Koji Sudo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Koji Sudo has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Kenji Kuroki
Department of Cardiovascular Medicine University of Yamanashi Chuo Japan
15 shared publications - Akira Sato
Department of Cardiovascular Medicine, Faculty of Medicine, University of Yamanashi , 1110 Shimokato, Chuo, Yamanashi 409-3898
11 shared publications Akira Sato
10 shared publicationsTetsuya Asakawa
Department of Cardiology Yamanashi Kosei Hospital Yamanashi Japan
9 shared publicationsChisa Asahina
6 shared publications- Yasuteru Yamauchi
Department of Cardiology Yokohama City Minato Red Cross Hospital Yokohama Japan
6 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by Elsevier in HeartRhythm Case Reports
Acute defibrillation efficacy of right-sided implantation of a novel small-diameter lumenless defibrillation lead: A two-case series
- 23 October 2026
- Published by Elsevier in HeartRhythm Case Reports
Open AccessAcute defibrillation efficacy of right-sided implantation of a novel small-diameter lumenless defibrillation lead: A two-case series
- Open Access
- 21 October 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (5)
Vagal Response and Cough Reflex During Atrial Fibrillation Ablation Under Deep Sedation: A Comparison Across Pulsed Field Ablation Systems
Background: Pulsed field ablation (PFA) is increasingly used for atrial fibrillation (AF), but device‐specific autonomic and respiratory reflex responses remain insufficiently characterized. We aimed to compare vagal responses and cough reflexes among three commercially available PFA systems across individual pulmonary veins and the posterior wall. Methods: This retrospective single‐center study included 200 consecutive patients who underwent AF ablation with FARAPULSE ( n = 83), PULSESELECT ( n = 83), or VARIPULSE ( n = 34). Vagal response was operationally defined as bradyarrhythmia requiring temporary back‐up pacing during energy delivery. Cough reflex was assessed intraprocedurally at the left superior pulmonary vein (LSPV), left inferior pulmonary vein (LIPV), right superior pulmonary vein (RSPV), right inferior pulmonary vein (RIPV), and posterior wall. Results: Baseline characteristics were generally similar among groups, although heart failure and diabetes mellitus (DM) differed significantly. Overall vagal response rates did not differ among FARAPULSE, PULSESELECT, and VARIPULSE (61.4%, 67.5%, and 58.8%, respectively; p = 0.596). In contrast, overall cough reflex rates differed significantly (75.9%, 91.6%, and 55.9%; p < 0.001), driven by consistently higher rates with PULSESELECT. On logistic regression, male sex, body mass index, and use of PULSESELECT versus FARAPULSE were independently associated with cough reflex. Conclusions: Cough reflex was most frequent with PULSESELECT, whereas no significant difference in vagal response was observed among platforms. Recognizing these differences may improve procedural planning, sedation strategy, and prophylactic management during PFA.
- 21 October 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (5)
Open AccessVagal Response and Cough Reflex During Atrial Fibrillation Ablation Under Deep Sedation: A Comparison Across Pulsed Field Ablation Systems
Background: Pulsed field ablation (PFA) is increasingly used for atrial fibrillation (AF), but device‐specific autonomic and respiratory reflex responses remain insufficiently characterized. We aimed to compare vagal responses and cough reflexes among three commercially available PFA systems across individual pulmonary veins and the posterior wall. Methods: This retrospective single‐center study included 200 consecutive patients who underwent AF ablation with FARAPULSE ( n = 83), PULSESELECT ( n = 83), or VARIPULSE ( n = 34). Vagal response was operationally defined as bradyarrhythmia requiring temporary back‐up pacing during energy delivery. Cough reflex was assessed intraprocedurally at the left superior pulmonary vein (LSPV), left inferior pulmonary vein (LIPV), right superior pulmonary vein (RSPV), right inferior pulmonary vein (RIPV), and posterior wall. Results: Baseline characteristics were generally similar among groups, although heart failure and diabetes mellitus (DM) differed significantly. Overall vagal response rates did not differ among FARAPULSE, PULSESELECT, and VARIPULSE (61.4%, 67.5%, and 58.8%, respectively; p = 0.596). In contrast, overall cough reflex rates differed significantly (75.9%, 91.6%, and 55.9%; p < 0.001), driven by consistently higher rates with PULSESELECT. On logistic regression, male sex, body mass index, and use of PULSESELECT versus FARAPULSE were independently associated with cough reflex. Conclusions: Cough reflex was most frequent with PULSESELECT, whereas no significant difference in vagal response was observed among platforms. Recognizing these differences may improve procedural planning, sedation strategy, and prophylactic management during PFA.
