WPWooyul Paik

Wooyul Paik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wooyul Paik has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ultrasound Pattern-Based Malignancy Risk Stratification and Subcategorization of K-TIRADS Intermediate-Suspicion Thyroid Nodules to Improve Biopsy Decision-Making

    by Boeun Lee, Byeong-Joo Noh, Wooyul Paik, Dong Gyu Na

    Lee B, et al. Korean J Radiol. 2026 Nov;27(11):1094-1104. https://doi.org/10.3348/kjr.2026.0027

  • Open Access

    Ultrasonographic features of normal parathyroid glands confirmed during thyroid surgery in adult patients

    by Seong Ju Kim, Wooyul Paik, Jong Cheol Lee, Yong Jin Song, Kwanghyun Yoon, Byeong-Joo Noh, Dong Gyu Na

    Purpose: This study was performed to examine the ultrasonography (US) features of normal parathyroid glands (PTGs) that were identified on preoperative US and subsequently confirmed during thyroid surgery.Methods: This retrospective study included a consecutive sample of 161 patients (mean±standard deviation age, 56±14 years; 128 women) with 294 normal PTGs identified on preoperative US PTG mapping and confirmed during thyroidectomy. A presumed normal PTG on US was defined as a small, round to oval, hyperechoic structure in the central neck. These presumed normal PTGs, as identified on preoperative US, were mapped onto thyroid computed tomography images and diagrams of the thyroid gland and neck. During the preoperative real-time US examinations, the location, size, shape, echogenicity, echotexture, and intraglandular vascular flow of the identified presumed PTGs were assessed. These characteristics were compared between superior and inferior PTGs using the generalized estimating equation method.Results: The typical US features of homogeneous hyperechogenicity without intraglandular vascular flow were observed in 267 (90.8%) normal PTGs, while atypical features, including isoechogenicity (1.0%), heterogeneous echotexture with focal hypoechogenicity (5.8%), and intraglandular vascular flow (3.7%), were noted in 27 (9.2%). Inferior PTGs were more frequently identified in posterolateral (36.1% vs. 5.3%) and thyroid pole locations (29.9% vs. 5.3%), and less frequently in posteromedial locations (29.2% vs. 88.0%), compared to superior PTGs (P<0.001 for each comparison).Conclusion: Most normal PTGs displayed the typical US features of homogeneous hyperechogenicity without intraglandular vascular flow. However, in rare cases, normal PTGs exhibited atypical features, including isoechogenicity, heterogeneous echotexture with focal hypoechogenicity, and intraglandular vascular flow.


  • Open Access

    US Features of the Parathyroid Glands: An Intraoperative Surgical Specimen Study

    by Wooyul Paik, Jong Cheol Lee, Byeong-Joo Noh, Dong Gyu Na

    백우열, et al. J Korean Soc Radiol. 2023 Apr;84:e43. https://doi.org/10.3348/jksr.2022.0104


  • Open Access

    Emergency triage of brain computed tomography via anomaly detection with a deep generative model

    by Seungjun Lee, Boryeong Jeong, Minjee Kim, Ryoungwoo Jang, Wooyul Paik, Jiseon Kang, Won Jung Chung, Gil-Sun Hong, Namkug Kim

    Triage is essential for the early diagnosis and reporting of neurologic emergencies. Herein, we report the development of an anomaly detection algorithm (ADA) with a deep generative model trained on brain computed tomography (CT) images of healthy individuals that reprioritizes radiology worklists and provides lesion attention maps for brain CT images with critical findings. In the internal and external validation datasets, the ADA achieved area under the curve values (95% confidence interval) of 0.85 (0.81–0.89) and 0.87 (0.85–0.89), respectively, for detecting emergency cases. In a clinical simulation test of an emergency cohort, the median wait time was significantly shorter post-ADA triage than pre-ADA triage by 294 s (422.5 s [interquartile range, IQR 299] to 70.5 s [IQR 168]), and the median radiology report turnaround time was significantly faster post-ADA triage than pre-ADA triage by 297.5 s (445.0 s [IQR 298] to 88.5 s [IQR 179]) (all p < 0.001).


  • Open Access

    Epipericardial Fat Necrosis in a Pediatric Patient Diagnosed Using Contrast-Enhanced MRI Findings: A Case Report and Literature Review

    by Seong Ju Kim, Byoung Hee Han, Youngjong Cho, Dae Shick Ryu, Ga Young Yoon, Wooyul Paik, Young Rae Kim

    김승주, et al. J Korean Soc Radiol. 2022 Apr;83:e47. https://doi.org/10.3348/jksr.2021.0157


  • Open Access

    Comparison of the diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System for thyroid malignancy with three international guidelines

    by Eun Ju Ha, Jung Hee Shin, Dong Gyu Na, So Lyung Jung, Young Hen Lee, Wooyul Paik, Min Ji Hong, Yeo Koon Kim, Chang Yoon Lee

