, although only expensive metal devices have been described. Now-a-days, new materials for this type of implant could be considered due to novel and affordable manufacturing techniques. However, a factor of safety (FoS) should be considered. There are kinetic and kinematic studies of canine natural gaits, which can be used to establish an FoS for mechanical tests for new non-metallic devices. Polyetheretherketone (PEEK) is used in different specialties in human medicine. Its mechanical properties (and its close mechanical stiffness to that of bone) make this polymer an alternative to metals in veterinary traumatology. PEEK could also be used in 3D printing. The suitability of a novel inner part of an exo-endoprosthesis manufactured by fuse deposition modeling (FDM) was presented in this study for long canine bones. Mechanical characterization of 3D-printed PEEK material and ex vivo mechanical tests of a customized endoprosthesis were performed to address it. Young's modulus of 3D-printed PEEK suffered a reduction of 30% in relation to bulk PEEK. Customized 3D-printed PEEK endoprostheses had promising outcomes for the tibiae of 20 kg dogs. Pure compression tests of the non-inserted endoprostheses showed a maximum force of 936 ± 199 N. In the bending tests of non-inserted endoprostheses, the PEEK part remained intact. Quasistatic mechanical tests of bone-inserted endoprostheses (compression-bending and pure compression tests) reached a maximum force of 785 ± 101 N and 1,642 ± 447 N, respectively. In fatigue tests, the samples reached 500,000 cycles without failure or detriment to their quasistatic results. These outcomes surpass the natural weight-bearing of dogs, even during a galloping pace. In conclusion, the 3D-printed PEEK part of the endoprosthesis for an exo-endoprosthesis can withstand loading, even during a galloping pace.
- Open Access
- 26 August 2021
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 7
Test of Designing and Manufacturing a Polyether Ether Ketone Endoprosthesis for Canine Extremities by 3D Printing
Total limb amputation is quite common in small animals, although most of the indicated pathologies do not need such a restrictive procedure. Exo-endoprosthesis is a suggested alternative for the enhancement of the biomechanical situation of these patients. 3D printing of the internal part of exo-endoprostheses in polyether ether ketone (PEEK) is evaluated. Two different shapes of this internal part—one for radius’ and the other for cylindrical medullary cavities—were assessed. Proper PEEK temperature settings for 3D printing, the internal part of exo-endoprostheses, by fused filament fabrication (FFF) were obtained. Printing trials were carried out for different dimensions and printing orientation of these parts to achieve the best bone anchorage and thread strength outcomes. Pull-off strength tests for different surfaces of the internal part were performed with a best outcome for positive surfaces. All printed internal parts were inserted in canine tibiae and radii for an ex vivo assessment of bone anchorage and thread strength parameters. The best printing results were obtained at 410 and 130°C of the nozzle and bed temperatures, respectively. Also, a positive correlation was observed between the printing code, quality, and take-off time, while inverse correlation was shown between the take-off and the printing code, or quality, just like the print-bed temperature and the printing code. The positive surfaces had the best pull-off strength outcomes. Excellent bone anchorage and thread strength outcomes were obtained for one variant of each internal part shape. Designed devices had shown good threaded rod’s fitting inside the PEEK plug and perfect bone anchorage of the PEEK plug for tibiae and radii. In addition, iteration of manufacturing PEEK small devices by FFF technology has been shown due to small standard deviation of most variants.
- 26 August 2021
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 7
Open AccessTest of Designing and Manufacturing a Polyether Ether Ketone Endoprosthesis for Canine Extremities by 3D Printing
Total limb amputation is quite common in small animals, although most of the indicated pathologies do not need such a restrictive procedure. Exo-endoprosthesis is a suggested alternative for the enhancement of the biomechanical situation of these patients. 3D printing of the internal part of exo-endoprostheses in polyether ether ketone (PEEK) is evaluated. Two different shapes of this internal part—one for radius’ and the other for cylindrical medullary cavities—were assessed. Proper PEEK temperature settings for 3D printing, the internal part of exo-endoprostheses, by fused filament fabrication (FFF) were obtained. Printing trials were carried out for different dimensions and printing orientation of these parts to achieve the best bone anchorage and thread strength outcomes. Pull-off strength tests for different surfaces of the internal part were performed with a best outcome for positive surfaces. All printed internal parts were inserted in canine tibiae and radii for an ex vivo assessment of bone anchorage and thread strength parameters. The best printing results were obtained at 410 and 130°C of the nozzle and bed temperatures, respectively. Also, a positive correlation was observed between the printing code, quality, and take-off time, while inverse correlation was shown between the take-off and the printing code, or quality, just like the print-bed temperature and the printing code. The positive surfaces had the best pull-off strength outcomes. Excellent bone anchorage and thread strength outcomes were obtained for one variant of each internal part shape. Designed devices had shown good threaded rod’s fitting inside the PEEK plug and perfect bone anchorage of the PEEK plug for tibiae and radii. In addition, iteration of manufacturing PEEK small devices by FFF technology has been shown due to small standard deviation of most variants.