- Open Access
- 27 May 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (3) , e70378
Efficacy of a Novel Ablation Index Algorithm for Cavotricuspid Isthmus Ablation Using a Flexible‐Tip Ablation Catheter
Introduction: AutoMark Index (AI) is a novel ablation algorithm integrating contact force (CF), radiofrequency (RF) current, and application duration to provide real‐time lesion formation feedback. Data of AI using a flexible‐tip RF ablation catheter for cavotricuspid isthmus (CTI) ablation remain limited. The objective was to evaluate the efficacy and safety of AI‐guided CTI ablation. Methods: Consecutive 148 patients undergoing CTI ablation with a CF‐sensing flexible‐tip ablation catheter were included. Outcomes using an AI‐guided protocol (50 W, targeting AI of 50; AI‐50 group, 62 patients) were compared with a conventional protocol (40 W for 20 s; 40‐W group, 86 patients). Results: The first‐line success rate showed no difference between the two groups (40‐W group: 72/86 [84.7%] vs. AI‐50 group: 51/62 [82.2%], p = 0.81). The total RF application showed no difference (40‐W group: 12 [9.5–15] vs. AI‐50 group: 12 [9.7–16], p = 0.50); however, significant differences were observed in the total RF duration (40‐W group: 274 [211–372] s vs. AI‐50 group: 180 [138–249] s, p < 0.001), the RF duration for initial block (40‐W group: 225 [163–323] s vs. AI‐50 group: 149 [109–221] s, p < 0.001), and CTI procedural time (40‐W group: 9.2 [6.0–14.6] min vs. AI‐50 group: 6.3 [4.5–9.7] min, p = 0.007). No significant differences were observed in the mean CF, average temperature, and CTI length between the two groups. No major complications were observed in either of the groups. Conclusion: AI‐guided CTI ablation protocol is efficient in shortening RF duration for acute bidirectional CTI block and CTI procedure time compared to the conventional 40 W ablation protocol.
- 27 May 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (3) , e70378
Open AccessEfficacy of a Novel Ablation Index Algorithm for Cavotricuspid Isthmus Ablation Using a Flexible‐Tip Ablation Catheter
Introduction: AutoMark Index (AI) is a novel ablation algorithm integrating contact force (CF), radiofrequency (RF) current, and application duration to provide real‐time lesion formation feedback. Data of AI using a flexible‐tip RF ablation catheter for cavotricuspid isthmus (CTI) ablation remain limited. The objective was to evaluate the efficacy and safety of AI‐guided CTI ablation. Methods: Consecutive 148 patients undergoing CTI ablation with a CF‐sensing flexible‐tip ablation catheter were included. Outcomes using an AI‐guided protocol (50 W, targeting AI of 50; AI‐50 group, 62 patients) were compared with a conventional protocol (40 W for 20 s; 40‐W group, 86 patients). Results: The first‐line success rate showed no difference between the two groups (40‐W group: 72/86 [84.7%] vs. AI‐50 group: 51/62 [82.2%], p = 0.81). The total RF application showed no difference (40‐W group: 12 [9.5–15] vs. AI‐50 group: 12 [9.7–16], p = 0.50); however, significant differences were observed in the total RF duration (40‐W group: 274 [211–372] s vs. AI‐50 group: 180 [138–249] s, p < 0.001), the RF duration for initial block (40‐W group: 225 [163–323] s vs. AI‐50 group: 149 [109–221] s, p < 0.001), and CTI procedural time (40‐W group: 9.2 [6.0–14.6] min vs. AI‐50 group: 6.3 [4.5–9.7] min, p = 0.007). No significant differences were observed in the mean CF, average temperature, and CTI length between the two groups. No major complications were observed in either of the groups. Conclusion: AI‐guided CTI ablation protocol is efficient in shortening RF duration for acute bidirectional CTI block and CTI procedure time compared to the conventional 40 W ablation protocol.