    Purpose: This study compared the diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System (K-TIRADS) for thyroid malignancy with three international guidelines.Methods: From June to September 2015, 5,708 thyroid nodules (≥1.0 cm) in 5,081 consecutive patients who underwent thyroid ultrasound (US) at 26 institutions were evaluated. The US features of the thyroid nodules were retrospectively reviewed and classified according to all four guidelines. In the modified K-TIRADS, the biopsy size threshold was changed to 2.0 cm for K-TIRADS 3 and 1.0 or 1.5 cm for K-TIRADS 4 (K-TIRADS1.0cm and K-TIRADS1.5cm, respectively). We compared the diagnostic performance and unnecessary fine-needle aspiration biopsy (FNAB) rates for thyroid malignancy between the modified K-TIRADS and three international guidelines.Results: Of the 5,708 thyroid nodules, 4,597 (80.5%) were benign and 1,111 (19.5%) were malignant. The overall sensitivity was highest for the modified K-TIRADS1.0cm (91.0%), followed by the European (EU)-TIRADS (84.6%), American Association of Clinical Endocrinologists/American College of Endocrinology/Associazione Medici Endocrinologi (AACE/ACE/AME) (80.5%), American College of Radiology (ACR)-TIRADS (76.1%), and modified K-TIRADS1.5cm (76.1%). For large nodules (>2.0 cm), the sensitivity increased to 98.0% in both the modified K-TIRADS1.0cm and K-TIRADS1.5cm. For small nodules (≤2.0 cm), the unnecessary FNAB rate was lowest with the modified K-TIRADS1.5cm (17.6%), followed by the ACR-TIRADS (18.6%), AACE/ACE/AME (19.3%), EU-TIRADS (28.1%), and modified K-TIRADS1.0cm (31.2%).Conclusion: The modified K-TIRADS1.5cm can reduce the unnecessary FNAB rate for small nodules (1.0-2.0 cm), while maintaining high sensitivity for detecting malignancies >2.0 cm.


  • Open Access

    Diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System for thyroid malignancy according to nodule size: a comparison with five society guidelines

    by Dong Gyu Na, Wooyul Paik, Jaehyung Cha, Hye Yun Gwon, Suh Young Kim, Roh-Eul Yoo

    Purpose: The aim of this study was to evaluate the diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System (K-TIRADS) compared with five society risk stratification systems (RSSs) according to nodule size.Methods: In total, 3,826 consecutive thyroid nodules (≥1 cm) with final diagnoses in 3,088 patients were classified according to five RSSs. The K-TIRADS was modified by raising the biopsy size threshold for low-suspicion nodules and subcategorizing intermediate-suspicion nodules. We assessed the performance of the RSSs as triage tests and their diagnostic accuracy according to nodule size (with a threshold of 2 cm).Results: Of all nodules, 3,277 (85.7%) were benign and 549 (14.3%) were malignant. In small thyroid nodules (≤2 cm), the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) had the highest reduction rate of unnecessary biopsies (76.3%) and the lowest sensitivity (76.1%). The modified K-TIRADS had the second highest reduction rate of unnecessary biopsies (67.6%) and sensitivity (86.6%). The modified K-TIRADS and ACR TI-RADS had the highest diagnostic odds ratios (P=0.165) and the highest areas under the curve (P=0.315). In large nodules (>2 cm), the sensitivity of the ACR TI-RADS for malignancy was significantly lower (88.8%) than the sensitivities of the modified K-TIRADS and other RSSs, which were very high (98.7%-99.3%) (P<0.001).Conclusion: The modified K-TIRADS allows a large proportion of unnecessary biopsies to be avoided, while maintaining high sensitivity and diagnostic accuracy for small malignant tumors and very high sensitivity for large malignant tumors.


  • Open Access

    Ultrasonographic echogenicity of normal salivary glands in adults: comparison of submandibular and parotid glands

    by Insik Choi, Dong Gyu Na, Wooyul Paik

    The normal submandibular gland (SMG) and parotid gland (PG) are thought to have similar homogeneous ultrasound (US) hyperechogenicity; however, this has not been extensively investigated. The aim of this study was to determine whether the normal SMG and PG have similar US echogenicity. We included 969 consecutive adult patients with normal salivary glands. The patients were categorized into three age groups: group 1 (19 to 29 years, n=27), group 2 (30 to 49 years, n=273), and group 3 (≥50 years, n=669). The echogenicities of the SMG and PG were prospectively evaluated by an experienced radiologist. Computed tomography (CT) attenuation in Hounsfield units (HUs) was quantitatively measured for the SMG, PG, and sternocleidomastoid muscle in 140 patients. Relative to the PG, the echogenicity of the SMG was similar in 706 (73.0%) and homogeneously hypoechoic in 263 patients (27.0%). The frequency of SMG hypoechogenicity decreased with increasing age (group 1, 59.3%; group 2, 36.3%; group 3, 22.1%; P<0.001). The CT attenuation levels (in HUs) of the SMG and PG were significantly higher in patients with hypoechoic SMGs than in patients with SMG echogenicity similar to that of the PG (P<0.001). Hypoechogenicity of the SMG was observed in approximately one-third of this sample of adults with normal salivary glands. The SMG may be inadequate as a reference standard for evaluating thyroid nodule echogenicity in patients with diffuse thyroid disease with decreased echogenicity.


  • Open Access

    Clinical Features and Brain MRI Findings in Korean Patients with AGel Amyloidosis

    by E-Nae Cheong, Wooyul Paik, Young-Chul Choi, Young-Min Lim, Hyunjin Kim, Woo Hyun Shim, Hyung Jun Park

    Cheong EN, et al. Yonsei Med J. 2021 May;62(5):431-438. https://doi.org/10.3349/ymj.2021.62.5.431


  • Open Access

    Malignancy Risk Stratification of Thyroid Nodules with Macrocalcification and Rim Calcification Based on Ultrasound Patterns

    by Hwa Seon Shin, Dong Gyu Na, Wooyul Paik, So Jin Yoon, Hye Yun Gwon, Byeong-Joo Noh, Won Jun Kim

    Shin HS, et al. Korean J Radiol. 2021 Apr;22(4):663-671. https://doi.org/10.3348/kjr.2020.0381