Seong-Kyun Cheong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seong-Kyun Cheong has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Jong-Seol Jeong
Graduate School of NID Fusion Technology, Seoul National University of Science and Technology, Seoul, Korea
2 shared publicationsYong-Sung Lee
Seoul National University of Science and Technology
2 shared publications- Junji Sakamoto
Faculty of Environmental, Life, Natural Science and Technology Okayama University Okayama Japan
1 shared publication Seung-Hwan Lee
Machinery, Metals and Construction Examinations Bureau, Korean Intellectual Property Office, Republic of Korea
1 shared publication
Latest Publications
- 20 September 2014
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 28 (9) , 3555-3560
Effect of shot peening coverage on fatigue limit in round bar of annealed medium carbon steel
- 20 September 2014
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 28 (9) , 3555-3560
Effect of shot peening coverage on fatigue limit in round bar of annealed medium carbon steel
- 28 December 2013
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 27 (12) , 3651-3656
Interlaminar fracture toughness of CFRP laminates with silk fibers interleave
- 28 December 2013
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 27 (12) , 3651-3656
Interlaminar fracture toughness of CFRP laminates with silk fibers interleave
- 3 October 2012
- Published by SAGE Publications in Journal of Composite Materials
- Vol. 47 (15) , 1865-1875
Interlaminar fracture toughness characteristics of hybrid laminates with nonwoven carbon tissue under severe temperature conditions
To investigate the Mode I and Mode II interlaminar fracture toughness characteristics of hybrid laminates with nonwoven carbon tissue under severe temperature conditions, double cantilever beam and end notched flexure tests were conducted. The hybrid laminates were made by interleaving the NWCT-prepreg between the CFRP-prepreg layers. The mean GIC values of the hybrid specimens at +60℃ and +80℃ were about 19% and 92% higher than those of the carbon fiber reinforced polymer specimens at +60℃ and +80℃, respectively. The mean GIC values of the hybrid specimens increased due to the carbon short-fibers bridging and breakage by softening of epoxy resin in the nonwoven carbon tissue layer (NWCT) as the temperature rises. The mean GIIC values of the hybrid specimens at −60℃ to +80℃ were about 171% to 189% higher than those of the CFRP specimens at −60℃ to +80℃, respectively. When the decreasing rate (the mean GIIC value of the CFRP specimen at +80℃ was about 18% lower than that of the CFRP specimen at room temperature.) of the mean GIIC values of the CFRP specimens at +80℃ was compared, the decreasing rate (the mean GIIC value of the hybrid specimen at +80℃ was about 9% lower than that of the hybrid specimen at room temperature.) of the mean GIIC values of the hybrid specimens at +80℃ slowed down significantly due to the carbon short-fibers bridging, carbon short-fibers breakage and hackles. Consequently, the mean GIIC values of the hybrid specimens in the range of −60℃ to +80℃ have no significant influence on softening of epoxy resin.
- 3 October 2012
- Published by SAGE Publications in Journal of Composite Materials
- Vol. 47 (15) , 1865-1875
Interlaminar fracture toughness characteristics of hybrid laminates with nonwoven carbon tissue under severe temperature conditions
To investigate the Mode I and Mode II interlaminar fracture toughness characteristics of hybrid laminates with nonwoven carbon tissue under severe temperature conditions, double cantilever beam and end notched flexure tests were conducted. The hybrid laminates were made by interleaving the NWCT-prepreg between the CFRP-prepreg layers. The mean GIC values of the hybrid specimens at +60℃ and +80℃ were about 19% and 92% higher than those of the carbon fiber reinforced polymer specimens at +60℃ and +80℃, respectively. The mean GIC values of the hybrid specimens increased due to the carbon short-fibers bridging and breakage by softening of epoxy resin in the nonwoven carbon tissue layer (NWCT) as the temperature rises. The mean GIIC values of the hybrid specimens at −60℃ to +80℃ were about 171% to 189% higher than those of the CFRP specimens at −60℃ to +80℃, respectively. When the decreasing rate (the mean GIIC value of the CFRP specimen at +80℃ was about 18% lower than that of the CFRP specimen at room temperature.) of the mean GIIC values of the CFRP specimens at +80℃ was compared, the decreasing rate (the mean GIIC value of the hybrid specimen at +80℃ was about 9% lower than that of the hybrid specimen at room temperature.) of the mean GIIC values of the hybrid specimens at +80℃ slowed down significantly due to the carbon short-fibers bridging, carbon short-fibers breakage and hackles. Consequently, the mean GIIC values of the hybrid specimens in the range of −60℃ to +80℃ have no significant influence on softening of epoxy resin.