- Open Access
- 12 March 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (15) , 107285
Role of Endomyocardial Biopsy and Bachmann's Bundle Pacing for Sinus Node Dysfunction in Cardiac Amyloidosis
- 12 March 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (15) , 107285
Open AccessRole of Endomyocardial Biopsy and Bachmann's Bundle Pacing for Sinus Node Dysfunction in Cardiac Amyloidosis
- 13 January 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (4) , 480-484
Complex Signal Identification Map for Optimal Ablation Site in Slow‐Fast Atrioventricular Nodal Reentrant Tachycardia
Slow pathway (SP) ablation is an established therapy for slow‐fast atrioventricular nodal reentrant tachycardia (AVNRT), with high success and low recurrence rates. We report a case in which a complex signal identification (CSI) map with the CARTO system was used during slow‐fast AVNRT to localize a fractionated region near the coronary sinus ostium that coincided with the successful SP ablation site.
- 13 January 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (4) , 480-484
Complex Signal Identification Map for Optimal Ablation Site in Slow‐Fast Atrioventricular Nodal Reentrant Tachycardia
Slow pathway (SP) ablation is an established therapy for slow‐fast atrioventricular nodal reentrant tachycardia (AVNRT), with high success and low recurrence rates. We report a case in which a complex signal identification (CSI) map with the CARTO system was used during slow‐fast AVNRT to localize a fractionated region near the coronary sinus ostium that coincided with the successful SP ablation site.
- Open Access
- 19 September 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (11) , 3024-3032
Visualization of Real‐Time Esophageal Location Using Intracardiac Echocardiography on a Three‐Dimensional Mapping System: Comparison of Esophageal Location Using Preoperative Computed Tomography and Investigation of Predictors for Esophageal Movement During Catheter Ablation
Introduction: Pulmonary vein isolation (PVI) using radiofrequency catheter ablation is an effective treatment for atrial fibrillation; however, esophageal‐related complications remain a concern. The first objective of this study was to compare the feasibility of two techniques for visualizing real‐time esophageal images: intracardiac echocardiography (ICE‐Eso) and preoperative computed tomography (CT‐Eso). The second objective was to clarify the predictors of esophageal movement on the day of catheter ablation. Methods and Results: Eighty consecutive patients were included in this study. The esophageal location was measured at the centerline of each image on three equally separated imaging sections (upper, middle, and lower sites). Esophageal locations detected on ICE‐Eso and CT‐Eso were compared with those on contrast esophagography. We also investigated predictors of esophageal movement. A significant difference was found between the two distances in all three sections: upper site (ICE‐Eso: 2.5 [interquartile range (IQR) 1.4–3.6] mm vs. CT‐Eso: 5.2 [IQR 3.4–7.6] mm, p < 0.001), middle site (ICE‐Eso: 2.7 [IQR 1.3–4.3] mm vs. CT‐Eso: 5.4 [IQR 3.2–8.3] mm, p < 0.001), and lower site (ICE‐Eso: 2.8 [IQR 1.2–5.2] mm vs. CT‐Eso: 5.8 [IQR 3.1–10.3] mm, p < 0.001). Multivariate analysis revealed that eating a meal on the morning on the day of catheter ablation (non‐fasting) was a predictor of esophageal movement. One patient (1.2%) experienced gastric hypomotility, which resolved completely with medical treatment. Conclusion: The results showed that ICE‐Eso provided real‐time, accurate esophageal location compared to CT‐Eso. Therefore, ICE‐Eso‐guided PVI on the left atrial posterior wall near the esophagus may be a safe method. Additionally, non‐fasting on the day of catheter ablation could help to predict esophageal movement.
- 19 September 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (11) , 3024-3032
Open AccessVisualization of Real‐Time Esophageal Location Using Intracardiac Echocardiography on a Three‐Dimensional Mapping System: Comparison of Esophageal Location Using Preoperative Computed Tomography and Investigation of Predictors for Esophageal Movement During Catheter Ablation
Introduction: Pulmonary vein isolation (PVI) using radiofrequency catheter ablation is an effective treatment for atrial fibrillation; however, esophageal‐related complications remain a concern. The first objective of this study was to compare the feasibility of two techniques for visualizing real‐time esophageal images: intracardiac echocardiography (ICE‐Eso) and preoperative computed tomography (CT‐Eso). The second objective was to clarify the predictors of esophageal movement on the day of catheter ablation. Methods and Results: Eighty consecutive patients were included in this study. The esophageal location was measured at the centerline of each image on three equally separated imaging sections (upper, middle, and lower sites). Esophageal locations detected on ICE‐Eso and CT‐Eso were compared with those on contrast esophagography. We also investigated predictors of esophageal movement. A significant difference was found between the two distances in all three sections: upper site (ICE‐Eso: 2.5 [interquartile range (IQR) 1.4–3.6] mm vs. CT‐Eso: 5.2 [IQR 3.4–7.6] mm, p < 0.001), middle site (ICE‐Eso: 2.7 [IQR 1.3–4.3] mm vs. CT‐Eso: 5.4 [IQR 3.2–8.3] mm, p < 0.001), and lower site (ICE‐Eso: 2.8 [IQR 1.2–5.2] mm vs. CT‐Eso: 5.8 [IQR 3.1–10.3] mm, p < 0.001). Multivariate analysis revealed that eating a meal on the morning on the day of catheter ablation (non‐fasting) was a predictor of esophageal movement. One patient (1.2%) experienced gastric hypomotility, which resolved completely with medical treatment. Conclusion: The results showed that ICE‐Eso provided real‐time, accurate esophageal location compared to CT‐Eso. Therefore, ICE‐Eso‐guided PVI on the left atrial posterior wall near the esophagus may be a safe method. Additionally, non‐fasting on the day of catheter ablation could help to predict esophageal movement.
- 2 August 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
Non‐Occlusive Separate Freezing for Cryoballoon Pulmonary Vein Isolation to the Large Pulmonary Vein
Background: Cryoballoon pulmonary vein (PV) isolation (PVI) requires PV occlusion, which can be challenging to the large PV. The non‐occlusive separate freezing, which involves freezing the superior and inferior portions of the PV ostium without complete occlusion, is often useful in these situations. This study aimed to evaluate the efficacy and long‐term results of the non‐occlusive separate freezing technique and compare the treatment details of POLARx and Arctic Front Advance Pro (AFA‐Pro).Methods: Patients who underwent cryoballoon PVI using the non‐occlusive separate freezing between September 2019 and April 2023 in our institution were analyzed and followed up for 1 year. Success rates of PVI by non‐occlusive separate freezing and treatment outcomes were compared between POLARx and AFA‐Pro. The 1‐year arrhythmia‐free survival was also evaluated.Results: Overall, 135 PVs were analyzed (POLARx, n = 63; and AFA‐Pro, n = 72). The success rates of PVI for the POLARx and AFA‐Pro were 55/63 (87.3%) and 52/72 (72.2%), p = 0.04. The nadir temperatures for the POLARx and AFA‐Pro were −52.2 ± 4.7°C and −42.4 ± 7.4°C, p < 0.001. No phrenic nerve injury occurred in either group, but two cases of gastric hypomotility were observed using POLARx. The 1‐year arrhythmia‐free survival rates for POLARx and AFA‐Pro were 86.4% and 81.2%, p = 0.47.Conclusions: The success rate of PVI using the non‐occlusive separate freezing technique was approximately 80% and was significantly higher with POLARx than with AFA‐Pro. The 1‐year arrhythmia‐free survival rate was not significantly different.
- 2 August 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
Non‐Occlusive Separate Freezing for Cryoballoon Pulmonary Vein Isolation to the Large Pulmonary Vein
Background: Cryoballoon pulmonary vein (PV) isolation (PVI) requires PV occlusion, which can be challenging to the large PV. The non‐occlusive separate freezing, which involves freezing the superior and inferior portions of the PV ostium without complete occlusion, is often useful in these situations. This study aimed to evaluate the efficacy and long‐term results of the non‐occlusive separate freezing technique and compare the treatment details of POLARx and Arctic Front Advance Pro (AFA‐Pro).Methods: Patients who underwent cryoballoon PVI using the non‐occlusive separate freezing between September 2019 and April 2023 in our institution were analyzed and followed up for 1 year. Success rates of PVI by non‐occlusive separate freezing and treatment outcomes were compared between POLARx and AFA‐Pro. The 1‐year arrhythmia‐free survival was also evaluated.Results: Overall, 135 PVs were analyzed (POLARx, n = 63; and AFA‐Pro, n = 72). The success rates of PVI for the POLARx and AFA‐Pro were 55/63 (87.3%) and 52/72 (72.2%), p = 0.04. The nadir temperatures for the POLARx and AFA‐Pro were −52.2 ± 4.7°C and −42.4 ± 7.4°C, p < 0.001. No phrenic nerve injury occurred in either group, but two cases of gastric hypomotility were observed using POLARx. The 1‐year arrhythmia‐free survival rates for POLARx and AFA‐Pro were 86.4% and 81.2%, p = 0.47.Conclusions: The success rate of PVI using the non‐occlusive separate freezing technique was approximately 80% and was significantly higher with POLARx than with AFA‐Pro. The 1‐year arrhythmia‐free survival rate was not significantly different.